Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
U S E R ' S M A N U A L V X I 1 6 / 4 8 - C H A N N E L S W I T C H I N G M O D U L E M O D E L V X 4 1 4 C Manual Part No: 11027684...
Page 3
COPYRIGHT C&H Technologies, Inc. (C&H) provides this manual "as is" without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. C&H may make improvements and/or changes in the product(s) and/or program(s) described in this manual at any time and without notice.
Page 4
VME/VXI MODULE WARRANTY C&H Technologies, Inc. warrants its VME/VXI products to be free from defects in material and workmanship for three years from date of shipment. C&H will repair or replace the defective product without charge within the warranty period, provided the defective item is shipped, freight prepaid, to C&H Technologies, at 15809 Vision Drive, Pflugerville, TX 78660.
Page 5
AMENDMENT NOTICE C&H Technologies, Inc. makes every attempt to provide up-to-date manuals with the associated equipment. Occasionally, changes are made to the equipment wherein it is necessary to provide amendments to the manual. If any amendments are provided for this manual they are printed on colored paper and will be provided with the module and manual.
Page 6
This manual describes the operation and use of the C&H Model VX414C VXI 16/48-Channel Switching Module (Part Number 11027680). This VXI module is one of a number of test and data acquisition/control modules in the VME and VXI format provided by C&H.
1.0 GENERAL DESCRIPTION The VX414C 16/48-Channel Switching Module is a C size, Register based switching card that provides 16 channels of SPST (Form-A) switching and 48 channels of SPDT (Form-C) switching. The 16 Form-A channels are rated for up to 5 amps and the 48 Form-C channels are rated for up to 2 amps.
2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION In most cases the VX414C is individually sealed and packaged for shipment. Verify that there has been no damage to the shipping container. If damage exists then the container should be retained as it will provide evidence of carrier caused problems. Such problems should be reported to the carrier immediately as well as to C&H.
Figure 1. Functional Block Diagram 3.1.1 VXI Interface The VXI interface, consisting of the VXI connectors, address decode logic, control logic and data buffer, provides the electrical and mechanical connections to the VXI backplane. It performs address decoding and bus buffering functions.
3.1.3 Relay Driver The relay driver function receives relay control data from the data latch and provides relay coil current control for energizing or de-energizing the relay. A logic high on the input of the relay driver results in a low on its output, thus providing a current through the relay coil, which closes the contact.
3.2 HARDWARE CONFIGURATION Logical Address The logical address has a range of 0 to 255. Any value, except 0 and 255 which are reserved for slot 0 controllers and dynamic addressing, is valid. However, care should be taken not to set the logical address the same as another module in the system. The most significant bit (MSB) has a weighted value of 128 when the switch is in the off (1) position.
AAAA AAAA AAAA AAAA 3.4.2 Rear Connectors The P1 and P2 connectors are configured in accordance with the VXI specification (See Appendix B). Figure 3. Front Panel Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
3.5 CONFIGURATION REGISTERS There are several registers used to configure and control the VX414C. These registers are divided into two groups: VXI Configuration and Relay Control/Status. All of the registers are located within the A16 address space as shown in Table I. The base address of the registers is a function of the Logical Address of the module.
Manuf. ID Manufacturer Identification (C&H Technologies = FC1 VXI Device Type Read Model Code Only ð Model Code Model code (VX414C = FFFE VXI Status/Control Write Not Used Read AAA MID RDY PASS ð A24/A32 Access (0 = disabled) ð...
3.5.2 Relay Control/Status Registers The Relay Control and Status Registers are used for the control and status of relay switch states, as described below. Relay Control/Status Register K15-K0 (10 ) A write to this register controls the state of the Form-A relays K0 through K15 (0 = open, 1 = close).
4.0 OPERATING INSTRUCTIONS All registers and memory, including the flag bytes are accessed as 16-bit data words on even boundaries. The configuration registers are accessed in the A16 address space. The A16 base address is a function of the logical address of the module. It can be computed as follows: ×...
Page 32
READER'S COMMENT FORM Your comments assist us in improving the usefulness of C&H's publications; they are an important part of the inputs used for revision. C&H Technologies, Inc. may use and distribute any of the information that you supply in any way that it believes to be appropriate without incurring any obligation whatsoever.
Page 33
INSTRUCTIONS In its continuing effort to improve documentation, C&H Technologies, Inc. provides this form for use in submitting any comments or suggestions that the user may have. This form may be detached, folded along the lines indicated, taped along the loose edge (DO NOT STAPLE), and mailed.
Page 35
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the VX414C and is the answer not in the manual?
Questions and answers