Mendota FV-33i Owner's Manual
Mendota FV-33i Owner's Manual

Mendota FV-33i Owner's Manual

Fullview direct vent gas fireplace insert heater

Advertisement

FULLVIEW
F
Do
not store or
r use gasolin
vap
pors and liqu
uids in the vi
oth
her appliance
e.
WH
HAT TO DO IF
YOU SMELL G
Open window
ws.
Do not touch
h electrical sw
Do not try to
o light any app
Extinguish a
any open flame
Do not use t
he phone in y
Immediately
call your gas
phone. Follo
ow the gas su
If you canno
ot reach your g
department.
WARN
If th
he information
n in this manu
fire
e or explosion
may result ca
per
rsonal injury o
or loss of life.
WARN
Do
NOT use this
appliance if an
Imm
mediately call a
a qualified serv
app
pliance and to
replace any p
any
y gas control, w
which has been
In th
he Commonwe
ealth of Massac
Installation m
must be perform
gas fitter;
A CO detecto
or shall be insta
appliance is i
nstalled.
W DIRECT
T VENT G
Mod
HO
ME OWN
D
DOCUMENT
ne or other fl
ammable
icinity of this
s or any
GAS
witches.
pliance.
e.
your building.
supplier from
m a neighbor's
pplier's instru
uctions.
gas supplier, c
call the fire
NING
ual is not follow
wed exactly, a
ausing proper
rty damage,
NING
ny part has bee
en under water
vice technician
n to inspect the
art of the cont
trol system and
n under water.
chusetts:
med by a license
ed plumber or
alled in the room
m where the
GAS FIRE
PLACE IN
del FV-33
3i
NER'S M
MANUAL
NO. FV33i-O
OM-1110
WAR
RNING: Impro
tion,
service or ma
erty
damage. Refe
addi
tional informat
vice
agency or the
A qu
ualified installer
er m
must perform in
s
Do n
not store or use
pors
s and liquids in
plian
nce.
Do n
not operate this
crac
cked or broken
shou
uld do replacem
a
Men
ndota gas firepl
Do n
not burn wood,
plac
ce. This firepla
heat
t source. It is a
mar
ry heat supply.
r.
The
installation mu
e
the a
absence of loc
d
Fuel
l Gas Code, A
Gas
and Propane
THE
ESE INSTRUC
THE
E HOMEOWNE
NSERT H
EATER
L
oper installatio
on, adjustment,
aintenance can
n cause injury o
er to this manu
ual. For assist
tion consult a q
qualified instal
gas supplier.
FO
OR YOUR SAF
FETY
r, service agen
ncy, or the gas
stallation and s
service.
e gasoline or ot
ther flammable
the vicinity of t
this or any othe
WARNING
G
s appliance wit
h the glass rem
. A licensed or
r qualified pers
ment of glass.
WARNING
G
aces are heat
producing app
paper or othe
r materials in th
ce is designed
as a suppleme
advisable to hav
ve an alternativ
ust conform w
with local codes
cal codes, with
h the current N
ANSI Z223.1, o
or the current N
Installation Cod
de, CSA B149.
CAUTION
CTIONS ARE
TO REMAIN
ER.
, altera-
or prop-
tance or
ler, ser-
suppli-
e va-
er ap-
moved,
son
liances.
his fire-
ent
ve pri-
s or, in
National
Natural
.1
WITH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FV-33i and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mendota FV-33i

  • Page 1 FULLVIEW W DIRECT T VENT G GAS FIRE PLACE IN NSERT H EATER del FV-33 ME OWN NER’S M MANUAL DOCUMENT NO. FV33i-O OM-1110 not store or r use gasolin ne or other fl ammable RNING: Impro oper installatio on, adjustment, , altera- tion, service or ma...
  • Page 2: Table Of Contents

    FV33I DOOR REMOVAL AND INSTALLATION .................. 9   BLOWER SYSTEM INFORMATION ....................12     BLOWER OPERATION ................................12 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM ........ 13   MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY ......15   P a g e 85-03-00811...
  • Page 3: Safety And Warning Information

    SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instruc- tions may result in a possible fire hazard and will void the warranty. Any safety screen or guard removed for servicing must be replaced before operating this appliance. DO NOT USE this appliance if any part has been under water.
  • Page 4: Specifications

    SPECIF FICATION NS MODE EL FV-33i tural Gas Propane Gas Input t rating (Btu/h hr) 0-610 m 31,000 31,000 Minim mum input (Bt tu/hr) 0-610 m 10,000 13,000 Orific ce size (DMS ) 0-610 m (fr ront/rear) 49/45 ”/ ”...
  • Page 5: Congratulations

    Fireplace and replace any part of the control system and any gas control, which has been under water. DO NOT use this fireplace if the burner does not light immediately. Turn unit off and call Mendota ap- proved service person if there is any delay in burner light off.
  • Page 6: Before You Begin

    FORE YO OU BEGIN Read this entire ma anual before yo ou use your new w fireplace (es specially the se ection “Safety Precautions” o on page 2). Fa ailure to follow the in nstructions may y result in prop perty damage, b bodily injury, o or even death.
  • Page 7: Remote Transmitter Operating Instructions

    . A single “be eep” will con nfirm receptio on of the comm mand. t): This functio on controls th he Mendota A Accent Light f unction. Aux ( (Accent-Light Press ing the UP ke ey in this mod de will TURN...
  • Page 8: Manual Bypass Of The Remote System

    ANUAL BY YPASS O OF THE RE EMOTE S SYSTEM If the e remote tran smitter is mis splaced or los st, the applian nce can be tur rned on manu ually by slidin g the three e position slide er switch on t the receiver to o the ON pos...
  • Page 9: First Time" Pilot Lighting Instructions

    “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed! CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot. 1.
  • Page 10: Initializing The Remote Control System

    ON as long as the “Stand- ing Pilot Light Switch” is in the ON position. NOTE: Mendota Fireplaces recommends that the Standing Pilot Mode be used during the winter months when external temperatures fall be- low 50 F.
  • Page 11 DOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Glass latch tool #HA-57-00743 is supplied with the unit. To Unlatch Glass Frame Latches: 1.) INSERT 1.
  • Page 12: Blower System Information

    Connect only to a LIVE outlet that is not controlled by any other switching device. Dual blowers are provided as standard equipment with this FV-33i Insert. The dual blowers have an air output rating of 210 CFM (in free air). This Insert is designed to operate with the blowers turned OFF or ON. Turning the blower on increases the overall efficiency of this fireplace and aids in distributing and circulating heat to the room this Insert is installed in.
  • Page 13: Mendota Warranty Qualification & Service Reference Form

    As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is im- portant as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and quali- fies the owner for Mendota's lifetime limited warranty.
  • Page 14 TAPE SHUT -------------------------------------------------------------------------------------------------------------------------------------------------------- POSTAGE NEEDED JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N.W. CEDAR RAPIDS, IA 52405 14 | P a g e 85-03-00811...
  • Page 15: Mendota Extended Lifetime Protection And Limited Warranty

    The use of unauthorized components will make this warranty null and void. This warranty shall be effective only if the original purchaser of the Mendota appliance is registered with Mendota Division within thirty (30) days of the date of purchase. Such registration or the failure to register shall not be deemed to create any obligation or liability by the manufacturer and this warranty with its conditions and limitations shall be the only procedure for obtaining any rights against the manufacturer and expresses the sole obligation and re- sponsibilities of the manufacturer which are offered to the original purchaser and accepted upon purchase of the appliance.
  • Page 16 Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: www.johnsongas.com www.mendotahearth.com...

Table of Contents