Electrical Adjustments
●
Service Adjustment Data Table
CAUTION :
These initial values are the reference data written from the CPU ROM to the memory IC when the new
memory IC replaced. The adjustment items indicated with "✽" are required to readjust following to the
"Electrical adjustments". Other items should be used with the initial data value.
Group
Item
No.
No.
S
0
–
Temperature Monitor Indication
–
0
LM76 (Temp) Monitor
–
1
LM76 (Temp) Monitor
–
2
Thermistor Monitor
–
3
Thermistor Monitor
S
1
–
Pressure Monitor Indication
–
0
MPXA4114A(Pressure) Monitor
S
10
–
RS232C Set
–
0
Baud rate
–
1
RTS/CTS Flow Control
–
2
CTS Timeout Second
–
3
Serial Address
S
20
–
Logo On/Off
–
0
Logo On/Off
S
30
–
Color Shading Correction
–
0
Correction On/Off
S
40
–
Dimmer Control
–
0
Dimmer On/Off
–
1
Dimmer Level
S
80
–
Projector Time
–
0
Projector Time
S 113
–
Reset Frequency Counter
–
0
Lamp 1
–
1
Lamp 2
–
2
Lamp 3
–
3
Lamp 4
S 115
–
Lamp Go Out
–
0
Lamp Go Out
S 120
–
RC KEY Disable
–
0
RC Zoom & Focus Only
–
1
RC / KEY All
–
2
Process after Power Fail
S 121
–
RC Select
–
0
RC Direct Select
S 140
–
Fan Output Level
–
0
Fan A Min
–
1
Fan A Max
–
2
Fan C Min
–
3
Fan C Max
–
4
Fan B Min
–
5
Fan B Max
–
6
Fan D1 Min
–
7
Fan D1 Max
–
8
Fan D2 Min
–
9
Fan D2 Max
–
10
Fan D3 Min
–
11
Fan D3 Max
–
12
Fan D4 Min
–
13
Fan D4 Max
S 141
–
Fan Output Level
–
0
Fan Output Level
S 150
–
Factory Set (Reset)
–
0
Factory Set Do not touched.
S 160
–
Shootout
–
0
Switch
S 180
–
DDC Setting
–
0
HDCP EDID Data Setting
S 200
–
CG Full Lamp
–
0
G-SIG Center
–
1
R-SIG Center
–
2
B-SIG Center
–
3
SDIA G
–
4
SDIB G
–
5
SDIA R
Item
Temp. Sensor (Intake)
Temp. Sensor (Inner)
Temp. Thermistor (Inner)
DAC value
Pressure Sensor
RS232C Baud rate (0 : 9600 / 1 : 19200)
RS232C RTS/CTS Flow Control (0 : Disable / 1: Enable)
RS232C CTS Timeout
Individual address in RS–232C chain connection
(0 : Menu Operation / 1 : Prohibition)
(0 : Off / 1 : On)
(0 : Menu Operation / 1 : Off)
(0 : 200W ~ 15 : 250W)
Lamp 1 Total Lighting Time
Lamp 2 Total Lighting Time
Lamp 3 Total Lighting Time
Lamp 4 Total Lighting Time
0 : Disable / 1 : Enable
0 : Enable / 1 : Disable
0 : Enable / 1 : RC Disable / 2 : KEY Disable
0 : Not Recover by KEY / 1 : Recover by KEY
0 : Rear & Front / 1 : Front / 2 : Rear / 3 : Disable
✽
(
) Fan A Driving Voltage Adj. at TP7611
✽
(
) Fan A Driving Voltage Adj. at TP7611
✽
(
) Fan C Driving Voltage Adj. at TP2661
✽
(
) Fan C Driving Voltage Adj. at TP2661
✽
(
) Fan B Driving Voltage Adj. at TP2671
✽
(
) Fan B Driving Voltage Adj. at TP2671
✽
(
) Fan D1 Driving Voltage Adj. at TPFN1
✽
(
) Fan D1 Driving Voltage Adj. at TPFN1
✽
(
) Fan D2 Driving Voltage Adj. at TPFN2
✽
(
) Fan D2 Driving Voltage Adj. at TPFN2
✽
(
) Fan D3 Driving Voltage Adj. at TPFN3
✽
(
) Fan D3 Driving Voltage Adj. at TPFN3
✽
(
) Fan D4 Driving Voltage Adj. at TPFN4
✽
(
) Fan D4 Driving Voltage Adj. at TPFN4
0 : Max / 1 : Factory / 2 : Auto / 3 : Min
Available at No.10 caution : Important! Do not attempt.
0 : Enable / 1 : Disable
0 : EDID Data for DVI / 1 : EDID Data for HDCP
( Factory Use – PC Mode )
✽
(
) DAC Video Center G
✽
(
) DAC Video Center R
✽
(
) DAC Video Center B
DAC PSIGA
DAC PSIGB
DAC PSIGA
Function
–86–
Initial Value
Data
Range
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
0 / 1
1
–
0 / 1
0
–
0 ~ 255
0
–
0 ~ 999
1
–
0 / 1
0
–
0 / 1
1
–
0 / 1
1
–
0 ~ 15
15
–
0
–
0 ~ 127
0
–
0 ~ 127
0
–
0 ~ 127
0
–
0 ~ 127
0
–
0 / 1
0
–
0 / 1
0
–
0 ~ 2
0
–
0 / 1
0
–
0 ~ 3
0
0 ~ 255
210
–
0 ~ 255
10
–
0 ~ 255
210
–
0 ~ 255
20
–
0 ~ 255
200
–
0 ~ 255
25
–
0 ~ 255
110
–
0 ~ 255
30
–
0 ~ 255
130
–
0 ~ 255
40
–
0 ~ 255
110
–
0 ~ 255
30
–
0 ~ 255
130
–
0 ~ 255
40
–
0 ~ 3
2
–
0 ~ 10
0
–
0 / 1
0
–
0 / 1
1
–
0 ~ 255
32
–
0 ~ 255
32
–
0 ~ 255
32
–
0 ~ 255
15
–
0 ~ 127
214
–
0 ~ 127
15
–