Metrologic MX009 Manual

Metrologic MX009 Manual

Usb converter
Hide thumbs Also See for MX009:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Metrologic MX009

  • Page 2 Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
  • Page 3: Table Of Contents

    What is the difference between USB Keyboard Emulation and USB Serial Emulation? ..................1 How is the MX009 Configured for USB Keyboard Emulation?......2 How is the MX009 Configured for USB Serial Emulation? ........3 MX009 USB Cable Options ...................4 Part Number Designation and Accessories ............5 Cable Installation ....................6...
  • Page 5: How Does The Mx009 Usb Cable Operate

    PC application as if the keys were pressed on the PC’s keyboard. When the MX009 is set-up to communicate as a USB Serial device, the data emulates serial (RS232) data through the use of a Metrologic developed driver.
  • Page 6: How Is The Mx009 Configured For Usb Keyboard Emulation

    Data Transmitted = 012345<CR> Prefixes #1 and #2 specify the German keyboard and the <CR> <LF> terminators are needed by the MX009 for framing the data. Only 2 custom prefixes are available on the MS951*, MS6720, MS700, MS860, Tech Series, IS4120* and IS4220*.
  • Page 7: How Is The Mx009 Configured For Usb Serial Emulation

    CONFIGURED FOR ERIAL MULATION This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009. The scanner communicates using RS232 protocol. The default (RS232) settings of the scanner are as follows: • For Non-PowerLink Scanners 9600 baud, 7 data bits, 2 stop bits and space parity •...
  • Page 8: Mx009 Usb Cable Options

    MX009 USB C ABLE PTIONS OMPATIBLE CANNER ODELS UMBER ONNECTOR Discontinued scanner models CANNER TRAIGHT are shown in grey. OILED 10-pin All versions of the: MX009-2MA7 Type A RJ45 MS6220, MS6520, IS6520, MS7100, MS7220, Male MS9500, MS3580 and IS3580 10-pin...
  • Page 9: Part Number Designation And Accessories

    AC to DC Power Transformer (Optional) Dependent † 00-02574 MX009 USB Converter Cable Configuration Guide † Available for download on Metrologic's website, www.metrologic.com. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-METRO or 1-800-436-3876.
  • Page 10: Cable Installation

    ABLE NSTALLATION Make sure the AC input requirements of the power supply match the AC outlet. The outlet should be near the equipment and easily accessible.
  • Page 11: Labels

    Each MX009 has CE, UL and caution information embedded in the back of the case. The following is an example of embedded information. Figure 1. Each MX009 will also have a flag tag attached to the cable with the date of manufacture, model number, and serial number. Figure 2.
  • Page 12: Powerlink Compatible Scanners

    (MX009-2 ONFIGURING FOR EYBOARD MULATION PowerLink Compatible Scanners These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. ® ® • • MS9500 Voyager...
  • Page 13 USB K (MX009-2 ONFIGURING FOR EYBOARD MULATION Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required (defaults to USA). ³ 4 1 6 2 6 0 WITZERLAND ³ 4 1 6 2 8 0 PAIN ³...
  • Page 14 USB K (MX009-2 ONFIGURING FOR EYBOARD MULATION NITED INGDOM ³ 4 1 6 2 1 0 ELGIUM ³ 4 1 6 2 0 0 APANESE ³ 4 1 6 2 1 0 0 IBM 4700 F INANCIAL EYBOARD ³ 4 1 6 2 7 0...
  • Page 15: Ms6720, Ms860, And Tech Series

    (MX009-2 ONFIGURING FOR EYBOARD MULATION MS6720, MS860, ERIES These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • • • MS6720 MS860 Tech Series...
  • Page 16 USB K (MX009-2 ONFIGURING FOR EYBOARD MULATION XON/OFF NABLE ANDSHAKING 1 2 3 4 5 1 1 7 1 4 ACK/NAK NABLE 1 2 3 4 5 1 1 7 1 3 ONFIGURABLE REFIX 1 2 3 4 5 9 2 0 0 0...
  • Page 17 USB K (MX009-2 ONFIGURING FOR EYBOARD MULATION Scan one of the following bar codes to set Keyboard Emulation. ELGIUM 1 2 3 4 5 0 0 0 6 5 NITED INGDOM 1 2 3 4 5 0 0 0 6 6...
  • Page 18 USB K (MX009-2 ONFIGURING FOR EYBOARD MULATION PANISH 1 2 3 4 5 0 0 0 7 0 NITED TATES 1 2 3 4 5 0 0 0 7 1 WISS 1 2 3 4 5 0 0 0 7 3...
  • Page 19: Configuring For Usb Keyboard Emulation (Mx009-2Xx7X)

    USB K (MX009-2 ONFIGURING FOR EYBOARD MULATION ESERVED 1 2 3 4 5 0 0 0 7 6 NTER ONFIGURATION 1 2 3 4 5 6 6 6 6 6...
  • Page 20: Powerlink Compatible Scanners

    USB S (MX009-2 ONFIGURING FOR ERIAL MULATION PowerLink Compatible Scanners These Metrologic scanners must be reconfigured using the following bar codes before the MX009 can communicate properly with the host system. • • MS9500 Voyager Series MS6220 Pulsar • •...
  • Page 21: Ms6720, Ms860, And Tech Series

    USB S (MX009-2 ONFIGURING FOR ERIAL MULATION MS6720, MS860, AND TECH SERIES These Metrologic scanners must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • • • MS6720 MS860 Tech Series...
  • Page 22 USB S (MX009-2 ONFIGURING FOR ERIAL MULATION XON/XOFF NABLE ANDSHAKING 1 2 3 4 5 1 1 7 1 4 ACK/NAK NABLE 1 2 3 4 5 1 1 7 1 3 NTER ONFIGURATION 1 2 3 4 5 6 6 6 6 6...
  • Page 23: Troubleshooting Guide

    ROUBLESHOOTING UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 22. Test Bar Code Scanning the following bar code will transmit the encoded characters followed by the software number of the MX009.
  • Page 24: Specifications

    PECIFICATIONS MX009 USB C ONVERTER ABLE PECIFICATIONS ECHANICAL Dimensions: 80.4 mm (3.2”) L x 32.4 mm (1.3”) W x 18.7 mm (0.7”) H Weight: 160 g (0.35 lb) 10-pin modular RJ45 Male to USB Termination: 10-pin modular RJ45 Female to USB.
  • Page 25: Cable Information

    ABLE NFORMATION Scanner Connector End USB Connector End Locking Type A Type A 10-Pin RJ45 Male MX009-2MA7x MX009-2MB7x Function MX009-2MA8x MX009-2MB8x Ground x = C (coiled) or S (Straight) cable Function Vbus DTR/LP Reserved LP Data Ground +5 VDC From Transformer...
  • Page 26: Limited Warranty

    The MX009 USB converter cables are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility and at its Suzhou, China facility. The MX009 USB converter cables have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MX009 USB converter cables are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
  • Page 27: Notices

    OTICES TESTED TO COMPLY WITH FCC STANDARDS FOR HOME OR OFFICE USE Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 28: Patent Information

    (2) this device must accept any interference received, including interference that may cause undesired operation. Trade Name: METROLOGIC Type of Product: Bar Code Scanner Model: MX009 alphanumeric suffix may follow. ATENT NFORMATION Worldwide patents pending.
  • Page 29: Additional Bar Codes

    DDITIONAL ODES Some Metrologic scanners require alternate configuration steps than the steps found on pages 8 - 18. If your scanner was manufactured before May 2002 or does not accept the standard configuration sequences, you may need to use one of the alternate configuration methods listed on the following pages.
  • Page 30 DDITIONAL ODES *Enable LF Suffix ³ 1 1 6 6 1 2 8. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required. ELGIUM ³ 8 0 3 6 0 6 5 0 NITED INGDOM ³...
  • Page 31 DDITIONAL ODES NITED TATES ³ 8 0 3 6 0 7 1 0 ESERVED ³ 8 0 3 6 0 7 2 0 WISS ³ 8 0 3 6 0 7 3 0 WEDISH INNISH ³ 8 0 3 6 0 7 4 0 APANESE ³...
  • Page 32 DDITIONAL ODES Alternate Configuration for USB Serial Emulation (MX009-2xx8x) PowerLink Compatible Scanners NTER ONFIGURATION ³ 9 9 9 9 9 9 ECALL EFAULTS ³ 9 9 9 9 9 8 RS-232 ENABLE MODE ³ 4 1 5 5 5 4...
  • Page 33 DDITIONAL ODES LF S NABLE UFFIX ³ 1 1 6 6 1 2 NTER ONFIGURATION ³ 9 9 9 9 9 9...
  • Page 34: Contact Information And Office Locations

    Tel: +34 913 272 400 Fax: +34 913 273 829 Email: info@es.metrologic.com Metro (Suzhou) Sales Office Tel: 86-512-67622550 Fax: 86-512-67622560 Metrologic European Repair Center (MERC) Email: info@cn.metrologic.com Metrologic Eria Ibérica, SL Tel: +34 913 751 249 Fax: +34 913 270 437...
  • Page 36 June 2005 Printed in the USA 0 0 - 0 2 5 7 4 D...

Table of Contents