Download Print this page

Marco Traditional A41MTR Installing & Operating Manual page 17

Architect's 41" masonry fireplaces

Advertisement

TEST FOR GAS
LEAKS
1
All gas piping and connections must be tested for
leaks after the installation is completed. Be sure
gas
valve is turned on. Apply soap suds solution
to
all connections and joints.
If
bubbles appear,
leaks can be detected and corrected.
00 NOT
use a match or open flame of any kind to test for
leaks.
Never operate any appliance
with
leaky
connections.
CAUTION:
1) MAKE
SURE THE DAMPER tN YOUR FIREPLACE
IS SET IN A PERMANENTLY OPEN POSITION IN
CASE THE GAS VALVE IS TURNED ON BY ACCI-
DENT, BY FOLLOWING THIS SIMPLE INSTRUC-
TION, YOU WILL PREVENT GAS FROM ESCAP-
ING INTO YOUR LlVtNG
ROOM
AND CAUSING
POSSIBLE SERIOUS INJURIES OR DAMAGE TO
YOUR DWELLING.
2)
TURN ON GAS VALVE.
3) LIGHT LOG LIGHTER WlTH A MATCH.
USE
COMMON SENSE IN LIGHTING.
FOR YOUR
SAFETY, NEVER USE 0 8 STORE GASOLINE OR
OTHER FLAMMABLE LIQUIDS IN THlS OR ANY
OTHER APPLIANCE.
4)
AFTER YOUR LOG HAS STARTED TO BURN,
TURN
OFF
GAS VALVE.
THE
KEY USED FOR
TURNING THE GAS VALVE ONlOFF SHOULD BE
KEPT OUT OF REACH OF CHILDREN.
5) TO RESTART, REPEAT RELIGHTING INSTRUC-
TIONS.
6)
KEEP
ORIFICES CLEAN FROM ASHES AND
DEBRIS. THlS WlLL PREVENT THE ORIFICES
FROM BECOMING CLOGGED. CLEAN IT ONLY
WHEN COLD.
NEVER ALLOW GAS TO RUN UNLIGHTED. IF THlS
HAPPENS, THERE IS A POSSIBILITY OF GAS ES-
CAPING INTO YOUR LIVING AREA. IF YOU SMELL
GAS, OPEN WINDOWS, EXTINGUISH ANY OPEN
FLAME AND IMMEDIATELY CALL YOUR LOCAL GAS
SUPPLIER. NEVER LEAVE CHILDREN ALONE NEAR
THE APPLIANCE WHEN IN USE.
REFER TO IN-
STRUCTION MANUAL FOR OTHER INSTRUCTION
DETAILS.
KEEP THESE INSTRUCTIONS FOR FUTURE
REF-
ERENCE.
COLD
CLIMATE INSTALLATION
If you live in
a cold climate,
it is
especially important to
seal all cracks around fireplace with non-combustible
material and wherever cold air could enter
the
room.
Surround material
must
be caulked
where it meets
the
black metal facing of the fireplace to avoid cold air
intrusion. Use only non-combustible caulking material
on fireplace facing to seal.
In areas of extreme cold, it
is
recommended that
the
outer wall of the chase
be
insulated. This will reduce
the
possibility of cold air convection currents
on
the fire-
place. NEVER use blown-in
type of
insulation
as this
could
plug the holes at the base of the unit and interlere
with
the thermal syphoning action necessary to
keep
the
chimney cool.
FINISHING THE
FIREPLACE
FIREPLACE FACING
When selecting the finish material for
your
fireplace,
it
is
important to remember the following:
THE BLACK
FACE OF THE FIREPLACE MUST NOT BE COVERED
WlTH ANY TYPE OF COMBUSTIBLE MATERIAL.
Non-combustible facing material
such as
tile, brick,
glass, etc. may overlap the black face of the fireplace.
Be sure to use non-combustible heat resistant mortar or
adhesive when attaching to fireplace face. The face of
the fireplace may be painted
to
match the mom decor
provided you use a heat resistant paint.
NOTE: DECORATIVE FACING MUST NOT EXTEND
INTO THE FIREPLACE OPENING AT ALL, BECAUSE
IT WlLL INTERFERE WlTH
THE
OPERATION OF THE
GLASS DOORS. THE GLASS DOOR MOUNTS OVER
M E FACING MATERIAL. THE MOUNTING HARD-
WARE PROVIDED WILL ALLOW INSTALLATION TO
FACING MATERIAL OF
O"
TO 5 IN
WIDTH.