Notes
Refer to the mixing valve manufacturer's
instructions supplied with the valve for
further information. Put these with this
manual.
The mixing valve is not guaranteed against
corrosion or blockage caused by excessive
scale.
FROM
CYLINDER
SERVICE VALVE
4 4 4 4 4
VALVE CAN BE POSITIONED IN
ANY ORIENTATION
4-4

Heating System

24
4-3.9 Thermostatic Mixing Valve
A Thermostatic Mixing Valve is supplied with the Electrastream. It should be fitted
between the cylinder hot water outlet and the draw off (taps). The valve mixes hot water
from the cylinder with cold water to provide hot water at the taps at a consistent
temperature.
The valve is supplied with two check valves which must be fitted to the hot and cold
supply.
It is recommended to fit a service valve on each of the three pipes to the valve.
CHECK VALVE
M I X
SERVICE VALVE
SERVICE VALVE
DRAW OFF (TAPS)
Fig. 4-3d Thermostatic Mixing Valve
Fig. 4-4a Schematic of Typical Heating System
CHECK VALVE
COLD
SUPPLY
CHECK VALVE
INST
INSTALLA
INST
INST
INST
ALLA
ALLA
ALLA
ALLATION
TION
TION
TION
TION
CHECK VALVE
HOT OR COLD AS
MARKED
MIX - CONNECTED TO
DRAW OFF (TAPS)
4
4
4
4
4