RHOSS H50246 Installation Manual

RHOSS H50246 Installation Manual

Cassette split air-conditioners
Table of Contents

Advertisement

Available languages

Available languages

ALENIA: 18 - 24 - 36 - 48
Climatizzatori split cassette
Cassette split air-conditioners
Climatiseurs split cassette
Cassette Split-Klimageräte
Climatizadores split cassette
H50246
0.
I-GB
ed.
MANUALE D'INSTALLAZIONE
INSTALLATION MANUAL
MANUEL D'INSTALLATION
MONTAGE-ANLEITUNGS-ANLEITUNG
MANUAL DE INSTALACION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H50246 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RHOSS H50246

  • Page 1 MANUALE D’INSTALLAZIONE INSTALLATION MANUAL MANUEL D’INSTALLATION MONTAGE-ANLEITUNGS-ANLEITUNG MANUAL DE INSTALACION ALENIA: 18 - 24 - 36 - 48 ➔ Climatizzatori split cassette ➔ Cassette split air-conditioners Climatiseurs split cassette Cassette Split-Klimageräte Climatizadores split cassette H50246 I-GB...
  • Page 2 DICHIARAZIONE DI CONFORMITÀ La società RHOSS SPA con sede in Pordenone, Viale Aquileia, 75 dichiara sotto la propria responsabilità che i prodotti della serie “ALENIA” sono conformi alle seguenti direttive: – Compatibilità Elettromagnetica 89/336 CEE e successiva integrazione 92/31 CEE –...
  • Page 3: Indoor And Outdoor Units

    INSTALLATION MANUAL cassette-type air conditioners 18000 - 24000 - 36000 - 48000 BTU/h · FOR THE AIR CONDITIONER TO OPERATE CORRECTLY, IT SHOULD BE INSTALLED ACCORDING TO THE INSTRUCTION GIVEN IN THIS MANUAL. · REMOVAL OF AN CASSETTE-TYPE AIR CONDITIONER AFTER IT HAS BEEN INSTALLED IS AN OPERATION WHICH REQUIRES SPECIAL TRAINING: IF THIS IS NECESSARY, PLEASE CONSULT YOUR DEALER.
  • Page 4: Selection Of Location For Installation

    SELECTION OF LOCATION FOR INSTALLATION INDOOR UNIT min. · The installation of the indoor unit must be carried out on a solid and vibration-free wall. 100cm · There should be no obstruction of the air flow into and out of the unit and the air should be evenly distributed around the whole of the room.
  • Page 5: Installation Of Indoor Unit

    INSTALLATION OF INDOOR UNIT Select an installation place so that there is a clearance of at least 100 cm around the appliance (see fig.1). Make sure that the installation does not interfere with the existent electric wiring or plumbing. Establish the position and size of the hole in the ceiling using the external diameter of the cardboard mounting template (fig.2). Select the final position of the indoor unit in the ceiling using the references “A-B-C-D”...
  • Page 6: Preparation Of Piping

    DRAINAGE OF THE INDOOR UNIT CONDENSED WATER CORRECT DRAINAGE OF CONDENSED WATER FROM THE INDOOR UNIT IS ESSENTIAL FOR SUCCESSFUL INSTALLATION. Examples are given below which show how to correctly carry out the connection of the condensed water drain CORRECT INSTALLATION INCORRECT INSTALLATION The piping has not been The piping has been correctly...
  • Page 7: Piping Connection

    PIPING CONNECTION CAUTION: ONLY use copper pipes for ACR type air conditioners. CONNECTING THE PIPES · Do not remove the cap from the pipes until just before connecting them. This is to prevent humidity or dirt from entering the pipes. ·...
  • Page 8: Electrical Connections

    DUCT-TYPE USE air delivery for outlet through air delivery for outlet through The indoor unit of the cassette-type model allows the appliance to be used as a duct- type model thanks to the purpose-made ope- nings shown in the figure. This method of installation can be very use- ful if you wish to air condition several rooms air delivery for...
  • Page 9 WIRING DIAGRAM : 36000 - 48000 BTU/h COOL ONLY VERSION OUTDOOR UNIT INDOOR UNIT WIRING DIAGRAM : 18000 - 24000 BTU/h HEAT PUMP VERSION OUTDOOR UNIT INDOOR UNIT...
  • Page 10: Final Stages

    WIRING DIAGRAM 36000 - 48000 BTU/h HEAT PUMP VERSION OUTDOOR UNIT INDOOR UNIT FINAL STAGES 1.Wrap some insulating material around the joints of Insulating material the indoor unit and fasten it with insulation tape. 2.Fix the surplus part of the signal cable to the piping or to the outdoor unit.
  • Page 11: Manuale Di Installazione

    MANUALE DI INSTALLAZIONE climatizzatori a cassetta 18000 - 24000 - 36000 - 48000 BTU/h · AFFINCHÉ POSSA FUNZIONARE CORRETTAMENTE, IL CLIMATIZZATORE VA INSTALLATO COME DESCRITTO IN QUESTO MANUALE. · RIMUOVERE UN CLIMATIZZATORE A CASSETTA DOPO CHE É STATO INSTALLATO, É UN’OPERAZIONE CHE RICHIEDE UNA SPECIFICA PREPARAZIONE: NEL CASO SIA NECESSARIO CONSULTATE IL VOSTRO RIVENDITORE.
  • Page 12: Scelta Del Luogo Per L'installazione

    SCELTA DEL LUOGO PER L’INSTALLAZIONE UNITA’ INTERNA min. · Installare l’unità interna su di un muro solido, non soggetto a vibrazioni. 100cm · Le aperture di ripresa e di mandata dell’aria non devono essere ostruite; l’aria deve poter circolare liberamente in tutto l’ambiente. ·...
  • Page 13: Installazione Dell'unità Interna

    INSTALLAZIONE DELL’UNITÀ INTERNA Scegliere un luogo per l’installazione in maniera tale che attorno alla macchina, vi siano spazi di almeno 100 cm (vedi fig.1). Verificare che l’installazione non interferisca con l’impianto elettrico o idraulico già esistente. Determinare la posizione e la dimensione del foro sul soffitto utilizzando il diametro esterno della dima di cartone (fig.2). Scegliere la posizione finale dell’unità...
  • Page 14: Scarico Della Condensa Dell'unità Interna

    SCARICO DELLA CONDENSA DELL’UNITÀ INTERNA LO SCARICO DELLA CONDENSA DELL’UNITÀ INTERNA E UN PUNTO FONDAMENTALE PER LA BUONA RIUSCITA DELL’INSTALLAZIONE. Di seguito, sono riportati schematicamente alcuni esempi di come eseguire correttamente il collegamento per lo scarico della condensa INSTALLAZIONI CORRETTE INSTALLAZIONI ERRATE I tubi non sono stati corretta- I tubi sono stati correttamente...
  • Page 15: Collegamento Delle Tubazioni

    COLLEGAMENTO DELLE TUBAZIONI ATTENZIONE: utilizzare SOLAMENTE tubi di rame per condizionatori di tipo ACR Come collegare i tubi · Rimuovere la chiusura dei tubi solo appena prima di effettuare il collegamento: si deve assolutamente evitare che entri umidità o sporcizia. ·...
  • Page 16: Collegamenti Elettrici

    UTILIZZO CANALIZZATO mandata aria da canalizzare mandata aria da canalizzare L’unità interna del modello a cassetta per- mette, grazie alle apposite aperture mostrate in figura, l’utilizzo della macchina come un modello canalizzato. Questa modalità di installazione può essere molto utile nel caso si volessero climatizzare più...
  • Page 17 SCHEMA ELETTRICO 36000 - 48000 BTU/h VERSIONE SOLO FREDDO UNITÀ ESTERNA UNITÀ INTERNA SCHEMA ELETTRICO 18000 - 24000 BTU/h VERSIONE POMPA DI CALORE UNITÀ ESTERNA UNITÀ INTERNA...
  • Page 18: Fasi Conclusive

    SCHEMA ELETTRICO 36000 - 48000 BTU/h VERSIONE POMPA DI CALORE UNITÀ ESTERNA UNITÀ INTERNA FASI CONCLUSIVE 1. Avvolgere un po’ di isolante termico attorno alle giun isolante termico zioni dell’unità interna e fissarlo con del nastro isolante. 2. Fissare la parte eccedente del cavo dei segnali alle tubazioni o all’unità...
  • Page 19 NOTE...
  • Page 20 RHOSS S.P.A. Via Oltre Ferrovia - 33033 Codroipo (UD) - tel. 0432.911611 - fax 0432.911600 - rhoss@rhoss.it - www.rhoss.it - www.rhoss.com RHOSS Iberica s.l. C/ Leonardo da Vinci, 4 - Pol. Ind. Camí Ral - 08850 Gavà (Barcelona) - telf. ++34-93-6334733 - fax ++34-93-6334734 IR GROUP S.a.r.l.

Table of Contents