Summary of Contents for Ritter Camplifier 360
Page 1
& BlueAmps Users MANUAL Camplifier 360 2 x80W stereo add on power amplifier module for the Kemper Profiling Amplifier input & BlueAmps CAMPLIFIER 360 Power 230VAC/50Hz/420VA left right / mono Fuse speaker Risk of electric shock! Do not operate outside of KPA enclosure! Equipment must be earthed.
- download the latest version of the user manual from the Internet 1 INTRODUCTION Thank you for having chosen a CAMPLIFIER 360 add on amplifier module. If you follow the instruc- tions given in this manual, we can assure you that you will enjoy this device for many years.
Page 4
English Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C connection cable or on the casing, do not take the device into operation and immediately consult your local dealer. This device falls under protection-class I. The power plug must only be plugged into a protection class I outlet.
Page 5
Never connect output to output. Before the device is switched on all faders and volume controls have to be set to “0” or “min” position. Never connect the Speaker OUT of the CAMPLIFIER 360 to the signal OUT of the Kemper Profil- ing Amplifier!!
This is why the entrepreneur has to set up warning signs and provide hearing protectors. The staff has to use these. Please note: Tilman Ritter / RITTER Amplification / Marco Wendel / BlueAmps and KPA-Solutions cannot be made liable for damages caused by incorrect installations and excessive noise levels! Page 6 www.kpa-solutions.com...
Page 7
English 3.1 Information on hearing loss More and more young people suffer from hearing loss of 25 decibel or more, mainly caused by loud music from portable music players, discotheques, rock conocerts or band rehersals. Everybody operating amplification systems should know to what sound pressure levels he exposes his or the audience’s hearing.
English 4 OPERATING DETERMINATIONS The CAMPLIFIER 360 add on amplifier module has been specially designed for the operation mounted INSIDE of the Kemper Profiling Amplifier (KPA). Any operation of the CAMPLIFIER 360 outside of the KPA is forbidden! The CAMPLIFIER 360 may be used to provide power amplification to speaker cabinets. The signal source must be the Kemper Profiling Amplifier (KPA).
English The ambient temperature must always be between -5° C and +45° C. Keep away from direct insula- tion (particularly in cars) and heaters. The relative humidity must not exceed 50 % with an ambient temperature of 45° C. This device must only be operated in an altitude between -20 and 2000 m over NN. The ambient contamination must never exceed level and must not be conducting, only dry.
English 5.2 Operating elements and connections input & BlueAmps CAMPLIFIER 360 Power 230VAC/50Hz/420VA left right / mono Fuse speaker Risk of electric shock! Do not operate outside of KPA enclosure! Equipment must be earthed. Do not expose to rain or moisture! 8 Ω...
Page 11
039 Dresden Tel. : 035 60 5 982 info@kpa-solutions.com Please do NEVER connect the power cord to the CAMPLIFIER 360 when the unit has not been as- sembled into the Kemper Profiling Amplifier correctly! 6.1 Preparation prior Installation Check the upper chamber at the back side of the Kemper Profiling Amplifier (KPA) for objects such as cables, paper, guitar picks, guitar strings etcetera.
Page 12
Remove all 8 screws that surround the KPAs back chamber. You will need a TORX 0 screw- driver to do that. Additionally to the power cord that has been delivered with your CAMPLIFIER 360, 8 small screws have been delivered with it too.
It might be helpful to put the KPA carefully on its operation side for this. Please make sure the CAMPLIFIER can be inserted smoothly and without any tension. Align the 8 mounting holes of the CAMPLIFIER 360 as good as possible to the threaded holes at the back sheet metal of the KPA.
English 7 CONNECTIONS All connections have to be made or changed only if the amplifier is switched off! 7.1 Inputs Connect the output of the KPA to one of the jacks to the Camplifiers INPUT sockets. The input signal should have line level. Information on installing speaker cables Input cables should be short and direct, since high frequencies will mostly be absorbed if the ca- bles are unnecessarily long.
Page 15
English 7.2 Speaker outputs In stereo mode, the amplifier can operate two speakers or two speaker groups. For connecting speakers, Speaker jacks are provided. When using the Speaker jacks, turn each plug to the right until it locks into place. For unlocking, pull the unlock button and turn the plug to the left. •...
Page 16
• Never wind up cables tightly around the elbow, but rather sleek with an interior diameter of 20 to 30 7.2.1 Stereo Operation The most frequently used operating mode of the Camplifier 360 might be stereo operation, where both channels are operated independent of each other. The highest output power during stereo operation is achieved by connecting 8 ohms speakers.
Page 17
(marked yellow at the connection scheme at the Camplifier). The highest output power during stereo operation is achieved by connecting 8 ohms speakers. With 6 ohms speakers the output power will be slightly reduced. input & BlueAmps CAMPLIFIER 360 Power 230VAC/50Hz/420VA left right / mono...
Page 18
Doing so will ensure the idle mode of the right channel. The highest output power during stereo operation is achieved by connecting 8 ohms speakers. With 6 ohms speakers the output power will be slightly reduced. input & BlueAmps CAMPLIFIER 360 Power 230VAC/50Hz/420VA left right / mono...
English 7.3 Connection with the mains Finally connect the device to the mains with the supplied mains cable. The occupation of the con- nection cables is as follows: brown wire - life wire - L blue wire - neutral - N yellow/green wire - protective earth The earth has to be connected! If the device will be directly connected with the local power supply net- work, a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the...
English Additional information on the operation When operating the amplifying system, please make sure that the loudspeakers always sound well. When distortions can be heard, either the amplifier or the loudspeaker is overloaded. Overloads can quickly lead to amplifier or speaker damage. In order to avoid damage, please reduce the volume imme- diately when distortions can be heard.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply cable available at your dealer. Should you have further questions, please contact us or your dealer. Contact information: Tilman Ritter RITTER Amplification Veteranenstrasse 3 039 Dresden Tel.
English Power supply 230 V AC, 50 Hz ~ Power consumption 420W max. Audio power output RMS at 2 x 8 ohms 2 x 78W Frequency range 25Hz – 25kHz +/- 0.5dB Damping factor >350 Distortion factor THD % bei max. RMS Leistung Noise voltage <40uVrms unweighted Channel separation...