Ericsson DRC-200 Installation Manual

Desktop
Hide thumbs Also See for DRC-200:

Advertisement

Operator's/Installation
Manual
DRC-200
DESKTOP REPEATER

Advertisement

Table of Contents
loading

Summary of Contents for Ericsson DRC-200

  • Page 1 Operator’s/Installation Manual DRC-200 DESKTOP REPEATER...
  • Page 2: Revision History

    Ericsson Inc., at any time and without notice. Such changes will be incorporated into new editions of this manual. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission of Ericsson Inc.
  • Page 3: Table Of Contents

    AE/LZT 123 1899 R1B TABLE OF CONTENTS Page DESCRIPTION ..........INSTALLATION .
  • Page 4: Description

    AE/LZT 123 1899 R1B DESCRIPTION NOTE The DRC-200 is a state-of-the-art Desktop Repeater for In this manual, the words repeater, radio and unit are operation in the Land Mobile UHF (450-470 MHz) fre- used interchangeably. quency band. The repeater operates in the UHF band with a 25 watt (without duplexer connected) RF output.
  • Page 5: Installation

    AE/LZT 123 1899 R1B If used, plug in the External Speaker. This discon- INSTALLATION nects the Unit’s internal speaker. NOTE Install the microphone’s cable in the modular jack It is recommended that the repeater and antenna in- located on the front panel. There will be a click stallations be performed by a technician qualified in when the connector is fully seated.
  • Page 6: Power On/Off Switch

    AE/LZT 123 1899 R1B POWER ON/OFF Switch REMOTE Button Power ON/OFF is a rocker switch. Press in at the top Not used. end to turn the unit ON. Press in at the bottom end of it to turn the radio OFF. REM Indicator The indicator (LED) at the left end of the window (la- Not used.
  • Page 7: Multiple Cg/Dcg Decode

    AE/LZT 123 1899 R1B Continued erated as No. 18, it then cannot also be re-generated as No. Pin No. Purpose/Specification 23 . Discriminator’s Audio Output; buffered unprocessed (not de-emphasized) audio. One of the 16 different tones or codes can be an input from an external encoder.
  • Page 8: Maintenance

    AE/LZT 123 1899 R1B Although no repeater set-up would likely be configured NOTE to accept all 5 PTTs, it is quite possible that at least two of the five would be utilized. For example, the receiver’s PTT For In-Warranty service information, refer to the action and the front panel’s PTT would probably be used Limited Warranty And Repair Information para- during the repeater’s initial installation and its checkout.
  • Page 9: Channel Guard Tones (Ctcss)

    AE/LZT 123 1899 R1B not be used for more than one user. However, the Time-Out Timer – the unit’s Time-Out (carrier con- same encode code could be used for all 16 users if trol) Timer can either be disabled or set to allow a desired.
  • Page 10: Digital Channel Guard Codes

    AE/LZT 123 1899 R1B Digital Channel Guard Codes 104 codes CDCSS codes are specified by a code number in the PC programmer. The following is the relationship between the PC programming code number and the resulting TIA/EIA CDCSS code and its inverted equivalent. Code Inv.
  • Page 11 AE/LZT 123 1899 R1B You may use this form to record the Unit’s configuration. Decode Encode Encode Tone (Hz) Tone (Hz) During Courtesy User Memo or Code or Code Hang Time Beep Notes/Comments Receive Frequency: Transmit Frequency: RF Output Power: (High/Low or record Watts) Beep on Button Press:...
  • Page 12: Limited Warranty

    AE/LZT 123 1899 R1B LIMITED WARRANTY Ericsson Inc. (hereinafter “Seller”) warrants to the original purchaser for use (hereinafter “Buyer”) that the Equipment manufactured by Seller shall be free from defects in material, workmanship and title and shall conform to its published specifications.