FOOTSWITCH CONNECTION DETAILS

7 – ACTIVE/BYPASS – This switch in the BYPASS position by-passes the EFX Loop
hardware in the amplifier. For proper operation of the EFX Loop, this Switch MUST
be in the ACTIVE position.
8, 9 EFX LOOP – The EFX Loop on the Tomtone Deluxe is a fully buffered tube driven
loop that allows for transparent insertion of effects post-preamp/pre-output. Send
and Return knobs allow for adjustment to and from the loop.
10 – CLASS A RESONANCE – This control does for the low-end as the PRESENCE does
for the high-end. Turning the control fully counter-clock wise will "roll" the low-end
off; while turning the control full clock wise will create a massive bottom. The
RESONANCE control is very functional and powerful to the overall tone and has
more range than most conventional amplifiers.
11 – CLASS SWITCHING– This allows for the Output section to be switched between
Class A/B and Class A (Push Pull). Class A/B mode delivers 40watts offering more
punch and headroom. Class A mode delivers 20watts offering quicker breakup of
the output and higher "chime".
12 – PRESENCE (Class A/B and Class A) – This control rings in the highs through the
Output section of the amplifier. Turing the PRESENCE all the way counter-clockwise
produces a dark, beefy tone. The knob in the middle is "design center" where the
amp was designed and most effective to the overall tone. Turning the knob more
clockwise produces more high-end sparkle. The Presence control is very functional
and powerful to the overall tone and has more range than most conventional
amplifiers.
13 – SPEAKER OUT - ¼" jack that delivers the amplifiers output signal to a speaker
cabinet.
Caution should be taken to ensure that the amplifiers output impedance
(Zout) is configured to match the speaker enclosures input impedance.
14 – Zout - Impedance selector 4,8,16 ohms – This selector should only be changed
when the unit is in the STANDBY or OFF position
ONLY!!!