Datalogic QLM700 Installation Manual
Datalogic QLM700 Installation Manual

Datalogic QLM700 Installation Manual

Profinet io gateway

Advertisement

Quick Links

INSTALLATION MANUAL
10
1
Power In Connector and LED
2
ID-NET Connector and LED
3
Trigger Connector and LED
4
I/O Connector and LED
5
Profinet IO Port 1 Connector and LED
QLM700
9
2
1
821002140
8
4
3
Figure A
6
Profinet IO Port 2 Connector and LED
7
Auxiliary Port Connector
8
IP Address Selectors (last octet)
9
Reading Device Connector
10
Mounting slots (6)
7
6
5

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic QLM700

  • Page 1 QLM700 INSTALLATION MANUAL Figure A Power In Connector and LED Profinet IO Port 2 Connector and LED ID-NET Connector and LED Auxiliary Port Connector Trigger Connector and LED IP Address Selectors (last octet) I/O Connector and LED Reading Device Connector...
  • Page 2: Services And Support

    - Material Return Authorization LEGAL NOTICES © 2012 Datalogic Automation S.r.l.  ALL RIGHTS RESERVED.  Protected to the fullest extent under U.S. and international laws. Copying, or altering of this document is prohibited without express written consent from Datalogic Automation S.r.l.
  • Page 3 QLM700 INSTALLATION MANUAL DESCRIPTION The QLM700 Profinet IO Gateway is an active connection module which can be used in Standalone or ID-NET™ Master Multidata, or Master Synchronized layouts. It provides a fast and efficient way to cable both an Profinet IO network and an ID-NET™ network using standard cables.
  • Page 4: Package Contents

    QLM700 INSTALLATION MANUAL PACKAGE CONTENTS Verify that the QLM700 and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes:  QLM700 Gateway  This Installation Manual  Mounting screws and washers (2) ...
  • Page 5: Mechanical Installation

    M5 threaded holes.  QLM700 can also be mounted to a Bosch Frame using the two M5x20 screws included in the package, plus two specific commercial T-nuts (for example the Bosch Rexroth T-nut 10 M5, cod. 3 842 530 283).
  • Page 6: Electrical Connections

    QLM700 INSTALLATION MANUAL ELECTRICAL CONNECTIONS CONNECTORS PWR-IN (Power In) ID-NET (Out) M12 5P Male M12 5P Female (A-coded) (A-coded) Function Function Shield TRG (Trigger) M12 4P Female M12 8P Female (A-coded) (A-coded) Function Function +V (I/O) +V (I/O) -V (I/O)
  • Page 7 PWR-IN is a 5-pin Male A-Coded M12 connector. Input power must only be supplied to the QLM700 at the PWR-IN connector; from there it is internally distributed to the connected reading device, the ID-NET™ network and all the I/O devices.
  • Page 8 QLM700 INSTALLATION MANUAL Pins 2 and 3 on the ID-NET connector carry the same power supply lines present on pins 1 and 3 of the PWR-IN connector; however power must only be supplied to the QLM700 through the PWR-IN connector.
  • Page 9: Aux Connector

    QLM700 INSTALLATION MANUAL ETH1 CONNECTOR ETH1 is a 4-pin Female D-Coded M12 connector. It is used to connect the QLM700 to a Profinet IO network in either Daisy-Chain bus, or Star topologies. ETH2 CONNECTOR ETH2 is a 4-pin Female D-Coded M12 connector. It is used to connect the QLM700 to a Profinet IO network in either Daisy-Chain bus, or Star topologies.
  • Page 10 QLM700 INSTALLATION MANUAL 10) Preset the Node Address of the QLM700, as shown in the Profinet IO Network Address Selectors paragraph. 11) Switch on the power supply; after a while (the system needs some seconds to boot), and if the Profinet IO Host is ready and has correctly recognized the QLM700, the green Network Status and Module Status LEDs below both ETH1 and ETH2 M12 connectors should be turned on.
  • Page 11: Indicator Leds

    PWR-IN / ID-NET The Power LEDs are blue when power is correctly applied to the QLM700. These LEDs are red if power polarity is incorrect. In this case the QLM700 and the connected reading device are protected. If external I/O devices are powered through QLM700 (connected to +V I/O and -V I/O), they are not protected from polarity inversion.
  • Page 12: Typical Layouts

    In a daisy chain topology, the Profinet IO network from the Host is connected to one of the two QLM700 Profinet IO ports. The other Profinet IO port connects either to the next Profinet IO node or is left unconnected (sealed by the protection cap).
  • Page 13 Matrix 410™ DS4800 protection to next Profinet IO CBL-1480-xx CBL-1480-xx node Profinet IO PLC (Host) ID-NET™ Multidata Network - DS4800 Master with QLM700 + mixed Slaves with QL300s QL100 Configuration PC CBL-1490 CBL-1480-xx Profinet IO Node ID-NET™ Slaves ID-NET™ Master READY...
  • Page 14: Technical Features

    0.3 - 0.2 A Maximum Distributed Current Allowed  ID-NET™ 4.0 A max Limited Current Consumption  QLM700 + reading device 1.85 A max  Trigger + I/O device 0.75 A max (see related device manuals) Inputs: Input1 (TRG), Input 2...
  • Page 15: Power Supply

    LPS power source. Total power consumption is given by adding the QLM700 power consumption to that of all the devices powered through the QLM700 (reading device, P.S., I/O). Refer to the manual of the connected devices for details about CAUTION minimum/maximum supply voltage and power consumption.
  • Page 16: Declaration Of Conformity

    EC-128 DECLARATION OF CONFORMITY Rev.: 2 Pag.: 1 di 1 Datalogic Automation S.r.l. Via Lavino 265 40050 Monte San Pietro Bologna - Italy www.automation.datalogic.com declares that the QLxxx and QLMxxx; Connection module and all its models are in conformity with the requirements of the European Council Directives listed below:...