SEPARATION TANK
INSPECTION
Weekly Inspection:
Skimmer basket - remove debris. For systems with
bypass valve, make sure separation tank is not under pressure.
Bi-Yearly Inspection:
Check separation tank/return line bypass valve for
proper sealing as follows: With filter valve in `FILTER' position and separation
tank cover off, start pump. No water should enter separation tank from lower
port. If water does enter, stop pump and inspect bypass valve for leaks and
debris. Clean or replace as necessary.

WINTERIZING

1. Open air release valve; open all system valves. Position multiport valve
between port positions to allow air passage to all ports.
2. Remove all drain plugs from trap, pump, valve, filter, and separation tank.
3. Drain all piping and cover system with plastic or tarpaulin to keep it dry.
8