MT107-100. Keep this manual handy for future These limits are designed to provide reasonable reference. These safety instructions are to ensure protection against harmful interference when the the long life of your MT107-100 and to prevent fire equipment operated commercial and shock hazard.
FEATURES/ MT107-100 DESCRIPTION 64 X 64 Matrix Engine 300MHz GENERAL The MT107-100 is a 64x64 Matrix Engine used for Inputs connecting audio and video signals. The Matrix Input Connectors 8 BNC Female Engine has a built-in 8 video inputs and 8 video Outputs outputs.
VIDEO / SYNC SWITCH SETTINGS Set the V/S (Video/Sync) switch to match the type of output signal being used. NOTE: There are eight (8) switches, one per each output. ALTINEX, INC 285-0423-002 S = SYNC V = VIDEO R29 R13 R100...
[ Function , Card ID , Unit ID ] available slots in the Multi-Tasker™ Enclosure in order to connect to the bus. Example: [VERC3U2] Make sure that the MT107-100 cards fits VER = Function into place. = Card or Group ID Step 6.
Page 11
Ui = Unit ID (i = # from 0 to 9) This command sets the matrix configuration for Example: the matrix engine. There is an MT107-100 card is in slot #2. Send Command Format: the command the Multi-Tasker™ [VERC2] and...
Page 12
MULTI-TASKER™ Number of Inputs: The number of inputs in Default Configuration the configuration, or eight times the number INPUT CARDS OUTPUT CARDS of input cards installed is the maximum. … … If the channel width and spacing are Base Base different, then the number of inputs will be Unit Unit...
Page 13
15b 11b 7b 7b 11b 15b Example 1: SINGLE OUTPUT 16a 12a 8a 8a 12a 16a There is an MT107-100 in slot #10. Turn ON 16b 12b 8b 8b 12b 16b output number 64 by sending the command [ON64C10]. Example 2: ALL OUTPUTS 4.
Page 14
MULTI-TASKER™ 8. [IO] 11. [OUT#S] This command connects an input to an output This command returns the input that is for the current matrix configuration. connected to the specified output. Command Format: [ImmOzzCnUi] Command Format: [OUTmSCnUi] mm = Input (2 digit # from 01 to 64) mm = Output (2 digit # from 01 to 64) zz = Output (2 digit # from 01 to 64) Cn = Engine Card Slot Number...
Page 15
MULTI-TASKER™ 13. […S] – Save Command Format: [SELmmCnUi] mm = Input (2 digit # from 01 to 64) This command will save the configuration command being sent in memory. When Cn = Engine Card Slot Number Ui = Unit ID (i = # from 0 to 9) sending the command [I1O8C4S], after reset or power up, Input 1 will be connected to Output 8 [+] = Increment level by one...
Page 16
MULTI-TASKER™ mm = Input (2 digit # from 01 to 64) Check for a signal on Output 1 of the Engine in Cn = Engine Card Slot Number slot #8 by sending the command [SDO01C8 ]. If Ui = Unit ID (i = # from 0 to 9) a signal present on Output 1, the following feedback will be returned: Example: CHECK ONE INPUT...
Page 17
Ui = Unit ID (i = # from 0 to 9) In order to display the RS-232 commands Example: available for the MT107-100 card in slot 2, send Test the VIS circuit for the Engine Card in the command [HELPC2]. The commands along slot #8.
MULTI-TASKER™ 26. [CLR] Example: Group 5 of Unit ID 1 contains the cards in slots This command clears the members for a single group or for all eight groups. The clear 1, 2 and 19. Read the member data for group 5 of Unit ID 1.
We have carefully tested and have found no Cause 3: RS485 communication error problems in the supplied MT107-100. However, we would like to offer suggestions for the following: Solution 1: Make sure that the card is pushed all the way into the slot. If there is 8.1 LED IS NOT LIT...
Altinex (714) 990-2300. ALTINEX POLICY 9.1 LIMITED WARRANTY/RETURN POLICY Please Altinex website www.altinex.com for details on warranty and return policy. 9.2 CONTACT INFORMATION ALTINEX, INC 592 Apollo street Brea, CA 92821 USA TEL: 714-990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com...
Need help?
Do you have a question about the MT107-100 and is the answer not in the manual?
Questions and answers