Summary of Contents for Crestron CH-LMD1

  • Page 1 Crestron CH-LMD1 Light Motion Detector Operations & Installation Guide...
  • Page 2 This document was prepared and written by the Technical Documentation department at: Crestron International. Oude Keerbergsebaan 2 B-2820 Rijmenam - Belgium Tel: 0032/(0)15 50 99 34 Fax: 0032/(0)15 50 99 40...
  • Page 3 Crestron CH-LMD1 Light Motion Detector Operations & Installation Guide...
  • Page 4: Important Safety Instructions

    • The CH-LMD1 can be used with Class 2 output wiring. Prevent foreign objects from entering the device. All brand names, product names and trademarks are the property of their respective owners.
  • Page 5: Table Of Contents

    Identity Code ....................... 5 Hardware Hookup ....................... 5 Programming Software ......................7 Earliest Version Software Requirements for the PC ........... 7 Programming with Crestron SystemBuilder ..............7 Programming with D3 Pro ................... 7 Programming with SIMPL Windows ................7 Example Program ......................9 Uploading and Upgrading ......................
  • Page 7: Light Motion Detector: Ch-Lmd1

    Light Motion Detector Light Motion Detector: CH-LMD1 Introduction The interface CH-LMD1 contains a sensor for detecting motion and a sensor for measuring the density of light in the internal area and works with the direct binding to a Crestron control via Cresnet.
  • Page 8: Physical Description

    Lightsensor: Range of threshold 0 – 1275 Lux, 5 Lux/step 1. The latest software versions can be obtained from the Crestron website. Refer to the NOTE following these footnotes. 2. Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest Crestron Product Catalog for a complete list of 2-Series control systems.
  • Page 9 CONTROLS & INDICATORS (1) 4-pin 3.5 mm detachable terminal block; Connects to Cresnet control network 24: Power (24 Volts DC) Data Data G: Ground Light Motion Detector: CH-LMD1 • • • • 3 Operations & Installation Guide – DOC. 0005...
  • Page 10: Industry Compliance

    Light Motion Detector Crestron CH-LMD1 Industry Compliance As of the date of manufacture, the CH-LMD1 has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC rules.
  • Page 11: Setup

    Identity Code Personal computer (PC) via Crestron Toolbox™ (refer to “Establishing The Net ID of the CH-LMD1 has been factory set to 4D. The Net IDs of multiple CH-LMD1 devices in the same system must be unique. When setting the Net ID, consider the following: •...
  • Page 12 Light Motion Detector Crestron CH-LMD1 Hardware Connections for the CH-LMD1 6 • • • • Light Motion Detector: CH-LMD1 Operations & Installation Guide – DOC. 0005...
  • Page 13: Programming Software

    Crestron has developed an assortment of Windows -based software tools to develop a Cresnet system. You can create a program to control the CH-LMD1 using the Crestron programming tools D3 Pro™ or SIMPL Windows. Customers whose focus is on lighting systems may prefer to use the D3 Pro software since it is designed especially for creating lighting and environmental system control applications.
  • Page 14 Device Library. • To incorporate the CH-LMD1 into the system, drag the CH-LMD1 from the User module | Project module folders after copying the modules to the User macro folder or the same folder where the project is stored.
  • Page 15: Example Program

    Program Manager is the view where programmers “program” a Crestron control system by assigning signals to symbols. The CH-LMD1 can be viewed by double clicking on the icon or dragging it into Detail View. Each signal in the symbol is described in the SIMPL Windows help file (F1).
  • Page 16: Uploading And Upgrading

    2-Series Control Systems Reference Guide (Doc. 6256). 2. Use the Address Book in Crestron Toolbox to create an entry for the CH- LMD1 using the expected communication protocol (Indirect). Select the Cresnet ID of the CH-LMD1 and the address book entry of the control system that is connected to the CH-LMD1.
  • Page 17 Crestron CH-LMD1 Light Motion Detector connected to the control system. Right-click on the CH-LMD1 to display actions that can be performed on the CH-LMD1. Light Motion Detector: CH-LMD1 • • • • 11 Operations & Installation Guide – DOC. 0005...
  • Page 18: Problem Solving

    Cresnet power usage of the entire chain. If the unit is home-run from a Crestron system power supply network port, the Cresnet power usage of that unit is the Cresnet power usage of the entire run. The wire gauge and the Cresnet power usage of the run should be used in the following equation to calculate the cable length value on the equation’s left side.
  • Page 19: Reference Documents

    Make sure the cable length value is less than the value calculated on the right side of the equation. For example, a Cresnet run using 18 AWG Crestron Certified Wire and drawing 20 watts should not have a length of run more than 333 feet (101 meters). If Cresnet HP is used for the same run, its length could extend to 1250 feet (381 meters).
  • Page 20: Software License Agreement

    This Agreement may only be modified by a writing signed by an authorized officer of Crestron. Updates may be licensed to You by Crestron with additional or different terms. This is the entire agreement between Crestron and You relating to the Software and it supersedes any prior representations, discussions, undertakings, communications or advertising relating to the Software.
  • Page 21 “applets” incorporated into the Software), the accompanying media and printed materials and any copies of the Software are owned by Crestron or its suppliers. The Software is protected by copyright laws and international treaty provisions. Therefore, you must treat the Software like any other copyrighted material, subject to the provisions of this Agreement.
  • Page 22: Return And Warranty Policies

    Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures.
  • Page 23: Gnu General Public License

    License and to the absence of any warranty; and give any other recipients of the Program a copy of this License along with the Program. Light Motion Detector: CH-LMD1 • • • • 17 Operations & Installation Guide – DOC. 0005...
  • Page 24 5. You are not required to accept this License, since you have not signed it. However, nothing else grants you permission to modify or distribute the Program or its derivative works. These actions are prohibited by law if you do not accept this License. Therefore, by 18 • • • • Light Motion Detector: CH-LMD1 Operations & Installation Guide – DOC. 0005...
  • Page 25 THIRD PARTIES OR A FAILURE OF THE PROGRAM TO OPERATE WITH ANY OTHER PROGRAMS), EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Light Motion Detector: CH-LMD1 • • • • 19 Operations & Installation Guide – DOC. 0005...
  • Page 26 Light Motion Detector Crestron CH-LMD1 This page is intentionally left blank. 20 • • • • Light Motion Detector: CH-LMD1 Operations & Installation Guide – DOC. 0005...
  • Page 27 Crestron CH-LMD1 Light Motion Detector Light Motion Detector: CH-LMD1 • • • • 21 Operations & Installation Guide – DOC. 0005...
  • Page 28 Crestron International Operations & Installation Guide – DOC. 0005 Oude Keerbergsebaan 2 Tel: 0032/(0)15 50 99 34 Fax: 0032/(0)15 50 99 40 Specifications subject to www.crestron.eu change without notice.

Table of Contents