  • Page 1: Operating Instructions

    RadStar RS300 Operating Instructions R S300 F E A TUR ES • Accurate measurement in a wide range • 12 or 24-hour start time delay option of temperatures and relative humidity • Internal memory to retain data • Nominal sensitivity: 16 cph/pCi/L...
  • Page 2 Table of Contents 1.0 SE TTIN G UP TH E R S3 0 0 2.0 TU RN IN G UN IT O N 3 .0 ERA SIN G STO R E D DA TA 4 .0 MO NIT O R ING F O R R A D O N G AS 5.
  • Page 3 1.1 Plug power adapter that is marked “RadStar Power Supply” into any 120VAC outlet. 1.2 Plug free end of power adapter into left side of RS300-Green LED should come on. This tells you that the NiCad batteries are charging. Power cord should be left plugged in at all times during a radon test to ensure that the batteries remain charged.
  • Page 4 5.0 O BTAIN IN G A REA D I NG F R OM THE R S30 0 : 5.1 Any time during or after a test turn the keyswitch to [Keypad On] position. Note: To continue testing at anytime when the keyswitch has been turned to the [ Keypad On ] or the [ Off ] position, simply turn the keyswitch to [ Measure On ] position.
  • Page 5 8.0 DO W NL O AD ING DATA F R OM T HE R ADS TAR: The RadStar comes with a Data Capture Utility Program (Windows XP and Vista compatible), and a USB/Serial Adapter Cable with driver. The accompanying RadStar Documentation Library describes the set-up and operation of these items.
  • Page 6 F I G U R E A E XA M P L E R S 30 0 T E S T R E S U L T P R I NTO U T...
  • Page 7 Manufactured by RadonAway 3 Saber Way Ward Hill, MA 01835...
  • Page 8 RS300 Instrument Specifications Mode: Continuous Monitor, Passive Diffusion Principle of Operation: Pulse Mode Ionization Chamber Minimum Sensitivity: 0.27 cpm/pCi/L (minimum 64 alpha counts per hour @ 4 pCi/L) Units: picoCuries per liter (pCi/L) Dynamic Range: 0.5 to 150 pCi/L Linearity:...