Marquis IDV33 Installation Instructions Manual

Gas fired direct vent room heater inserts

Advertisement

Quick Links

Model Number IDV33-IDV36 Gas Fired Direct Vent Room
Minimum Fireplace Opening Required: 26-1/4"W x 21-3/8"H x 14-3/8"D
Minimum Fireplace Opening Required: 30-3/4"W x 25-5/8"H x 14-3/8"D
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed
exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of
life. Refer to this manual. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962

Installation Instructions

Heater Inserts
Model IDV33
Listed Certified for USA. and Canada
Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91
Model IDV36
Listed Certified for USA. and Canada
Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
FOR YOUR SAFETY
Printed in Canada November 6, 2009 Part # 36IDV-MAN
WARNING: The IDV33/IDV36
Fireplace Insert was designed for
installation in a solid fuel fireplace
that has been installed in
accordance with national,
provincial/state and local building
codes and is constructed of
noncombustible materials. Do not
remove any refractory materials
from any masonry solid fuel
fireplace.
The IDV33/IDV36 Fireplace Insert was
designed for installation in a zero
clearance type listed solid fuel burning
factory built fireplace. It may be
necessary to remove the damper plate,
refractory liners, log grates, glass door,
and screen rails/mesh. Removal of the
smoke baffle is necessary in most
cases.

Advertisement

Table of Contents
loading

Summary of Contents for Marquis IDV33

  • Page 1: Installation Instructions

    Installation Instructions Model Number IDV33-IDV36 Gas Fired Direct Vent Room Heater Inserts Model IDV33 Listed Certified for USA. and Canada Minimum Fireplace Opening Required: 26-1/4”W x 21-3/8”H x 14-3/8”D Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91 Model IDV36 Listed Certified for USA. and Canada Minimum Fireplace Opening Required: 30-3/4”W x 25-5/8”H x 14-3/8”D...
  • Page 2: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 3: Table Of Contents

    Clearance to Combustible Mantels................................14 Venting ........................................15 Installation of Vent Pipe.................................... 16 IDV33/IDV36 Riser Kit and Leveling Instructions ............................. 17 Glass Door Information .................................... 18 Brick and Porcelain Panel Installation ..............................19 Overlay and Double Door Installation ............................... 20 Gas Line Installation....................................
  • Page 4: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 5: Warnings, Installations, And Operations

    Warnings, Installations, and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States.
  • Page 6: Operations And Maintenance Instructions

    • If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5in [37.5mm] or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged with non- combustible insulation after the gas supply line has been installed.
  • Page 7: Idv33 Insert Dimensions And Sizing

    IDV33 Insert Dimensions and Sizing Min. Coverage with Optional I33LK or I33CV Base Unit I33LK I33CV 26-1/4” 34-1/2” 32-3/4” Front Width: Rear Width: 21-1/4” 21-3/8” 24-3/8” 22-3/4” Height: 14-3/8” Depth: I33CV Clean View and Surround Sizes...
  • Page 8: I33Lk Louver Kit And Surround Sizes

    I33LK Louver Kit and Surround Sizes NOTE: The Surrounds shown here are universal and can be used with the I33CV model. Furthermore, the I33S4535B and I36S4736B (1-piece Surround) was designed to be used as a custom cutout surround. Simply trace template and cut out design using the universal surround.
  • Page 9: Idv36 Insert Dimensions And Sizing

    IDV36 Insert Dimensions and Sizing Min. Coverage with Optional I36LK or I36CV Base Unit I36LK I36CV Front Width: 30-3/4” 39” 37-1/4” 25-3/4” Rear Width: 25-5/8” 28-3/4” 27” Height: Depth: 14-3/8” I36CV Clean View and Surround Sizes...
  • Page 10: I36Lk Louver Kit And Surround Sizes

    I36LK Louver Kit and Surround Sizes NOTE: The Surrounds shown here are universal and can be used with the I36CV model. Furthermore, the I33S4535B and I36S4736B (1-piece Surround) was designed to be used as a custom cutout surround. Simply trace template and cut out design using the universal surround.
  • Page 11: I33Cv/I36Cv Front Face And Surround Attachment Installation

    I33CV/I36CV Front Face and Surround Attachment Installation 1. Remove the Top Filler Panel to install vent adapter and venting to the unit. Once this is done, reinstall the Top Filler Panel. Refer to Installation of Vent Pipe for venting information. 2.
  • Page 12: I33Lk/I36Lk Front Face Attachment Installation

    I33LK/I36LK Front Face Attachment Installation 1. Remove the Top Filler piece from the Base unit by unfastening its three [3] screws. This part is not required for the I33LK/I36LK model and therefore can be discarded. However, be sure to keep the screws for fastening the I33LK/I36LK.
  • Page 13: Surround Installation For Idv33/Idv36 Fronts

    Surround Installation for IDV33/IDV36 Fronts 1. Ensure that the I33LK/I36LK Front is installed before continuing with these steps. 2. When installing a 3-piece surround, please note that the side panels must go first. When installing a 1-piece surround, simply skip the instructions for the side panel installation.
  • Page 14: Clearance To Combustible Mantels

    Clearance to Combustible Mantels Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of mantel materials to consider: Combustible and Non-combustible. A Combustible Mantel is one that consists of material(s) that may discolor, combust, or lose its integrity in the presence of heat.
  • Page 15: Venting

    Venting Vertical Venting in Cold Climates In cold climate conditions where temperatures go below -10°C [14°F], we recommend that the chase be insulated and where the vent pipe enters into the attic space that the pipe be wrapped with an insulated Mylar sleeve. This will increase the temperature of the vent and help the appliance to vent properly in cold weather conditions.
  • Page 16: Installation Of Vent Pipe

    Installation of Vent Pipe 1. Remove the Top Filler and adapter plate from the unit by removing the five [5] screws as shown below. (Fig. 3) Attach the vent pipes to the termination with Millpac and 4 screws per pipe joint. Be sure to label the exhaust and intake flex pipes.
  • Page 17: Idv33/Idv36 Riser Kit And Leveling Instructions

    IDV33/IDV36 Riser Kit and Leveling Instructions Leveling Instructions When installing insert it may be necessary to support back of unit. To support back of insert, there are two leveling plates right and left of unit. 1. Measure height required to level unit.
  • Page 18: Glass Door Information

    Glass Door Information Glass Cleaning It will be necessary to clean the glass periodically. During start-up condensation fill form, and cause dust and lint to cling to the surface of the glass. Furthermore, the initial burn cures the paint but also leads to the deposit of a filmy residue. It is therefore recommended that the glass be cleaned two or three times, initially, with non-abrasive common household glass cleansers and warm water.
  • Page 19: Brick And Porcelain Panel Installation

    Brick and Porcelain Panel Installation Brick 1. Remove the glass door. Refer to the Removal of the Glass Door section on page 18 for information. 2. Install rear brick panel first. 3. Install left and right side panels and secure them with brick clips. 4.
  • Page 20: Overlay And Double Door Installation

    Overlay and Double Door Installation IDV33 Overlay This style of Overlay mounts in the square notch cutout as shown in the illustration to the right. Use magnets to secure the overlay to the glass door frame. IDV36 Overlay This style of Overlay mounts to the latching system.
  • Page 21: Gas Line Installation

    Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - B149.1 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A.
  • Page 22: Burner Installation/Removal

    Burner Installation/Removal Burner System 1. Remove glass door assembly and logs (if installed). Be careful with logs as they become fragile after being heated. 2. Remove log supports off burner assembly. 3. The burner or burner assembly can now be removed.
  • Page 23: Fan Installation/Removal

    Fan Installation/Removal Fan System WARNING Electrical Grounding Instructions This appliance is equipped with a three prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this. Before Servicing 1.
  • Page 24: Idv33/Idv36 Insert Burner Component List

    IDV33/IDV36 Insert Burner Component List ITEM PART DESCRIPTION Qty. 3620-105 Burner Bracket 3620-105L Burner Bracket DVI33-107 Burner Pan 3620-111 Pilot Bracket 6000-112-1 Valve Bracket DVI33-125L Burner Trim Plate DVI33-125R Burner Trim Plate DVI33-129 Pilot Shield 4200-132 Burner Hold Down 350-210...
  • Page 25: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING • This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 26: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
  • Page 27 electrical power going to the Receiver module and a fresh set of batteries in the transmitter. Now switch the slide switch to the middle [REMOTE] position and then push the small pushbutton to begin programming. Bring the transmitter close to the receiver and then press the power button [5] on the transmitter.
  • Page 28 Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities. Configuration #2: Remote ON/OFF and manual HI/LO capabilities. OPTIONAL: For units with remote HI/LO capabilities, a modulating servo is required to be installed on the valve. The connectors to this servo must be connected to the Remote Harness as shown in the figure above.
  • Page 29: Ipi Lighting Instructions

    IPI Lighting Instructions WARNING 1. If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 2. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING A.
  • Page 30: Log Placement - Logf35

    Log Placement – LOGF35 LOGF35 Log Set and Glowing Embers Parts List This illustration shows the rear log positioning bracket and 4 pin locating positions. Log A has 2 locating holes. Position those 2 holes over the 2 pins Log B has 2 locating holes. Position those 2 holes over the 2 pins on the left side of the log mounting pan as shown in the picture on the right side of the log mounting pan as shown in the picture above.
  • Page 31: Log Placement - Logf36

    Log Placement – LOGF36 LOGF36 Log Set includes Glowing Embers, Lava Rock, and Place Log #1 onto rear log holder and center. Vermiculite. Place Log #2 onto left side of Log #1. Place Log #3 onto right side Locate 2 holes on bottoms of Logs #4 and #5, and position onto of Log #1.
  • Page 32: Mqrock1/Mqrsp4 For Idv33/Idv36

    MQROCK1/MQRSP4 for IDV33/IDV36 MQRSP4 Parts List Remove the ember plates and the grate bar by removing the 2 left 1Ea Rock Support and right screws on the grate bar. 1Ea Ember Plates Assembly Reinstall screws after removing parts. Place the MQRSP4 Rock Platform and ember plates into place as Step 1: Place Rocks #4 into position as shown.
  • Page 33 MQROCK1/MQRSP4 for IDV33/IDV36 (continue) Step 4: Place Rocks #6 into position as shown above. Step 5: Place Rocks #3 into position as shown above. Step 6: Place Rocks #1 into position as shown above. Step 7: Place Rocks #3 and #4 into position as shown above.
  • Page 34: Conversion Kit Instructions - Part A

    Conversion Kit Instructions – PART A PLEASE CONFIRM THAT STEP 4 IS UNDERSTOOD BEFORE PROCEEDING WITH CONVERSION. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 35: Gas Conversion For Top Convertible Pilot (Series 019065X) - Part B

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 36: Idv33 Parts List

    Grill Kit – Black IDV36PBL Panel Grill Kit – Black VI30PBL Panel Grill Kit – Black Fireplace Accessories for IDV36 (Both Front Kits) Fireplace Accessories for IDV33 (Both Front Kits) Door Frames Overlays Door Frames Overlays HB36ADTH Arch Door Top Half Black Z33ADDX Arch Door Frame –...
  • Page 37: Parts For Idv33 And Idv36

    2000-P5637 #Spring Extension for Grills Other Accessories 6000-150 #Ceramic Robax Glass Z1MT Thermostat Millivolt Wall Mount (For IDV33 – 27-1/2” x 16”) Z80PT Thermostat Programmable Digital Millivolt Wall 36HB-310 #Ceramic Robax Glass Mount (1F80-40) (For IDV36 – 31-11/16” x 20-7/16”)
  • Page 38: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is light.
  • Page 39 This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed inside the continental United States, Alaska, Hawaii, and Canada. The warranty applies only if the unit is installed and operated in accordance with the printed instructions and in compliance with applicable installation and building codes and good trade practices.

This manual is also suitable for:

Idv36

Table of Contents