6.
Clean the top surface of the prism.
7.
Put the enclosure cap back on and use the 2 Allen screws to secure it in
place again. Do not over tighten them.
8.
Put the front tube back on.
NOTE:
Dust will not matter beyond this point,
unless it is a stain. To remove a stain, please send it
back to the factory for repair.
BE VOIDED if you perform step 9 and beyond.
9.
Pull the black rubber wedge at the roof of
the prism out with a pair of narrow pliers.
10.
Lift the prism up by using the index finger
and the thumb.
11.
Clean the prism with lens cleaning solu-
tion and put it back.
12.
Put the rubber wedge back.
13.
Put the enclosure cap back and use the 2
allen screws to secure it in place. Do not
over tighten them.
14.
Put the front tube back on.
Letus35 Mini User Guide
The warranty WILL
CAUTION
9