Under-the-sink Reverse Osmosis System
System Tested and Certified by NSF International against NSF/ANSI Standard 58 for the reduction of Barium, Cadmium, Copper, Cyst, Hexavalent Chromium,
Lead, Radium 226/228, Selenium, TDS, Trivalent Chromium as verified and substantiated by test data
© Copyright 2006 OMNIFILTER
Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com
Model:
Tested and Certified
by NSF International
293 Wright Street, Delavan, WI 53115
Phone: 1-800-937-6664
RO2000 Series B
www.omnifilter.com
Printed in the U.S.A.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RO2000 Series B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Omnifilter RO2000 Series B

  • Page 1 INSTALLATION & SERVICE MANUAL Under-the-sink Reverse Osmosis System Model: RO2000 Series B Tested and Certified by NSF International System Tested and Certified by NSF International against NSF/ANSI Standard 58 for the reduction of Barium, Cadmium, Copper, Cyst, Hexavalent Chromium, Lead, Radium 226/228, Selenium, TDS, Trivalent Chromium as verified and substantiated by test data...
  • Page 2: Recommended Tools List

    Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 3: Specifications

    TO FEED WATER PRESSURE TANK 2nd STAGE 1ST STAGE SPECIFICATIONS: Please contact your local dealer at: 1st stage: Sediment filter or call OMNIFILTER at 1-800-937-6664. 2nd stage: Carbon filter 3rd stage: TFC membrane 4th stage: Inline carbon filter Auto shut off valve...
  • Page 4: Performance Data Sheet

    12 months Warranty RO2000 Series B Reverse Osmosis Systems are warranted to the original owner to be free of defects in material and workmanship from the date of manufacturing for one year. While testing was performed under laboratory conditions, actual performance may vary.
  • Page 5 99.95% Performance Indication: A sampling kit for analysis of TDS The Omnifilter model RO2000 Series B reverse osmosis system contains a replaceable treatment component critical for effective reduction of TDS (Total Dissolved Solids). The product water shall be tested periodically to verify that the system is performing satisfactorily.
  • Page 6 RO Water to Storage Tank Air Gap Connector Black 1/4" Discharge Water to Air Gap Faucet Discharge Water From Air Gap Faucet Drain Connector Black 3/8" to Drain Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 7 Lock Washer Spacer Washer Connect to 3/8” Connect to 1/4” Black Tubing Black Tubing Stud (Brine Input) (Brine Output) Connect to 1/4” Blue Tubing Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 8 15) The faucet dispensing handle may be pushed and held down for instant water or pulled up into the locked position for continuous flow. Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 9 Connect Fitting Rubber Washer Air gap faucet with installation kit Completed Air gap faucet installation Blue 1/4" tubing Black 1/4" tubing Black 3/8" tubing Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 10 Angle stop shut off valve 3/8" Feed water adapter components Feed water adapter assembly Flex line assembly Solid copper line assembly <Fig. 3> <Fig. 4> Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 11 Use a wrench to securely tighten the hex chrome plated compression nut with the matching compression thread. f) Do not use Teflon tape on this compression connection. Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 12: Step 4: Mounting The Drain Clamp

    See <Fig. 7>. 5) Connect 3/8" black tubing to drain clamp. RO FAUCET DRAIN PIPE MOUNT DRAIN VALVE NEVER MOUNT HERE <Fig 7 <Fig 6> Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 13: Step 5: System Start Up

    I WARNING: Never use hot water or freeze unit. I WARNING: Incorrect installation will VOID the warranty. Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 14: Preventive Maintenance

    If the water flow is OK, then turn on the tank ball valve. After 1 minute, turn off the RO faucet and complete the filter change procedures. Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 15: Troubleshooting

    Fittings are not tightened I Tighten fittings as necessary Leaks Twisted O-ring I Replace a o-ring Misalignment of hole in drain I Realign drain saddle saddle Printed in the U.S.A. © Copyright 2006 OMNIFILTER Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...
  • Page 16 293 Wright Street, Delavan, WI 53115 Phone: 1-800-937-6664 www.omnifilter.com Filters Fast • 866-438-3458 • sales@filtersfast.com • www.filtersfast.com...