Fig. 8.3. Air distributor for firewood logs, timber waste, sawdust briquettes.
8.2.
The operation method of this regulator is based that when the body of the boiler becomes
warmed - it expands, the body itself slightly close or close a valve (1) through a lever (4) and when
getting cooler - shrinks and opens (fig. 8.5.).
When the boiler is brought into a boiler room and is connected to the pipeline of the heating
system, take off a transportation strip and check whether draught regulating parts are not deformed:
support bar (3) mount on the boiler, the emboss of its metal part (5) must be in the valve lever (4) pore
and the temperature setting screw (2) spike - in the sag of a lever (4). The sag and pore are near each
other at the distance of 3.5 mm.
Fig. 8.4.Tubular air distributor for coal or peat briquettes.
SETTING OF THE BI-THERMAL DRAUGHT REGULATOR
15