Glow-worm Easicom 28 Instructions For Use Manual

Glow-worm Easicom 28 Instructions For Use Manual

Easicom 28; easicom 24 water heater
Hide thumbs Also See for Easicom 28:

Advertisement

condens

Instructions for Use

Easicom 24
G.C. No. 47-019-18
Easicom 28
G.C. No. 47-019-19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Easicom 28 and is the answer not in the manual?

Questions and answers

Summary of Contents for Glow-worm Easicom 28

  • Page 1: Instructions For Use

    Instructions for Use Easicom 24 G.C. No. 47-019-18 Easicom 28 G.C. No. 47-019-19...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS READ CAREFULLY BEFORE USING Read me ....................3 Welcome ..................3 Guarantee Pack ................3 Servicing ..................3 Benchmark..................3 Quick reference guide ..............4 Introducing your appliance ..............4 Appliance description ..............4 Accessories ................... 4 Product documentation ................
  • Page 4 TABLE OF CONTENTS ANY ASSISTANCE? Fault Finding ..................12 Appliance safety devices................ 13 10.1 Boiler Shutdown ................13 10.2 Protecting against frost ..............13 10.3 Condensate Drain Blockage ............13 10.4 Safety Discharge Valve ..............13 Appliance maintenance and servicing ............. 14 11.1 Cleaning ..................14 11.2 Regular servicing ................14 11.3...
  • Page 5: Read Carefully Before Using

    Number on the Benchmark Checklist. Benchmark • Please read these instructions and follow them carefully for the safe and Glow-worm is a licensed member of economical use of your boiler. the Benchmark Scheme which aims to improve the standards of installation and...
  • Page 6: Quick Reference Guide

    For increased system compatibility and Appliance description increased energy saving with intelligent control Glow-worm offer a range of The Easicom range of boilers are designed controls dedicated to work using a unique for use as part of a sealed water central communication system - eBus.
  • Page 7: Explanation Of Symbols

    Only competent persons are allowed to tempering valve. work on the appliance. • Never tamper with safety devices. - 5 - 0020140414_01 - 02/12 - Glow-worm...
  • Page 8: Safety Regulations

    Servicing/maintenance should be carried Glow-worm. out by a competent person approved at the time by the Health and Safety Executive, Any alteration not approved by Glow-worm, in accordance with the rules in force in the could invalidate the certification, boiler countries of destination.
  • Page 9: Guarantee / Responsibility

    - Any defects in the system to which the appliance is connected. Detailed guarantee - Any defects caused by inadequate frost Thank you for installing a new Glow-worm protection. appliance in your home. - Any deterioration or maladjustment Glow-worm appliances are manufactured to...
  • Page 10: Recycling

    IMPORTANT: The recycling of the packaging must be carried out by the qualified professional who installed the appliance. • Recycle the appliance packaging by sorting the waste to separate those which can be recycled (cartons, plastics...) from those that cannot (strapping ...). - 8 - 0020140414_01 - 02/12 - Glow-worm...
  • Page 11: How To Use Your Appliance

    HOW TO USE YOUR APPLIANCE 8 Overview Fascia Anolouge clock Reset button Mode selection button Temperature adjustment Display Display Heating Domestic hot water DHW/CH water temperature/CH pressure Symbol indicates temperature or pressure Symbol indicates burner ON - 9 - 0020140414_01 - 02/12 - Glow-worm...
  • Page 12: Switching On

    Minimum an initiation cycle that lasts a few seconds, Maximum the appliance is ready to function. NOTE: If a Glow-worm outdoor sensor or Turning off Glow-worm intelligent controls are fitted, the temperature of the water in the heating • Switch the power supply off to your circuit is calculated by the boiler.
  • Page 13: Timer

    • Position the selector switch (5) to the middle position 24 hour clock dial The heating will now operate your chosen Minute hand programme. Off tappets to the inside On tappets to the outside Selector switch Triangle - 11 - 0020140414_01 - 02/12 - Glow-worm...
  • Page 14: Any Assistance

    Glow-worm power comes back Service. Electrical on, the appliance boiler circuit automatically stops interrupted comes back into working service. If the fault persists, contact your Installation/ Servicing company or Glow-worm Service. - 12 - 0020140414_01 - 02/12 - Glow-worm...
  • Page 15: Appliance Safety Devices

    • To restart the boiler, press the reset off, contact your Installation/Servicing button, see chapter «Quick reference company or Glow-worm Service to have the guide». installation drained or to have the heating If the boiler fails to resume normal...
  • Page 16: Appliance Maintenance And Servicing

    The name and model badge is on the front case. DANGER: • If in doubt seek advice from the local Incorrect or inadequate servicing gas company or Glow-worm’s own can severely affect the safety of the service organisation using the telephone appliance and can lead to injury. number below. We recommend that your appliance is Tel: 01773 828100 serviced every year.
  • Page 17: Tips For Saving Energy

    13 Contact your after-sales organisation Customer service call Tel: 01773 828100 Technical helpline Tel: 01773 828300 - 15 - 0020140414_01 - 02/12 - Glow-worm...
  • Page 20 GLOW-WORM GLOW-WORM Nottingham Road, Nottingham Road, Because of our constant endeavour for Because of our constant endeavour for Belper, Derbyshire. Belper, Derbyshire. improvement, details may vary slightly improvement, details may vary slightly DE56 1JT DE56 1JT from those shown in these instructions.

This manual is also suitable for:

Easicom 24

Table of Contents

Save PDF