STOP NUISANCE ALARMS

Push the test/silencer button on the initiating (primary) smoke alarm after
OWNERS MANUAL FOR
the alarm has started, and the sound will stop immediately. The test LED
will continue to flash as long as the smoke level is higher than the reduced
WIRELESS INTERCONNECTABLE
smoke sensitivity (silencer/hush) level. All other units will continue to
PHOTOELECTRIC SMOKE ALARM.
Alarm for another 5-15 seconds, however with another sound character,
See also the "ALARM" section.
MODEL PR1211

TEST

Each smoke alarm can be tested individually by a short push of the
test/silencer button. Then the siren in the smoke alarm will sound, all
features (except radio transmission) are checked. At the same time the
smoke alarm's sensitivity is reduced (see the "SILENCER/HUSH" feature
section) and two short beeps will be heard.
If you would like to test the wireless alarm feature the test/silencer button
should be pushed for more than 3 seconds. (The smoke alarm will not go
into silencer mode) After this the test/alarm LED will shine constantly for
40 seconds, and this confirms that radio transmission is taking place.
After a short delay all other units will start to alarm (but with a different
alarm sound) the alarms will stop after 25-40 seconds. If other units are to
be tested, there should be a delay of at least 40 seconds between each
testing.

MEMORY FUNCTION

When a unit alarms due to smoke or other reasons (not from test button),
the memory function will be activated in the unit that has detected the
smoke and will be held up for 12 hours. The indication of an alarm
incidence being stored in the memory function consists of a short beep
about every 8 seconds, followed by LED flashes. During this memory
indication period, the normal operating and function of the unit is not
affected and the user can reset/deactivate the memory function by pressing
the test push button until an alarm sounds.
IMPORTANT INFORMATION ABOUT RADIO
TRANSMISSION OF ALARMS
Regularly check the range and function, so that the smoke alarm could be
heard sufficiently in the bedrooms, both before and after installation.
Please note that radio conditions and interference etc. can change over
EN14604 : 2005
time, therefore no guarantee can be given about a specific transmission
range etc. Each time, place and building are unique from a radio
transmission point of view.
©
COPYRIGHT
40-722

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PR1211 and is the answer not in the manual?

Questions and answers

Summary of Contents for Homewatch PR1211

  • Page 1 PHOTOELECTRIC SMOKE ALARM. alarm for another 5-15 seconds, however with another sound character, See also the “ALARM” section. MODEL PR1211 TEST Each smoke alarm can be tested individually by a short push of the test/silencer button. Then the siren in the smoke alarm will sound, all features (except radio transmission) are checked.
  • Page 2: Battery Installation

    These smoke alarms are equipped with a very sophisticated, and reliable ALARM radio system. Due to the use of modern and advanced components, the There are two (three) different alarm sounds to differentiate where and range and penetration is high, while the current consumption is extremely which unit is the source of the alarm.

Table of Contents