This product is designed to be installed and maintained by professional security technicians. Unless specifically noted, Inovonics products are intended for indoor use. This receiver is intended for use with indoor security systems. Use in outdoor applications may impair performance.
Page 2
With the FA116, users can program 16 points into the FA416 without the FA516 display module. The FA116 also has a signal level and signal margin monitoring function, making it very useful for site surveys and troubleshooting.
Page 4
• Technicians can observe output function by monitoring voltages between channel outputs and power on the FA416 or resistance on the FA416R relay outputs. • Transmitter, receiver and output options are factory assigned. They may be changed with the FA116 Executive Programmer or with the FA104 (upgraded C104) programmer.
FA516 Display Module. Visually check the mating of pins and header to make sure that all pins are seated in the header. Note: If the FA516 display is purchased separately from the FA416, it will be packaged with a housing cover and graphic panel to replace the original FA416 cover. (Specify housing type.) Installing the case tamper: Connect leads from the Case Tamper terminal block to a zone on the hardwire panel.
Page 6
Connecting FA416-version receivers to a panel: When the FA416 will be used with a hardwire security panel, the panel will supply 12VDC power and ground to the FA416. Typically, the ground supplied to the receiver is common to the input loops of the hardwire panel. NOTE: Ground from the panel to the receiver MUST be common on the FA416 and FA416D.
2. Select a point number which matches desired transmitter parameters. 3. Press the Advance button on the FA416 as often as needed to turn on the Output LED for the desired transmitter channel. (Output LED 1 equals point # 1, etc.) The LED will blink if the point has not been programmed.
Output Select Jumper. (If the jumper position is changed after transmitters have been programmed, it will be necessary to press the receiver Reset Button.) Activation of an output is indicated by the corresponding Output LED on the FA416 board. The fifth LED is the Global Fault LED.
Deleting points with the FA516: Points 1 through 16 may be deleted. 1. Use the Advance button to show the desired point on the Channel Display. 2. Press the Delete button on the FA416 board. The Programmed LED will change from steady "on" to flashing.
Page 11
Seconds *Only points 1 through 4 can be programmed from the FA416 and FA416R. Points 1-16 may be programmed from the FA416D and FA416DR. The FA116 programmer can be used to change any transmitter options on any receiver for all 16 points.
Page 15
This warranty will not be modified, varied or extended. Inovonics does not authorize any person to act on its behalf to modify, vary or extend this warranty. This warranty will apply to Inovonics Products only. All other products, accessories or attachments used in conjunction with Inovonics equipment, including batteries, will be covered solely by their own warranty, if any.
Page 16
16-channel / 4-relay output with display FA464DR 64-channel / 16-relay output with display Receiver Accessories: FA116 Executive Programmer for FA416 / FA464 / C404 FA516 Display module for FA416 and FA416R FA541 Single-channel form ‘C’ relay module Inovonics Wireless Corporation...
Need help?
Do you have a question about the FA416 and is the answer not in the manual?
Questions and answers