Option Settings - Garrison 52-2544-0 Installation Manual

7 day programmable thermostat for electric baseboards and radiant heating
Table of Contents

Advertisement

OPTION SETTINGS

This thermostat has 4 OPTION settings which the user can change.
The OPTION data will appear in the lower pane of the LCD screen.
OPTION 1 - 12 or 24 Hour Clock Format
Press and hold OPTION/COPY for 3 seconds to enter the Option Setting mode.
1
The first option is 12 or 24 hour clock format. (12:Hr will be flashing)
Press UP or DOWN to toggle between 12 or 24 hour format.
2
OPTION 2 - Heat Cycle Rate
Press OPTION/COPY again to advance to the second option (Cycle rate. Cr:1 will flash)
1
Press UP or DOWN button to adjust setting (see cycle rate definition on following pages)
2
Cr0 = Full Power, No Cycle (for fan assisted baseboards and electric heating devices)
Cr1 = 20 Sec. Proportional Power (for non-fan assisted baseboards and electric heating devices)
Cr2 = 240 Sec. Proportional Power (for fan assisted heaters and radiant floor/ceiling)
OPTION 3 - Pre-Comfort Recovery
Press OPTION/COPY again to select pre-comfort recovery. (rE:0 will flash on screen)
1
Press UP or DOWN to adjust setting (see pre-comfort recovery definition on following pages)
2
rE:0 means pre-comfort recovery feature is disabled
rE:1 means pre-comfort recover
y feature is enabled
22
OPTION

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Garrison 52-2544-0

Table of Contents