Variable controlled output (vco)
solar compatible gas condensing boilers (10 pages)
Summary of Contents for Eco Hometec EC 25 COMPACT
Page 1
Variable Controlled Output (VCO) Solar Compatible jjjjj Gas Condensing Boilers EC 25 COMPACT...
Page 2
C:\amanuals\EC25CompactTechnicalManual021099.doc\30 June 2002 eco hometec has a policy of continuous improvement and reserves the right to change any specification without notice. Your statutory rights are not affected. eco hometec is committed to design, develop and produce environmentally friendly appliances...
Why choose eco hometec? Benefits at a glance Wall mounted ultra high efficiency gas boilers Suitable for installation into existing systems, new radiator and/or underfloor installations, can also be used with solar heating systems A dramatic reduction of the harmful emissions NOx 8.1 – 27.1 ppm and CO 2.9 –...
The water return consequences of burning and wasting so temperature determines whether the boiler much fuel were not fully appreciated. operates in condensing mode, which in turn controls the boilers efficiency. EC 25 Compact Technical Manual page...
Variable Controlled output (VCO) Answer: Unlike conventional boilers eco hometec appliances do not need To achieve optimum efficiency from a to waste gas in maintaining high flue gas condensing boiler we need to control the temperatures. temperature of the water returning to the boiler.
3 way switching valve and facilities for cut out thermostat installing as part of the connection to an eco hometec DHW storage system controls. module or similar. Flow temperature to hot water cylinder can be set as required (max.
Page 9
Figure 1 Solar heating EC25 ‘S’ Type Combi Hydraulic system design when installed with solar heating EC 25 Compact Technical Manual page...
European calculation methods are based on efficiency of 100% in units that do not condense the flue gases, and of 110% in condensing units. & & EC25 Model litres Heating Water Capacity Litres Heating Water Coil Capacity (S models) Weight (empty) Page 10 ECO HOMETEC...
Page 11
2.9 – 66 ppm CO (0 % O natural gas: 8.1 – 27.1 ppm NOx (0 % O 50 dB(A) Noise Levels Pump high speed 34 dB(A) Noise Levels Pump low speed EC 25 Compact Technical Manual page...
Page 13
Hot water sensor Exhaust gas sensor Type plate Condensation drain/high pressure protection Central Heating Return Central Heating Flow Hot water outlet Cold water inlet Flow to Hot Water Cylinder Return from Hot Water Cylinder EC 25 Compact Technical Manual page...
Accessories The following items are also available from eco hometec at extra cost. Colour coded 1/4 Turn Isolating Valves. Stainless Steel Flexible Pipe Connections. In line Filter/Strainers. Condensate sump pump for below ground installations. N.B. LPG installations must not be installed below ground level.
Figure 3 shows the order in which to fix the pipe-work. Connections 1. Gas 2. Heating Return 3. Heating Flow 4. Flow Domestic Hot Water 5. Cold Mains Water 6. Flow to Hot Water Cylinder 7. Return from Hot Water Cylinder EC 25 Compact Technical Manual page...
Modular installations Figure 5 Vertical Wall Terminal For multiple boiler (modular) installations eco hometec supply a range of larger diameter flues. Sizes are available in 150mm, 200mm and 250mm. For assistance in flue design and specification please call the eco hometec technical department.
Page 19
Additional 80/125mm concentric flues tubes and fittings are available from eco hometec details below: 80/125 1000mm length...
Additional 80 PPS flues tubes and fittings Condensate Drain are available from eco hometec details below: The condense discharge pipe should Figure 10 80mm Flue Tubes be continued in ¾ inch plastic waste pipe into the household drainage system or out through the wall to an existing gully or soak away.
For an extended diagnosis and display of functions, a PC or laptop computer can be connected to connector (3) (Fig. 13). The required connecting cable and software is available from eco hometec as an option. 8.1.5 Frost protection 11.2 If the temperature detected by the supply sensor falls below 8 °C, the pump will be...
40 < ∆T < 45 low load is restarted at high speed. The fan runs and > 45 the pre-ignition phase begins. At the end of the pre-ignition phase the system pressure is measured again. The following situations are possible: Page 22 ECO HOMETEC...
3.0 bar. The pressure can be display. read from the display. Once in every two hours the difference between supply and return temperatures must have been less than 5 °C. Is this not EC 25 Compact Technical Manual page...
System drop with mixing valves, the temperature from a fixed 80 C start point. Under-floor The eco hometec range of VCO boilers has 14.4 been specifically designed to work with low Flow temperature temperature under-floor heating. Return temperature...
As heating our homes accounts for 70% of diameters for the heating circuits. our annual fuel bills. This will result in lower heat losses, due to smaller diameter pipework, and should WHY? result in installation savings with reduced EC 25 Compact Technical Manual page...
Page 26
Save gas Save money Only boilers from eco hometec are fitted with Variable Controlled Output eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster DN6 8DD Tel. 01302 722266 Fax. 01302 728634 http://www.eco-hometec.co.uk e.mail.sales@ecohometec.co.uk Page 26 ECO HOMETEC...