Emulex LP850 Installation Manual

Fibre channel pci host adapter

Advertisement

Quick Links

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals
Prerequisites:
One open 32-bit or 64-bit PCI bus slot with a 3.3 VDC or 5.0 VDC signaling interface
l
Maximum PCI bus clock rate of 33 MHz
l
Media and connectors (user supplied; view
l
Follow these procedures to assemble and install the host adapter. Click procedures for
details. When finished, click "Return to top of page" to return to this summary.
1.
Record reference
number.
2.
Install the host adapter
computer's motherboard.
3.
Attach
media. Connect fiber optic or copper duplex cabling to the host adapter.
4.
Apply
power. Apply power to the computer and
After the host adapter is installed,
check host adapter functions or update firmware.
Record reference numbers
Each host adapter is shipped with a unique address identifier called the IEEE address. The
Fibre Channel industry uses a World Wide Name (WWN) derived from the IEEE address,
and this number is need for arbitrated loop connectivity. The serial number is used when
communicating with Emulex. Both numbers are clearly marked on the board. We
recommend that you record these numbers before installation.
Install the host adapter board
1. Turn off and unplug the computer.
2. Remove the computer case.
3. Remove the blank panel from an empty 32 or 64-bit PCI bus slot.
4. Insert host adapter board into the empty 32 or 64-bit PCI bus slot. Press firmly until
seated.
5. Secure the host adapter's mounting bracket to the case with the panel screw.
Copyright Emulex Corporation - All rights reserved, 1999
numbers. Write down the host adapter's IEEE address and serial
board. Insert the host adapter board into a PCI slot on the
install device drivers
supported media
types.)
observe the LED
display.
or run a
DOS diagnostic program
Return to top of page.
Page 1 of 10
to

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LP850 and is the answer not in the manual?

Questions and answers

Summary of Contents for Emulex LP850

  • Page 1 Fibre Channel industry uses a World Wide Name (WWN) derived from the IEEE address, and this number is need for arbitrated loop connectivity. The serial number is used when communicating with Emulex. Both numbers are clearly marked on the board. We recommend that you record these numbers before installation.
  • Page 2: Attach Media

    The host adapter is now installed in the PC. Continue with the attach media section. Return to top of page. Attach media Select one of these types of media supported by the Emulex host adapter: (50/125 µm or 62.5/125 µm) Multimode fiber optic cable...
  • Page 3 LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 3 of 10 2. Connect other end of cable to Fibre Channel device. After the media is connected to the host adapter, you are ready to apply power to the computer.
  • Page 4: Apply Power

    LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 4 of 10 2. Connect other end of cable to Fibre Channel device. After the media is connected to the host adapter, you are ready to apply power to the computer.
  • Page 5 (DB9 connector). By connecting an MIA to a copper DB9 connector on a host adapter, a non-Open Fiber Control (non-OFC) optical link is provided. The Emulex host adapter with a copper interface is designed to support an MIA that conforms with the Fibre Channel - Media Interface Adapter specification.
  • Page 6: Supported Media Types

    LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 6 of 10 Note An MIA is user supplied. To attach an MIA, 1. Connect the MIA DB9 connector to the host adapter copper DB9 connector. 2. Tighten screws carefully - do not over tighten.
  • Page 7 LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 7 of 10 failure while functioning failure while functioning slow blink (1 normal - inactive flashing normal - active (irregular) fast blink normal - busy (4 Hz) slow blink normal - link down or not yet started...
  • Page 8 Shielded cables must be used between this equipment and attached peripheral devices. The reader is cautioned that changes or modifications made to the equipment not expressly approved by Emulex could void the user’s authority to operate this equipment.
  • Page 9 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The reader is cautioned that any changes or modifications to the equipment not expressly approved by Emulex could void the user’s authority to operate this equipment.
  • Page 10 LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 10 of 10 Translation: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. VCCI—A...
  • Page 11: Laser Safety Notice

    PCI slot. In the United States, all optical GLMs, GBICs and 1x9 transceivers sold by Emulex are certified as Class 1 laser products that conform to the requirements contained in the Department of Health and Human Services (DHHS) regulation 21 CFR subchapter J.
  • Page 12: Product Information

    (OFC). In the event of a break anywhere in the path, this control system prevents laser emissions from exceeding Class 1 levels. For Copyright Emulex Corporation - All rights reserved, 1999...
  • Page 13: Usage Restrictions

    Any system level product that incorporates the GLM must provide power supply protection that guarantees a voltage of 6.0 volts or less at the GLM. The functional power supply range of the GLM Copyright Emulex Corporation - All rights reserved, 1999...
  • Page 14 Return to top of page. System Level Certification All GLMs and GBICs sold as accessories by Emulex or host adapters containing embedded 1x9 transceivers are certified as Class 1 laser products within the U.S. and Class 1 laser component assemblies outside of the U.S.
  • Page 15 Fibre Channel drives connected to the host adapter using fiber optic or copper duplex media (user supplied) Follow this procedure to install the Emulex SCSI mini port driver for Windows NT 4.0. Click procedure for details. When finished, click "Return to top of page" to return to this summary.
  • Page 16 LightPulse Fibre Channel PCI Host Adapter Drivers Page 2 of 2 11. Select Drivers tab. Verify the Emulex SCSI mini-port driver is present and started. 12. Select Devices tab. Verify that the host adapter is present. 13. Click the "+" sign to expand the adapter listing.
  • Page 17 Windows NT 4.0 SCSI Port Driver Utility Use the Emulex Configuration Utility to configure LP6000, LP7000/E and LP8000 host adapters. Perform LUN mapping, SCSI device mapping, upgrade host adapter firmware, and modify driver parameters in the Windows NT registry.
  • Page 18: Dos Diagnostic Utility

    DOS 6.x or higher (program may not run in the DOS shell under Windows on all systems. Loopback connector for expanded testing (user supplied) Follow these procedures to perform hardware diagnostic testing of an Emulex host adapter. Click procedure for details. When finished, click "Return to top of page" to return to this summary.
  • Page 19 Reports revision levels of diagnostic and functional firmware. Displays the resources of each host adapter. If no host adapter is found, the program will exit. Error messages are displayed when failures occur. Copyright Emulex Corporation - All rights reserved - 1999...
  • Page 20: Modify Test Options

    Internal BIU PCI loopback and other loopback tests are run automatically. 2. Choose 0 (No) if you do not have an external loopback connector. External loopback tests are disabled by default (0 = No (default); 1 = Yes). Modify Test Options Copyright Emulex Corporation - All rights reserved - 1999...
  • Page 21: Maintenance

    Select this option to display this host adapter data: BIU PCI Configuration Parameters Host Adapter Info and Status Adapter Revisions Display Configuration data Service Parameters Status/Counters Info Link Status Link Attention Copyright Emulex Corporation - All rights reserved - 1999...
  • Page 22: Upgrade Firmware

    DOS 6.x or higher (program may not run in the DOS shell under Windows on all systems. DOS diagnostic utility program installed Firmware image file upgrade (available from Emulex ftp server at ftp.emulex.com/pub/fibre. No memory manager programs like Expanded Memory Manager (EMM386) currently running.
  • Page 23 Page 1 Windows NT 4.0 SCSI Port Driver Utility The Emulex Configuration Utility (elxcfg.exe) is installed automatically as an executable during the SCSI port driver installation. A shortcut to the utility is located on the Start Menu under Programs. When launched, the configuration utility will probe the registry. Adapters defined in the registry are listed in the Available Adapters list box.
  • Page 24 Firmware The Firmware button is used to download a new firmware image into the host adapter's flash ROM. Firmware images can be downloaded from the Emulex FTP site. The firmware will be verified, downloaded, and the adapter restarted. Copyright Emulex Corporation - All rights reserved - 1999...
  • Page 25 Disable – Tells the driver to disable auto mapping. You must use the utility to manually map devices. New devices will not be usable until the device is mapped. Copyright Emulex Corporation - All rights reserved - 1999...
  • Page 26 N-Ports. Disable – The driver will ask for all registered SCSI FCP devices. Emulex adapters register as a SCSI FCP device. If Note the only devices on the fibre channel are Emulex Adapters and storage devices, the same list of devices will be returned for each of the two choices.
  • Page 27 LightPulse Fibre Channel PCI Host Adapter Management Page 5 of 7 reporting all present LUNs. If this option is enabled and the target device supports Report LUNs, then the Maximum number of LUNs is ignored for the target device. Disable - If the target does not support the Report LUNs SCSI command or the option is disabled, then the driver will poll each device for the present LUNs.
  • Page 28 LightPulse Fibre Channel PCI Host Adapter Management Page 6 of 7 Enable –SLI-1 is used even if the adapter is capable of SLI-2. Disable – The driver will use SLI-2. Maximum Number of LUNs This is the number of LUNs the driver will poll during device discovery. The minimum value is 1, the maximum value is 255.
  • Page 29 LUN map shows the LUN mapping for a selected target. Note The LUN Map button will only be enabled if the LUN Mapping check box is checked for the adapter. Return to top of page. Copyright Emulex Corporation - All rights reserved - 1999 file://E:\emuweb\WWWROOT\ts\fibre-channel\docs\manage pdf\7pt_util.htm 3/24/99...
  • Page 30 Run the utility from the floppy or copy and run it from your local hard drive. Requires: Windows NT version 4.0 or greater Installed LP6000, LP7000/E, LP8000, or LP850 host adapter Installed Windows NT SCSI Mini Port Driver The LightPulse Utility/NT Requires that the...
  • Page 31: Firmware Maintenance

    LightPulse Fibre Channel PCI Host Adapter Management Page 2 of 6 There are eight options available, each displaying a different group of host adapter parameters: Adapter Revision Levels - View information about the chipset and firmware revision levels of the selected adapter. Firmware Maintenance - View detailed information about the firmware in the Flash ROM of the selected host adapter.
  • Page 32 Enable or disable the adapter's Boot BIOS Upgrade Host Adapter Firmware 1. Obtain a copy of the desired upgrade file. Upgrade files are available on the Emulex ftp server at ftp.emulex.com/pub/fibre/. 2. Start the utility. 3. Select the desired host adapter 4.
  • Page 33 LightPulse Fibre Channel PCI Host Adapter Management Page 4 of 6 Return to top of page. Enable or Disable Boot BIOS Boot BIOS is used to designate a Fibre Channel drive as the boot drive. To enable a Fibre Channel drive as the boot drive, first enable Boot BIOS using this procedure and then refer to the Boot BIOS section.
  • Page 34 Update Device Driver Device drivers are updated periodically and can be obtained from the Emulex website at ftp.emulex.com/pub/fibre/. In the Windows NT environment, you should remove the existing driver before installing a new driver. Follow the steps below to remove an existing...
  • Page 35 2. Double click the SCSI Adapters icon. 3. Select Drivers tab. 4. Click Remove, and Yes to confirm. 5. Click OK. 6. Reboot the computer to restart Windows NT. Install new driver. Copyright Emulex Corporation - All rights reserved - 1999 file://E:\emuweb\WWWROOT\ts\fibre-channel\docs\manage pdf\5nts_1ut.htm 3/24/99...
  • Page 36 LightPulse Fibre Channel PCI Host Adapter Management Page 1 of 4 Boot BIOS Utility Requirements: Intel Pentium computer system, with system BIOS copyrighted 1995 or later MS-DOS 6.0 or higher Installed LP3000, LP6000, LP7000/E or LP8000 host adapter Connected Fibre Channel drive or disk array Boot BIOS does the following: Supports up to 8 LightPulse Fibre Channel host adapters per computer.
  • Page 37 LightPulse Fibre Channel PCI Host Adapter Management Page 2 of 4 device on the first adapter will be the boot disk. To specify a Fibre Channel drive as the boot device, enter a two digit number (01, 02, etc.) to specify which drive will be the boot device. (After specifying a device as the boot device, go to menu option 6 to verify that device is enabled).
  • Page 38 LightPulse Fibre Channel PCI Host Adapter Management Page 3 of 4 Enable or Disable Individual Devices (+ Advanced Option +) This option applies only to arbitrated loop (FC-AL). Default is enabled for each device. Each device can be enabled or disabled by the user. The maximum number of devices (including LUNs) that can be displayed in the device menu is 99 per adapter.
  • Page 39 WWPN only. Name Server Inquiry is issued to locate the D_ID of this WWPN. If found, a boot can occur. D_ID only. PLOGI is issued to this D_ID regardless WWPN. Copyright Emulex Corporation - All rights reserved - 1999 file://E:\emuweb\WWWROOT\ts\fibre-channel\docs\manage pdf\6bbios2.htm 3/24/99...
  • Page 40: All Operating Systems

    LightPulse Fibre Channel PCI Host Adapter How to... Page 1 of 11 All Operating Systems Boot from a fibre channel drive Boot BIOS works with the existing system BIOS on Intel Pentium PCI motherboards and allows a system to boot from a fibre channel drive. Connect a fiber optic cable to a copper port Use an MIA to convert media.
  • Page 41 Ethernet packets (802.3 SNAP) by changing registry values. Perform LUN mapping This procedure requires the use of the Emulex Configuration Utility. This Utility is installed along with the Windows NT 4.0 SCSI Port driver. Perform manual SCSI mapping This procedure requires the use of the Emulex Configuration Utility.
  • Page 42 Page 3 of 11 Installed host adapter Connected Fibre Channel drive or disk array The Emulex SCSI mini-port driver LP6dutil DOS Diagnostic, version 8.3 or higher Defining a Fibre Channel Drive as the Boot Drive The following is a summary of the procedures necessary to define a Fibre Channel disk drive as the boot drive in Windows NT 4.x.
  • Page 43 LightPulse Fibre Channel PCI Host Adapter How to... Page 4 of 11 1. Type <5> and press <Enter> to open the Maintenance menu. 2. Type <3> and press <Enter> to enable Boot BIOS. 3. Type <0> and press <Enter> to return to the previous menu. 4.
  • Page 44 This procedure allows a user to select a Fibre Channel boot drive. 1. Insert the newly created boot disk in drive A. 2. Turn on the computer. 3. Press <F5> immediately when the message displays to go to the Emulex BIOS Utility. Note Press <F5> within 5 seconds of the displayed message to invoke the Boot BIOS utility.
  • Page 45 LightPulse Fibre Channel PCI Host Adapter How to... Page 6 of 11 Adapter ALPA: 18 PCI BUS #: 00 PCI DEVICE #: Change BIOS Boot Device/Display All Devices. Change default ALPA of this Adapter. Enable or Disable BIOS on this Adapter. Change FC Link Timer (+ Advanced Option +) Changed Extended Link Service Timer (+ Advanced Option +) Enable or Disable Individual Devices (+ Advanced Option +)
  • Page 46 4. Select Other and press <Enter>. 5. Insert the Emulex Windows NT SCSI driver diskette. 6. Select the Emulex Fibre Channel SCSI driver and press <Enter>. 7. Insert the Windows NT CD-ROM when prompted. 8. Insert the Emulex driver diskette again when prompted.
  • Page 47 Follow these procedures to upgrade or reinstall the device driver. Click procedure for details. When finished, click "Return to top of page" to return to this summary. Obtain driver - Obtain new driver from the Emulex ftp site at ftp.emulex.com/pub/fibre. 2. Remove driver - Procedure differs for Windows NT 4.0, AIX, Solaris, or UnixWare.
  • Page 48 LightPulse Fibre Channel PCI Host Adapter How to... Page 9 of 11 Windows NT 4.0 IP driver From the Windows NT desktop, 1. Click Start button, select Settings, and click Control Panel. 2. Double click the SCSI Adapters icon. 3. Select Drivers tab. 4.
  • Page 49 LightPulse Fibre Channel PCI Host Adapter How to... Page 10 of 11 5. Reboot the system. Return to top of page. Versions 2.0.0.0 or Above 1. Login as root. 2. Open terminal window and type this command to uninstall old network drivers (fchan).
  • Page 50: Upgrade Firmware

    DOS 6.x or higher (program may not run in the DOS shell under Windows on all systems. DOS diagnostic utility - Download version 8.4 Firmware image file - Download latest versions from the Emulex ftp server at ftp.emulex.com/pub/fibre No memory manager programs like Expanded Memory Manager (EMM386) currently running.
  • Page 51 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 1 of 14 AL_PA Table When a device is connected to a Fibre Channel arbitrated loop, the loop initialization process (LIP) automatically assigns an ALPA (Arbitrated Loop Physical Address) to the device.
  • Page 52 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 2 of 14 Windows NT Event Viewer The Windows NT SCSI driver verifies the success of the PCI Host adapter’s Power On Self Test (POST). In case of a failure or suspected failure, an error log entry is issued to the Windows NT System Event Logger (Viewer).
  • Page 53 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 3 of 14 Mailbox Interrupt Time- 0xD7 0x11= Mailbox word 0 TPRLO requested when 0x11= local req. state, 12= discState, 13= Mailbox 0xD8 busy word 0 Link down time-out 0x11= local req. state, 12= discState, 13= Mailbox 0xD9 occurred word 0...
  • Page 54 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 4 of 14 LinkUp w/ Illegal or 0xF2 0x11= parameter field, 12=IOCB cmd corrupt RPI DeQueue ring- 0xF3 0x11= caller ID >iotCmd.head 0xF4 Adapter Reset 0x11= coded reason for reset: bit 0=IOCB Requeue;...
  • Page 55 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 5 of 14 IOSTAT_FCP_RSP_ERR IOSTAT_REMOTE_STOP Remote sent an ABTS IOSTAT_LOCAL_REJECT Parameter field contains additional info IOSTAT_NPORT_RJT IOSTAT_FABRIC_RJT IOSTAT_NPORT_BSY IOSTAT_FABRIC_BSY IOSTAT_INTERMED_RSP IOSTAT_LS_RJT IOSTAT_BA_RJT d0xA Return to top of page. Parm error values (valid only when cmdStat=0x3) IOERR_SUCCESS 0x00 IOERR_MISSING_CONTINUE...
  • Page 56 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 6 of 14 IOERR_RCV_BUFFER_WAITING 0x0B IOERR_NO_CONNECTION 0x0C IOERR_TX_DMA_FAILED 0x0D IOERR_RX_DMA_FAILED 0x0E IOERR_ILLEGAL_FRAME 0x0F IOERR_EXTRA_DATA 0x10 IOERR_NO_RESOURCES 0x11 IOERR_RESERVED 0x12 IOERR_ILLEGAL_LENGTH 0x13 IOERR_UNSUPPORTED_FEATURE 0x14 IOERR_ABORT_IN_PROGRESS 0x15 IOERR_ABORT_REQUESTED 0x16 IOERR_RECEIVE_BUFFER_TIMEOUT 0x17 IOERR_LOOP_OPEN_FAILURE 0x18 IOERR_RING_RESET 0x19...
  • Page 57 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 7 of 14 1. Install the first host adapter. 2. Leave one host adapter's jumpers in the default position: JX1:1-2 and JX2:2-3. 3. On the second host adapter, move jumper JX1:1-2 to JX1:2-3 to enable jumper block JX2.
  • Page 58 LAN registry parameter window and make changes there. A second method is to run the registry configurator program (lp6conf.exe) which came with the Emulex Windows NT driver. After running configurator program, the system must be rebooted. You can also add or modify the class entry in the Windows NT registry as shown below.
  • Page 59 Return to top of page. 802.3 SNAP The Emulex Windows NT IP driver uses the 802.3 SNAP frame encoding format. By default, Microsoft Windows NT TCP/IP stack transmits DIX Ethernet format only, but is able to receive both DIX and 802.3 SNAP formats. Changing this registry value to 1 forces Windows NT TCP/IP to transmit Ethernet packets using 802.3 SNAP encoding.
  • Page 60 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 10 of 14 HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters ArpUseEtherSnap REG_DWORD default is 0; set to 1 to enable 802.3 SNAP Modify the Windows NT Registry Before changing any values, we recommend Note making a backup copy of the registry. Changes made incorrectly to the Windows NT Registry will have disastrous effects.
  • Page 61 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 11 of 14 EnableDPC = n level, 1 = process at DPC level. Values from 1 - 8. Default = 8. Controls the upper byte of receive FrameSize if issued in PLOGI. This allows the FrameSize to be FrameSizeMSB = n constrained on 256 byte increments from 256 (1) - 2048 (8).
  • Page 62 LightPulse Fibre Channel PCI Host Adapter How to Guide Page 12 of 14 Values are in milliseconds from 100 to 511. Default = 256. RTTOV = n Represents time-out between phases of Offline to Online protocol. Values 0 or 1. Default = 0. 0 = Lowest AL_PA = Lowest physical ScanDown = n disk (ascending AL_PA order).
  • Page 63 8. Enter the NT LUN number. This number is self-incrementing. Manual SCSI Mapping From the Windows NT desktop, 1. Click Start menu, select Programs group, and select Emulex Configuration Utility. The Configuration Utility main window opens: Note In the Adapter Controls section, uncheck (if checked) the Automatically Map SCSI devices box.
  • Page 64 Upgrade Firmware From the Windows NT desktop, 1. Obtain a copy of the desired upgrade file. 2. Upgrade files are available on the Emulex ftp server at ftp.emulex.com/pub/fibre/. 3. Click Start menu. 4. Click Programs group. 5. Click the Configuration Utility.
  • Page 65: Declaration Of Conformity

    DECLARATION OF CONFORMITY Emulex Corporation Manufacturer: 3535 Harbor Blvd. Costa Mesa, CA 92626 declares under sole responsibility that the product: LightPulse ™ LP850 Fibre Channel PCI Host Product Name: Adapter Assembly Number: FC1020017-XX (GBIC model) FC1020016-XX (Embedded Optical, 1x9 model)
  • Page 66 3535 Harbor Blvd. Costa Mesa, CA 92626 declares under sole responsibility that the product: Product Name: LightPulse™ LP850 Fibre Channel PCI Host Adapter Assembly Number: FC1020019-XX (Embedded DB9 model) to which this Declaration relates is in conformity with the following standards or...

Table of Contents