Download Print this page
McPhiben CTX Series Instruction Manual

McPhiben CTX Series Instruction Manual

Self-testing/self-dianostic

Advertisement

mcPhilben
Self-Testing / Self-Dianostic
FRONT COVER ASSY
LAMP
CABLE
CEILING MTG
SCREW HOLES
BACK-PLATE ASSY
Flexible conduit only
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Do not use outdoors.
Do not mount near gas or electric heaters.
Do not let power supply wires touch hot surfaces.
Equipment should be mounted in locations and at heights where it will not readily be subjected
to tampering by unauthorized personnel.
The use of accessory equipment not authorized by the manufacturer may cause an unsafe
condition.
Do not use this equipment for other than its intended purpose.
Service of this equipment should be performed by qualified service personnel.
No rigid conduit.
test
MAIN PCA
ELECTRONICS
BATTERY
STRAP
TRANSFORMER
OUTPUT CABLE
No rigid conduit

IMPORTANT SAFEGUARDS

SAVE THESE INSTRUCTIONS
THERMOPLASTIC EMERGENCY
LIGHTING PRODUCTS
BATTERY
TRANSFORMER
CTX Series
INSTRUCTION MANUAL
p/n: 787625460
OPERATOR PANEL
Circuit Assembly Code
T 1 Std Local Lamps Only
T 2 Local & Remote-A Lamps
Options
TD Re-strike TimeDelay
RC Remote Control

Advertisement

loading

Summary of Contents for McPhiben CTX Series

  • Page 1: Important Safeguards

    CTX Series test mcPhilben INSTRUCTION MANUAL p/n: 787625460 THERMOPLASTIC EMERGENCY LIGHTING PRODUCTS OPERATOR PANEL Self-Testing / Self-Dianostic MAIN PCA FRONT COVER ASSY ELECTRONICS BATTERY STRAP LAMP CABLE BATTERY CEILING MTG SCREW HOLES TRANSFORMER Circuit Assembly Code T 1 Std Local Lamps Only T 2 Local &...
  • Page 2: Installation

    INSTALLATION Transformer Inputs: TO OPEN COVER TO OPEN LAMP ================= BLACK - 120V WHITE - Common RED - 277V IMPORTANT NOTE: REMOVE THE INPUT POWER IMMEDIATELY IF ALL RED LED’S ON THE OP-PANEL FLASH: This indicates that the input power is incorrectly wired, and needs to be corrected.
  • Page 3: Normal Power-Up Sequence

    Normal Power-Up Sequence APPLY INPUT IMPORTANT NOTE: POWER REMOVE THE INPUT POWER IMMEDIATELY IF ALL RED LED’S ON ~0/sec THE OP-PANEL FLASH. This indicates that the input power is incorrectly wired, and needs to be corrected. IF 277 is applied to the 120 tap for more than 7/sec, then the fusable-link may open requiring the transformer ARE ALL to be replaced.
  • Page 4: Wiring Information

    NORMAL OPERATION / MANUAL TESTS OP-PANEL INDICATORS / OPERATION: GREEN - Status: Solid indicates system normal and charging current from the input source is available. NOTE: To reset/cancel a test, simply press the button once during any test. 1 Press: performs a 5/sec brief test, all lamps operating from battery only. 2 Presses: performs a 1/min test, all lamps operating from battery only.