Table 21: Description event protocol ....................... 32 Introduction The IP-EFOY-GATEWAY serves for remote control of a single SFC EFOY PRO fuel cell over the TCP/IP protocol. At this the entire fuel cell parameter defined by the SFC EFOY PRO technical data sheet are readout continu- ously over the RS232 interface.
Firmware update description V0.8.3 • Firmware supports now SFC EFOY PRO 800/800 DUO and 2400/2400DUO • Dynamic web data update interval on the web site can be adapted V0.7.1 • Firmware supports now SFC EFOY PRO v11.10 with CONFIG command adaptation, but also back- ward compatibility is assured V0.6.7 •...
Technical Data Data Range Comment Power consumption • Input voltage range 8V - 42V Allowed with 12V/24V batteries • Power supply on terminal block and over EFOY PRO data interface as well • Ethernet 10/100BASE-T IEEE802.2 compatibility • RS232 (1 port) Communication EFOY PRO with 9600 Baud Table 1: Electrical Data Data...
IP Configuration The following 5 shows the default settings of the IP-EFOY-GATEWAY. By pressing the „Default“ switch button 5 seconds (see Figure 1) you can restore the default setting. DHCP Enabled since firmware version v0.6.7 IP address 192.168.96.210 Subnet mask 255.255.255.0...
Description Periphery Front panel Figure 1: Front panel Power supply on 1Hz heart beat, system Data communication EFOY Pro ↔ IP-EFOY-GATEWAY Not used Default Switch button must be pressed > 5 seconds, to restore default setting RS232 Communication IP-EFOY-GATEWAY ↔ EFOY PRO •...
Supported Protocols Protocol Comment • HTTP Configuration • Fuel cell states • DCHP Client Automatic IP configuration • SNMP v2c Remote control EFOY PRO • SMTP Email notification service • Protocol stack EFOY PRO Communication with EFOY PRO over RS232 •...
Getting started Figure 3 depicts schematically the cabling diagram of the IP-EFOY-GATEWAY to other communication devices and EFOY PRO periphery. Figure 3: Schematic Installation AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405...
As a start please follow the following steps to set up the network configuration properly. The IP-EFOY- GATEWAY's default IP-Address is “192.168.96.210”. Use your browser on initial installation or after a default reset to access IP-EFOY-GATEWAY's web server. First you have to set up network settings to be conform with your local network.
Open the browser and enter the default IP address of the IP-EFOY-GATEWAY (see Figure 7). Figure 6: Login IP-EFOY-GATEWAY website Choose menu item “IP” on the left of the website and enter the default login and password com- bination (see Figure 6 - Default user name: “admin” and default password: “00000”) Afterwards choose new static IP-Configuration for your given network (see Figure 7).
Off grid power supply for wireless internet service provider (3.5 / 5 GHz base stations) Figure 10: Pilot project - Off grid power supply for internet service provider AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 mail@awilco-multiplex.dk | www.awilco-multiplex.dk...
MAC address IP-EFOY-GATEWAY • Host name IP-EFOY-GATEWAY • DHCP client service enabled/disabled • IP address IP-EFOY-GATEWAY (automatic bound via DHCP) • Gateway in LAN (automatic bound via DHCP) • Subnet mask (automatic bound via DHCP) • Primary DNS Server (automatic bound via DHCP) •...
10.4 Web site - SNMP Figure 14: Web site - SNMP Note Description • System name (may be readout via SNMP default OID) • System location (may be readout via SNMP default OID) • System contact (may be readout via SNMP default OID) •...
Note Description • Battery protection – nevertheless the EFOY will charge the battery if the battery voltage fall below the configured voltage and the EFOY operating mode is set to “OFF”, to prevent deep discharge • Selection of EFOY operating mode •...
10.6 Web site - EFOY Setup The EFOY setup overview makes it possible to set up EFOY PRO fuel cell's configuration. The entire configu- ration is described analogue to the EFOY “Config” request. Some options differ from 1 to 2 EFOY PRO generation.
Figure 18: Web site – 2 generation EFOY Setup Note Description • EFOY switch on voltage for 12V systems in mV • EFOY switch off voltage for 12V systems in mV • EFOY switch off voltage 12V systems in mA •...
Green = IP-EFOY-GATEWAY synchronized with EFOY • Red = IP-EFOY-GATEWAY not synchronized with EFOY • Green = IP-EFOY-GATEWAY no errors on processing EFOY data • Red = IP-EFOY-GATEWAY errors on processing EFOY data • Current EFOY battery voltage in V •...
Note Description • Temperature at the stack • Temperature in the fuel cell • Temperature at the heat exchanger • Green = methanol level above sensor threshold or no sensor connected • Red = methanol level below sensor threshold • DuoCartSwitch state •...
10.9 Web site - Info Figure 21: Web site – 1 generation EFOY Info Figure 22: Web site – 2 generation EFOY Info AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 mail@awilco-multiplex.dk | www.awilco-multiplex.dk...
Note Description • Device type IP-EFOY-GATEWAY • Version firmware and hardware • Version web site image • Version TCP/IP Stack • Compile date • Link Web site Ingenieurbuero Piwek • Link Email to Ingenieurbuero Piwek • Connected EFOY will be determined automatically •...
10.10 Email Notification Service From firmware versions v0.6.1 on, the IP-EFOY-GATEWAY supports an email notification service to deliver EFOY PRO events and warnings to an email address. From now on service personnel get real-time email fault reports on their smart phone or email account. The service is set up the easy way over the website menu “Notification”...
In the following 21 the email notification configuration is described. Field name Description Option Notification Enabled Enables the email notification service mandatory SMTP Server SMTP server used for email delivery. Please consult mandatory your administrator or email provider. Port Port number of the SMTP server. Please consult your mandatory administrator or email provider.
Figure 27 depicts all fetched fault report emails in the area marked with „1“. Area „2“ shows the delivered IP-EFOY-GATEWAY emails with the fault report in more detail. 22 illustrates the email fields and the single rows of the fault report. Email subject: IP-EFOY-GATEWAY ALERT.
Remote control over a command line interface is also possible. Figure 26 depicts the opportunity how to establish a remote connection to the IP-EFOY-GATEWAY over terminal software like Hyper term, Tera term. To use this option, a service (TCP Service Port) has to be started first over the web interface.
IP address and of course all products deployed by Ingenieurbüro Piwek. If an EFOY PRO is in error state, or running out of methanol, the IP-EFOY-GATEWAY on the tactical map lights up red. The operator is now able to react very quickly within few minutes.
Also, on the tactical map, the IP-EFOY-GATEWAY icon will light up and show the error. By doing so, our per- sonnel can see which fuel cell is in error, what the cause is and what equipment is depending on the fuel cell.
SNMP EFOY PRO Fuel Cell Remote Control Due to SNMP V2C network protocol support of the IP-EFOY-GATEWAY, the system is capable of providing a given set of variables called OIDs, reflecting the EFOY PRO fuel cell's state, to the customers network man- agement system.