Stay Away Test System Weekly press both No Delay Silent Pager press both Features System Menu press both Status Lights Bypass 466–1667 Revision B Getting to Know Your Security System Auxiliary Panic Alarm Overview Siren Time-out Access Codes Communicating with the Panel Instructing the Panel System Master Code How Your System Communicates with You...
Commands at a Glance To do this: Press: Disarm the system. + Code Cancel an accidental alarm. Arm to Level 2—STAY. + Code Arm to Level 3—AWAY. + Code Send a police alarm. Press and hold both POLICE buttons for 2 seconds. Send an auxiliary alarm.
Your system may also use wireless, ETTING TO ECURITY YSTEM handheld touchpads that can be carried This manual describes how to operate your system. It describes from room to room. basic arming and disarming commands as well as how to program system features.
Instructing the Panel Pager Notification Not just anyone can walk up to a touchpad and operate your secu- Your system can dial the phone numbers of three different pagers rity system. Before the system will process most commands, users to notify pagerholders of events they may want to be aware of. are required to enter a pre-programmed 4-digit access code.
(See the section on “Preventing Accidental Alarms” on page 6 if To arm to Level 2—STAY using a touchpad: you would like to be able to leave quickly when the system is Close all protected perimeter doors and windows. armed.) Press at any touchpad.
SING THE HIME EATURE Guidelines for Preventing Accidental Alarms Turning on the Chime feature is like having bells on every protected door and window. When this feature is on, sirens and speakers sound 2 beeps whenever anyone opens a protected door or win- Following these guidelines will go a long way toward pre- venting accidental alarms.
Extended Delay XIT AND NTRY ELAY IMES In some situations, additional time is needed to arm or After arming your system, you need time to exit the disarm the system from, for example, a protected out- building so you won’t set off an alarm. Likewise, upon side gate or door.
Auto STAY Arming Feature Bypassing a Sensor Directly The Auto STAY Arming feature helps cut down on false alarms in Use this method if the system is armed and you would like to open the event that you arm the system to 3—AWAY, but fail to leave a window without disarming.
System Alarm Sounds HECKING THE TATUS OF YSTEM The sirens and touchpads in your system emit alarm sounds when- Checking the system status means finding out about the current ever an alarm occurs, either by a sensor or panic button activation. condition of your system.
Using the Programming Menus Auxiliary Panic Alarm Some system settings can be changed by you, the user, while other The Auxiliary panic alarm sounds from interior sirens only. It is typi- settings must be changed by the installer. cally set up by your security dealer, based on your specific needs. To change system settings, you’ll use the System Master code to On monitored systems, the central station responds by calling the enter a series of programming menus.
Assigning the System Test Attribute DJUSTING YSTEM OUNDS AND OUCHPAD RIGHTNESS System Tests is a user code attribute that allows the user to perform system tests. If the user code does not have this attribute turned on, the user will not be able to perform phone or sensor tests. Arming Your System Silently To assign the System Testing to a user: Use the Silent Arming feature to arm your system without disturb-...
Adjusting the Touchpad Beeps OTIFICATION BY AGER The frequency or pitch of chime and trouble beeps from each fixed Your system can notify up to three different pager phone numbers English touchpad can be adjusted individually to a more desirable to report system events.
Event Code in Page your provider to see exactly how your account number will appear on your pager. This part of the page let’s you know what has happened. Table 1. Event Codes in Pages Streamlining the Page Code Indicates If you feel that it is not necessary to see your account number with each page from your system, you may elect to have the Streamlin- A sensor has been restored to its non-alarm state...
ATCHKEY AGING SING THE ANEL OWNLOAD EATURE The Latchkey paging feature allows up to three pagerholders to be To download to the panel is to replace the old information in it with notified when the system is disarmed. Latchkey pages do not report new information.
Manual Tests ESTING THE YSTEM The automatic tests your system performs provide continuing reas- The system contains a test mode that allows you to test sensors and surance that it is working properly. There are also weekly system panic signals without creating false alarms. Test your system weekly, tests you can do yourself as an added safeguard.
Device Test procedure Touchpad Result Glass guard sensor Tap the glass 3 or 4 inches from the sensor. Zones nn OK (Not UL investigated) SENSOR nn OK Freeze sensor Apply an ice cube wrapped in plastic to the sensor. Zones nn OK (Not UL investigated) Do not allow the sensor to get wet.
Page 17
I can’t arm my system. • The sensor you’re trying to bypass may not be active in the cur- rent arming level. For example, an interior motion detector will Try the following: not be active in Level 2—STAY. • If arming to Level 2—STAY or Level 3—AWAY, make sure all moni- •...
ODES PPENDIX HEETS The tables below provide space for you to record user codes and the attributes of each. If you would like the Latchkey attribute It contains specific information about the setup of your system. changed for any code, contact your dealer. The User Sheets should be completed by the installer and the user.
Page 19
Keychain Touchpad 3 OUCHPAD NFORMATION Status beeps and Key beeps are programmable by the installer. The Silent Arming feature is user–programmable. Protest beeps upon bypassing will always sound. Status Location of TP Beeps Beeps On/Off On/Off On/Off On/Off Keychain Touchpad 4 On/Off On/Off On/Off...
Page 20
RMING NFORMATION AGING For what events will the central station or pagers be notified? Delay Doors and Delay Time Settings Pagers When the system is armed, enter and exit the premises only CS 1 CS 2 through designated delay doors. Reporting Features The time allowed to enter the premises and disarm the system is the Entry Delay time.
PPENDIX LANNING FOR MERGENCIES Develop plans for a variety of emergency situations. Periodically discuss and rehearse emergency plans that include the following: • Understand how to use your security system. • Know the normal state of doors and windows; open, closed, or locked.
Page 22
If Your System Needs Service Company Name _____________________________ If you have any questions about your security system or if it ever Address ____________________________________ needs servicing, please contact your security dealer. City _______________ State _____ Zip __________ Phone Number (_____) _______________________ Contact Name _______________________________ Floor Plan of Your Home or Business...
Examples of Programming Using Menus PPENDIX Here are two examples of programming using system menus. The ROGRAMMING YSTEM examples describe each step involved in programming a user code You can program the following items on your system: and in erasing a user code from a fixed English touchpad. •...
Page 24
At a touchpad, press Press to move forward in the menu. Press to turn a feature off. System displays: Press to move backward in the menu. Press to turn a feature on. Enter the System Master code. Press ‚ to back out of the menu. ‚...
Using Programming Shortcuts The table below lists: How to enter the programming menus. A programming shortcut is a number that gets you to a particular User programming tasks. spot in the programming menus. A series of shortcut numbers takes you directly to the feature or code you want to change. The sequence of keypresses to take you to the task.
Page 26
1. Enter 2. Choose programming task. ‚ ‚ 4. Enter value 5. Secure 6. Exit 3. Enter programming or choice. choice. programming then key menus: menus. sequence. Change User code 08 1 0 0 8 0 4-digit code Direct Bypassing for User 08 1 0 0 8 1 (Off) or (On)
Page 30
Declaration of Conformity (DoC) ITI is a registered trademark of Interactive Technologies, Inc. Concord, Interactive Technologies, Inc. declares that the ITI model no. 60-792-95R is SuperBus, SnapCard, and ToolBox are trademarks of Interactive Technolo- in conformity with Part 15 of the FCC Rules. Operation of this product is gies, Inc.