Specifications
Voltage
Wire Gauge
Input
Internal Fuses
Input Fuse Rating
Continuous
Surge
Receptacles
Output
Waveform
Voltage Range
Frequency
Page 2
12 VDC Nominal
(11-15 VDC)
5 AWG (up to 6 ft.)
3 AWG (up to 10 ft.)
30 A x 6
180 A
1500
3000
2 AC outlets,
2 USB ports
Modified Sine Wave
120 ±12 V~
60 ±1 Hz
WARNING SYMBOLS AND DEFINITIONS
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided,
Indicates a hazardous situation which, if not avoided,
Indicates a hazardous situation which, if not avoided,
Addresses practices not related to personal injury.
For technical questions, please call 1-800-444-3353.
Ground Wire Gauge
No Load Current
(Switch on)
Maximum efficiency
Full load efficiency
Over voltage Shutdown
Low voltage alarm
Low voltage shutdown
Thermal Shutdown
Note: Battery charge level, wire length and
other factors will effect performance.
will result in death or serious injury.
could result in death or serious injury.
could result in minor or moderate injury.
8 AWG
2 A
90%
85%
15 ±0.5 V
10.5 ±0.3 V
10 ±0.5 V
149 ±9 °F
Item 60601