Heat of Extraction/Rejection Data - Dual Capacity Units
Model
Part Load
026
Full Load
Part Load
038
Full Load
Part Load
049
Full Load
Part Load
064
Full Load
Part Load
072
Full Load
Note: operation not recommended in shaded areas.
Heat of Extraction (kBtuh)
GPM
30°F
50°F
3.0
13.1
5.0
9.4
13.8
7.0
9.6
14.1
4.0
17.8
6.0
13.4
18.8
8.0
13.6
19.3
4.0
17.9
6.0
12.8
18.7
8.0
13.9
19.7
5.0
25.1
7.0
18.7
26.2
9.0
19.1
26.9
5.0
24.0
8.0
19.2
26.4
11.0
19.8
27.5
6.0
33.3
9.0
26.0
34.7
12.0
26.5
35.7
6.0
31.0
10.0
21.6
31.4
14.0
22.6
32.6
8.0
40.8
12.0
31.9
43.8
16.0
32.2
44.7
10.0
36.4
13.0
25.2
36.7
16.0
26.7
38.2
12.0
48.3
15.0
37.2
51.6
18.0
37.6
52.7
ASTON INDOOR SPLIT SERIES INSTALLATION MANUAL
70°F
90°F
30°F
17.6
21.5
18.6
22.6
21.7
18.9
23.0
21.9
23.4
28.5
24.7
29.9
29.9
25.1
30.5
30.1
23.3
28.1
24.5
29.8
29.8
25.2
29.8
30.3
31..5
36.1
33.2
38.6
41.8
34.3
40.0
42.0
29.5
33.7
32.6
37.5
40.6
34.3
39.9
40.0
40.6
46.1
42.8
49.1
56.0
44.2
50.9
56.1
39.2
46.1
40.9
49.7
52.4
41.7
49.8
52.2
52.7
64.7
55.1
65.8
66.8
56.8
68.6
67.2
46.5
54.7
48.5
59.1
57.7
49.4
59.1
57.3
62.7
69.0
65.4
70.9
73.6
67.5
73.5
74.1
37
Heat of Rejection (kBtuh)
50°F
70°F
90°F
23.5
22.9
21.8
23.6
23.0
21.7
23.7
23.1
21.7
31.0
31.2
30.0
31.1
31.3
29.9
31.2
31.3
29.9
32.5
31.8
30.0
32.7
32.0
30.1
33.1
32.4
30.4
44.8
45.1
42.8
45.2
45.7
43.6
45.5
46.0
43.8
44.9
46.1
44.0
45.0
45.8
43.4
44.9
46.1
44.3
60.2
60.2
56.4
60.2
60.8
57.4
60.4
61.1
57.6
56.3
55.4
52.1
56.2
55.5
52.4
56.2
55.6
52.6
73.7
75.7
70.3
74.1
76.1
70.5
74.5
76.5
70.9
63.4
63.0
58.9
63.2
63.0
59.2
63.2
63.3
59.5
81.8
83.0
77.8
82.1
83.3
78.0
82.6
83.8
78.4
110°F
20.2
20.2
28.1
28.1
28.2
28.5
41.0
41.1
40.5
41.5
52.9
53.2
49.4
49.7
66.2
66.3
55.1
55.4
71.9
72.2