Page 1
HOT FOOD HUMIDITY CABINET MODEL HFD2A-120V/230V HFD3A-120V/230V Installation and Operation Instructions 2M-Z3437 Rev. L 1/17/07 HFD2A 230V ONLY...
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifi cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifi...
Hot Food Humidity Cabinet. Therefore, STAR Manufacturing recommends using distilled water for the prevention of scaling in your equipment. This will prolong the life of your STAR equipment.
6. Temperature and Humidity Control Operation - a. Fahrenheit or Celsius Selection - The control will read cabinet air temperature in F° or C°. To change this indication press and hold the MODE switch and then press + to change the setting. b.
7. Fill reservoir by lifting reservoir lid and pouring water in until both the fi ll and low water light should be "OFF" when the tank is full. HFD-2A holds approximately 3 quarts and HFD-3A holds approximately 5 quarts. Both lights will be off until the water level drops below a specifi ed set level and the low water light comes on.
CLEANING INSTRUCTIONS WARNING DISCONNECT ELECTRICAL CORD BEFORE CLEANING THE CABINET 1. To maintain fi nish and shine of unit, wipe daily with a damp cloth and mild soap. Do not use harsh detergents or scouring pads. 2. Daily cleaning of inside glass, bottom pan and racking system with a damp cloth is required.
TROUBLE SHOOTING GUIDE This guide is recommended for use by a qualifi ed service technician familiar with electrical commercial equipment. 1. Unit does not operate. Be sure unit is plugged into correct supply voltage. Be sure power switch is turned on. Disconnect power cord and check power switch and wiring connections for bad connections.
Page 9
5. Unit turns on, everything works but water heater does not work. Check electronic control on the front of unit. Verify that the humidity setting is set for a value of 10 to check control. Be sure water tank is fi lled with water and the water fi ll light is off. With the unit operating for several minutes the water in the fi...
Page 10
Visit our Website at: www.star-mfg.com Email: service@star-mfg.com THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL This unit has been tested for proper operation before leaving our plant to insure delivery of your unit in perfect condition. However, there are instances in which the unit may be damaged in transit. In the event you discover any type of damage to your product upon receipt, you must immediately contact the transportation company who delivered the item to you and initiate your claim with same.
Page 13
SOME ITEMS ARE INCLUDED FOR ILLUSTRATIVE PURPOSES ONLY AND IN CERTAIN INSTANCES MAY NOT BE AVAILABLE INSTALLATION OF 4 RACKS MODEL: HFD-2 STAR MANUFACTURING INTERNATIONAL INC. THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC. SK1858 Rev - 04/26/2001...
Page 14
This drawing contains information confidential to Star Manufacturing International, Inc. No reproduction or disclosure of its contents is permitted. SOME ITEMS ARE INCLUDED FOR ILLUSTRATIVE PURPOSES ONLY AND IN CERTAIN INSTANCES MAY NOT BE AVAILABLE STAR MANUFACTURING INTERNATIONAL, INC. MODEL: HFD-2A,-3A SK1714 REV.
Page 15
This drawing contains information confidential to Star Manufacturing International, Inc. No reproduction or disclosure of its contents is permitted. SOME ITEMS ARE INCLUDED FOR ILLUSTRATIVE PURPOSES ONLY AND IN STAR MANUFACTURING INTERNATIONAL, INC. CERTAIN INSTANCES MAY NOT BE AVAILABLE MODEL: HFD-2A,-3A 120V/230V SK1375 REV.
PARTS LIST January 17, 2007 Rev. L HFD2A and HFD3A HUMIDIFIED CABINET MODEL Number Part Number Number Description and Model Designation Unit C3-G8021 CORD ASSEMBLY HFD-2A 2E-05-07-0169 CORD ASSEMBLY HFD-3A A4-120165 CORD ASSEMBLY (230V) 2K-Y2968 BUSHING - STRAIN RELIEF 2A-6904...
Page 17
PARTS LIST January 17, 2007 Rev. L HFD2A and HFD3A HUMIDIFIED CABINET MODEL Number Part Number Number Description and Model Designation Unit 2E-Z3287 CONTROL BOARD (120V/230V) 2S-Z3608 BULB - STANDARD 75 WATT (120V) HFD-2A / HFD-3A 2S-Z0630 BULB - STANDARD 100 WATT (230V)
Page 20