HV & HW GAS BOILERS
USER'S INFORMATION MANUAL
DESIGNED AND TESTED ACCORDING TO A.S.M.E. BOILER AND PRESSURE
VESSEL CODE, SECTION IV FOR A MAXIMUM ALLOWABLE WORKING
PRESSURE OF 50 PSI, 345 kPa WATER.
Warning: If the information in this manual is not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch. Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
WARNING: Never store combustible materials, gasoline or any product containing
flammable vapors or liquids in the vicinity of the boiler/water heater. Failure to comply
with this warning can result in an explosion or fire causing extensive property
damage, severe personal injury or death!
WARNING: Failure to properly vent this unit can cause excessive amounts of carbon
monoxide resulting in severe personal injury or death!
INSTALLER, THIS MANUAL TO BE AFFIXED ADJACENT TO THE BOILER.
CONSUMER, RETAIN THIS MANUAL FOR FUTURE REFERENCE PURPOSES.
WHAT TO DO IF YOU SMELL GAS:
UMHV3-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HV and is the answer not in the manual?

Questions and answers

Summary of Contents for HydroTherm HV

  • Page 1 UMHV3-1 HV & HW GAS BOILERS USER’S INFORMATION MANUAL DESIGNED AND TESTED ACCORDING TO A.S.M.E. BOILER AND PRESSURE VESSEL CODE, SECTION IV FOR A MAXIMUM ALLOWABLE WORKING PRESSURE OF 50 PSI, 345 kPa WATER. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2 Installation and service must be performed by a qualified Direct all questions to your HydroTherm distributor or installer, service agency or the gas supplier (who contact the HydroTherm Customer Service Department must read and follow the supplied instructions at: 260 North Elm Street, Westfield, MA 01085.
  • Page 3 HV & HW USER’S INFORMATION MANUAL Page 3 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. The HW (constant pilot) appliance is equipped with •...
  • Page 4 Page 4 HV & HW USER’S INFORMATION MANUAL POUR VOTRE SÉCURITÉ LISEZ AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 5 WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • If you cannot reach your gas supplier, call the A. The HV and HW (spark pilot) appliance is equipped fire department. with an ignition device which automatically lights the pilot.
  • Page 6 Page 6 HV & HW USER’S INFORMATION MANUAL POUR VOTRE SÉCURITÉ LISEZ AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 7 FLAME ROLL-OUT SAFETY SHUTOFF SYSTEM BLOCKED VENT SHUTOFF SYSTEM The HV and HW gas boilers are fitted with a flame roll- The HW gas boiler is fitted with a blocked vent shutoff out switch that detects the presence of hot flue gases in system which detects the leakage of combustion the control compartment.
  • Page 8 Carbon monoxide (CO) is a gas which is odorless, colorless and tasteless but is very toxic. If your Hydrotherm boiler is not working properly, or is not vented properly, dangerous levels of CO may accumulate. CO is lighter than air and thus may travel throughout the building. Brief exposure to high concentrations of CO, or prolonged exposure to lesser amounts of CO, may result in carbon monoxide poisoning.