  • Page 1 Title: ( BIO-RAD LOGO-B/W) Creator: Twister Barcode Reader Interface Guide P/N 400-0174...
  • Page 3 Laboratories. All rights reserved. Reproduction in whole or part is prohibited. Trademarks The Bio-Rad logo is a registered trademark of Bio-Rad Laboratories. Twister is a trademark of Zymark Corporation. Microsoft is a registered trademark of Microsoft Corporation. Windows is a trademark of Microsoft Corporation. All other trademarks and registered trademarks are of their respective holders.
  • Page 4 These symbols are intended to draw your attention to particularly Table of Symbols important information and alert you to the presence of hazards as indicated. Some of these symbols may not appear in the manual or on the product: DANGER An imminently hazardous situation, which, if not avoided, will result in death or serious injury.
  • Page 5 These symbols are intended to draw your attention to particularly Table of Symbols important information and alert you to the presence of hazards as indicated. Some of these symbols may not appear in the manual or on the product: Hazardous fumes. Hot surface, risk of burns.
  • Page 7: Table Of Contents

    Table of Contents INTRODUCTION .....................1 ..................1 REINSTALLATION EQUIREMENTS Tools Required .......................1 Twister Setup Required ....................1 .......................1 SSEMBLY VERVIEW INSTALLATION ....................3 Installation Warnings ......................3 Installation Notes ......................3 ....................4 NPACK THE NTERFACE ........................4 ARTS ..................5 NSTALL THE ARCODE EADER ............7 NSTALL THE ARCODE EADER NTERFACE...
  • Page 9: Introduction

    Introduction The Twister/Barcode Reader Interface Kit enables the Twister to use a barcode reader to read and record the barcodes on each microplate in the run. The Barcode Reader Interface Kit includes a Symbol barcode reader (which attaches to the Lid Storage Platform) and the software necessary to set the barcode reading options in each run.
  • Page 11: Installation

    Installation Installation Warnings • Turn the Twister power OFF before beginning these WARNING procedures. • Use only the tools listed in this manual to perform the steps described in the instructions. • Never perform any operation on the instrument in an environment where potentially damaging liquids or gases are present.
  • Page 12: Unpack The Interface Kit

    Remove all components from the shipping carton and verify that all parts are included. (See the Parts List below.) If any parts are missing, contact Bio-Rad. See Contact Us at the front of this manual for more information. Retain the shipping carton and packing materials. If the contents should need to be returned for repair, use the original packing materials and shipping carton.
  • Page 13: Install The Barcode Reader

    Installation Install the Barcode Reader The barcode reader attaches to the Lid Storage Platform. The Lid Storage Platform must be installed and configured before installing the barcode reader. See the Twister User's Guide for instructions on installing and configuring the Lid Storage Platform. Tools: Phillips head screwdriver Step Action...
  • Page 14 Twister/Barcode Reader Interface Guide Install the Barcode Reader, Continued Step Action The 25-pin end of the barcode reader communications cable has a socket for the power cable. Plug the power cable into this socket, as shown below. Plug the 25-pin end of the barcode reader cable into the 25-pin end of the adapter cable.
  • Page 15: Install The Barcode Reader Interface Software

    Installation Install the Barcode Reader Interface Software The Barcode Reader Interface software enables the Twister software to communicate with and control the barcode reader. Step Action Turn ON the computer. Start Windows, if it is not already running. Click the Windows Start button to display the Start Menu. Select Settings, and then click on Control Panel to open the Control Panel Folder.
  • Page 16: Start The Twister Software

    Switch ON the Twister. Double-click the Twister V2.0 icon on the Windows desktop. Select the Bio-Rad Twister V2.0 program group from the Windows Start button, then click on Twister V2.0. The Twister software starts, the Twister Splash Screen is displayed, and the software attempts to communicate with the Twister.
  • Page 17: Teach The Barcode Reader Position

    Installation Teach the Barcode Reader Position Before the barcode reader can be used, the Twister must be taught the Barcode Reader Position. The barcodes on your plates should be the same size and in the same location on all the plates. Do not mix plate types or sizes. Step Action From the Twister Main Menu, click the Positional Training button to...
  • Page 18 Twister/Barcode Reader Interface Guide Teach the Barcode Reader Position, Continued Step Action Save the settings and close the Positional Training window. Click the Save Plate Data Button to save the current settings to the plate displayed in the Plate Description textbox. If the plate is the current default, the Twister will be updated automatically.
  • Page 19: Operation With The Ultramark

    Operation with the Ultramark The Barcode Reader, the Twister, and the Ultramark are all operated through Bio-Rad's Microplate Manager software, which is included with the Ultramark. When you perform a plate run, each barcode is scanned and recorded in a plate file in Microplate Manager. See the Microplate Manager User Guide for details.
  • Page 21: Operation With An External Device

    Operation with an External Device This chapter provides general information about operating the Barcode Reader with an external device other than the Ultramark. The Barcode Reader enables the Twister to read the barcode on each microplate and log the decoded barcodes in a log file in a user- specified location.
  • Page 22: Choose The Barcode Parameters

    Twister/Barcode Reader Interface Guide Choose the Barcode Parameters The Barcode Parameters screen is displayed in the Run Configuration window. Use this screen to read the barcode labels on the microplates in the run and record the barcodes in a log file. If barcode reading is not desired in a run, verify the Log Barcodes checkbox is not checked, and click the Next button at the bottom of the screen to display the next screen in the Run Configuration window.
  • Page 23: Glossary

    Glossary Extended Capacity The Twister with the Expansion Kit has a capacity of up to 80 microplates without lids, or up to 60 microplates with lids. Toppers can be used on the microplates without lids. This configuration uses 5 racks (4 Input Racks and one Output Rack). A flat cover placed on top of a microplate to prevent evaporation and/or contamination of the samples in the plate.
  • Page 25: Index

    Index Log Barcodes Checkbox ........10 Log File Path Textbox........10 Append to Existing File Option......10 Assembly Overview ............2 Manual Trigger Cable ........4 Mounting Bracket..........4 Barcode Parameters Choosing ............11 Operation............9 Barcode Parameters Screen......10 Barcode Reader..........