1. SPECIFICATIONS * DSA-240L-R MODEL DSA-240L-R ITEM Function Cooling Class Power AC 220V/ 60Hz Capacity 7,030 Btu/h 24,000 Dehumidification Running Current 11.7 Electrical Data Power Input 2,500 Type Recipro Compressor Model AWG5530EXC Capacitor 45µF/ 400VAC Division Indoor Unit Outdoor Unit...
Page 4
* DSA-240LH-R MODEL DSA-240LH-R ITEM Function Cooling & Heating Class Power AC 220V/ 60Hz Capacity 7,030 Btu/h 24,000 Dehumidification 2.67 Running Current 11.5 / 11.8 Electrical Data Power Input 2,500 / 2,550 Type Recipro Compressor Model AWG5530EXC Capacitor 45µF/ 400VAC Division Indoor Unit Outdoor Unit...
3. OPERATION PARTS OF NAME AND FUNCTION * DSA-240L-R/LH-R Indoor Unit Display Switch Panel Remote Control Signal Receiver This place is the part to receive the signal if it receive the signal, you can hear the signal “beep. “beep, beep.”...
Page 8
* DSA-240L-R/LH-R Connection wire Air Inlet Drain Hose Air Outlet Connection Pipe...
REMOTE CONTROLLER * DSA-240L-R Name of Each Button Display AUTO Displays information pertaining to unit. ON/OFF Button Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower FAN SPEED Button the desired temperature. Press to select the fan speed (High "...
Page 10
* DSA-240LH-R Name of Each Button Display AUTO Displays information pertaining to unit. ON/OFF Button Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower FAN SPEED Button the desired temperature. Press to select the fan speed (High "...
Page 11
R E M O T E C O N T R O LLE R D I S P LA Y * DSA -2 4 0 L-R MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat) Lights to indicate the mode selected. AUTO FAN Indicators HOUR FAN DIRECTION Indicators Lights to indicate Lights to indicate the ON OFF...
Page 12
* DSA -2 4 0 LH -R MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat) Lights to indicate the mode selected. AUTO FAN Indicators HOUR FAN DIRECTION Indicators Lights to indicate Lights to indicate the the fan speed. ON OFF AUTO fan direction. TIMER NATURAL NATURAL Indicator Lights to indicate the speeds simulating a loreeze.
Page 13
DESCRIPTION OF FUNCTIONS OFF-Timer If you set time in OFF-Timer Mode, the unit will stop at the set time. Unit ON Unit OFF SET Time HOUR ON-Timer If you set time in ON-Timer Mode, the unit will run at the set time. Unit ON Unit OFF SET Time...
Page 14
Fan Speed (Indoor Unit) (1) Motor speed (High speed, midium speed, low speed). (2) Remote controller setting fan speed. (Auto, L, M, H, Natural) (3) Relation of operating mode between fan speed. (legned: X-no relation) DEHUMI- HEAT FAN ONLY COOL AUTO QUICK DIFICATION...
Page 15
Sleep M ode (1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature. (The unit will automatically turn off after 4 hour) (2) For changing the temperature. +0.5 C +0.5 C - 0.5 C +0.5 C - 0.5 C...
After the indoor fan is operated for 20 seconds in the Auto Mode the unit will operate automatically by selecting operating Mode according to the room temperature (RT: Room temperature) ROOM TEMPERATURE OPERATING MODE FLAP POSITION DSA-240L-R Cooling Cooling Position > DT-2°C DSA-240LH-R...
Page 17
Dehum idifica tion M ode Desired temperature < Room temperature Outdoor Fan, Compressor : ON Indoor Fan : Low speed Desired temperature Room temperature Compressor : 3 min/ON, 5 min/OFF Fan Speed : low speed < = Room temperature 18 C Compressor : OFF Fan speed : Low speed A ir Discha r ge Direction(only rem ocon opera tion)
Page 20
MAIN ELECTRIC PARTS * DSA-240L-R PART NAME PART CODE SPEC. QUANTITY REMARK Fan Motor 3108007500 IC-9430DWKG7A Fan Motor Capacitor 3106902400 2.0uF 400VAC Indoor Fuse 5FVLB3152L 250V 3.15A Transformer 5EPV050120 230V/50Hz Unit Stepping Motor 3108007600 GSP-24RW-062 Terminal Block 3108912320 SN-DBW-062 Compressor...
5. REFRIGERANT CYCLE Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter. Model Name DSA-240LH-R Contents IDØ2.0 x ODØ3.2 x 600L Cool Capillary Tube Heat IDØ2.0 x ODØ3.2 x 300L Charge Quantity 2,200 g...
6. CONTROL BLOCK DIAGRAM * DSA-240L-R Operating Mode Unit on lamp Remote Signal receiver Fan Speed Air clean lamp Emergency Timer Selection Quick lamp Flap Position Operation Timer lamp Temp. Setting ON/OFF Room air temp. SLEEP Indoor coil temp. REMOCON...
Page 23
* DSA-240LH-R Operating Mode Unit on lamp Remote Signal receiver Fan Speed Air clean lamp Emergency Timer Selection Quick lamp Flap Position Operation Timer lamp Temp. Setting ON/OFF Room air temp. SLEEP Indoor coil temp. REMOCON Outdoor coil temp Circuit for signal receiver A/D converter lnitialization Beeper...
7. ELECTRIC CIRCUIT DIAGRAM ELECTRIC CIRCUIT DIAGRAM * DSA-240L-R Indoor Unit Fan Motor TERMINAL BLOCK I.D.C SWING MOTOR TRANS- FORMER TRIAC COMP. RELAY OVERLOAD Display Part PRO- TECTOR Control Part OUTDOOR UNIT COMPRESSOR ROOM AIR FAN MOTOR SENSOR Signal Receiver...
Page 26
Description 1. After the power ON/OFF button is pressed once, the relay and triac are turned ON or OFF per the remote control setpoint. 2. If the power ON/OFF button is pressed once more, the relay and triac are turn off and the unit stops operation.
Page 28
Note 1) Neither indoor unit nor outdoor unit runs. Check the following points first. (There are following case in normal operation) a. Is the timer mode set the "timer ON". b. Is the timer mode set the "timer-OFF" and the time had passed? Neither outdoor fan nor compressor runs while indoor fan runs.
Neither Indoor Unit nor Outdoor Unit Runs Confirm following statement. When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate. Check the function select switch. Is it timer mode? The function select switch locate the sleep mode and is the setting time over? Is the setting mode DEHUMIDIFIER mode? When the unit is DEHUMIDIFIER mode while in the auto mode, the outdoor unit and indoor unit does not run.
Page 30
Outdoor Unit Runs but Indoor Fan Do Not Run Check rotation of indoor fan Check the Fan Motor bearing and fan Rotate indoor fan by hand Check the power P.C.B. Rating voltage Check input Voltage of Fan Motor connector at power P .C.B under 90% The circuit for triac control Rating Voltage more than 90%...
Page 31
Outdoor Fan and Compressor Do Not Confirm following statement. When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate. Is the setting temperature proper? Is the unit during 3min. Time delay of compressor. During frost prevention of lndoor unit. During dehumidifier mode.
Page 32
Only Compressor Do not Run - Check the following at cooling mode Check the control P .C.B Rating voltage Check the voltge between the circuit for relay of indoor unit terminal less than 90% driving. Rating voltage more than 90% Check the connecting Rating voltage wire between indoor...
Page 39
Power Supply(1) AC 220V 275V 7812 104K 7805 FUSE1 VI VO VI VO 3.15A 100µF 1000µF 470µF POWER TRANS DESCRIPTION DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac Driving Photo Triac, Buzzer Driving Swing, Sweep Motor. AC voltage of secondary Power Transformer is rectified by Bridge Diode, and it is filtering by Main Condensor CE1.
Page 40
Sensor(3) Room temperature and Evaporator temperature Sensor Input 070LH,091LH 182LH, 240LH O/C SENSOR CN10 12.7kF MICOM I/C SENSOR 12.7KF ROOM SENSOR 12.7KF DESCRIPTION Number 24, 25 of Micom is Terminal of A/D convertor Input. Room temperature and Evaporator temperature is sensing by change of Thermister Resistance, Micom is put in 5V by ratio between R10 (12.7KΩ) and R11 (12.7KΩ).
Page 41
Triac Driving(4) AC 220V TLP561 130µH MICOM 0.1µF 120Ohm SM3JZ47 KID 65004 TO MOTOR 1/2W DESCRIPTION Number 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is supplied Trigger Signal. Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Time delay part according to Fan Speed.
Page 42
Remote Controller(5) DESCRIPTION Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gotten fid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1. But in Secondary Wave Custom Code is Reversed Face. 4.5ms 16bit 24bit...
Page 43
Micom Power Supply(7) VDD 42 CC11 10µF MICOM 8MHz CC13 DESCRIPTION MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.
Page 44
Reset(8) MICOM 5.6K 7042P 10.3 4.7uF/50V DESCRIPTION Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect Power ON and Voltage less than 4.25V, and then send Reset Signal. Vcc (+5V) 4.25V DELAY TIME FOR POWER ON...
Page 45
Function Selecting(9) F3 104Z 4A 103J MILD/HIGH HEAT/COOL MICOM F5 104Z 103J heat/low cool/low model heat/high cool/high monitoring DESCRIPTION Selecting function is as following table 9-1. * When power source is put at fist, Funtion selection input is recognized. And when the unit is running the microcomputer ignore variation of funtion selection input. MILD –...
Page 46
Zero Crossing Detect(11) KRC120M MICOM TRANS OUTPUT 5.6K DESCRIPTION It defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom. Detail Driving is as following Fig 11-1. R19 is Resistance to limit current. AC18V Number 31 of...
Page 47
Stepping Motor Driving(12) CN13 Ø 1 Ø 2 FOR SWING MICOM Ø 3 Ø 4 KID65004 DESCRIPTION There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method. It is driving as following Fig 12-1. (Ring Count Method of 8 Status) Ø...
Page 48
REMOTE CONTROLLER ASSMBLY FUNCTIONAL TEST METHOD TEST START Power supply again Power Supply Is Display at the beginning ON? Select ON/OFF button Check the Following BATTERY SPRING MICOM Is Display at the beginning ON? Select Mode button > Is it normal? ERROR Select FAN SPEED button >...
Page 49
ERROR Is LCD display OFF? Select TIMER ON Button ERROR Is it normal Select Timer Enter Button ERROR display? TIMER Select CANCEL Button ERROR Is all display OFF? Select ON/OFF Button Select OFF (Timer) Button (0.5~24 HOUR) ERROR Is it normal? Select SLEEP Button SLEEP MODE ERROR...
10. DISASSEMBLY INSTRUCTIONS INDOOR UNIT * DSA-240L-R/LH-R PROCEDURES PHOTOS 1. Stop the Air conditioner and disconnect the power cord from the wall outlet. Fig 1 2. Removing the Insert Grille and Frame Grille. (Fig 1~2) 1 Draw up the Insert Grille and remove it.
OUTDOOR UNIT * DSA-240L-R/LH-R PROCEDURES PHOTOS 1.Stop the air conditioner and dis connect the wire from in door unit to out door unit. 2. Disassemble the case. (Fig 1~2) Fig 1 1 Remove the Top Panel. (Loosen two screw and remove six hook) 2 Remove the Front Cabinet.
Page 56
* DSA-240L/LH PART LIST (INDOOR UNIT) Caution: In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr) PART CODE PART NAME Q'TY...
Page 57
* DSA-240L/LH PART LIST (INDOOR UNIT) PART CODE PART NAME Q'TY SPEC REMARK 2150013200 AL FOIL EMI AL100P (W100XL100) 3106902400 CAPACITOR SH.M.B 2.0MF 400V 3102797910 HARNESS EARTH GREEN/YELLOW L170mm 3104896300 SENSOR ID ASSY NTM-KD43C-D1D2 L450, L330 3108912320 TERMINAL BLOCK SN-DBW-4P 5EPV050120 TRANSFORMER DWA-220B...
Page 59
* DSA-240L PART LIST (OUT DOOR UNIT) Caution: In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr) PART CODE PART NAME Q'TY...
Page 61
* DSA-240LH PART LIST (OUT DOOR UNIT) Caution: In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr) PART CODE PART NAME Q'TY...
* DSA-240L Caution: In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr) PART CODE PART NAME Q'TY...
Page 65
* DSA-240LH Caution: In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr) PART CODE PART NAME Q'TY...