SAFETY SECTION
Safety signal words are used to designate a degree or
level of seriousness associated with a particular haz-
ard. The signal words for safety markings are WARN-
ING and CAUTION.
a. WARNING indicates a potentially hazardous situa-
tion which, if not avoided, could result in death or
serious injury.
b. CAUTION indicates a potentially hazardous situa-
tion which, if not avoided, may result in minor or
moderate injury. It is also used to alert against
unsafe practices and hazards involving only prop-
erty damage.
▲ ▲
WARNING
!
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do NOT store or use gasoline or other flammable
vapors and liquids or combustible materials in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier,
call the fire department.
— DO NOT RELY ON SMELL ALONE TO DETECT
LEAKS. DUE TO VARIOUS FACTORS, YOU MAY
NOT BE ABLE TO SMELL FUEL GASES.
• U.L. recognized fuel gas and CO detectors are
recommended in all applications, and their
installation should be in accordance with the
manufacturer's recommendations and/or local
laws, rules, regulations, or customs.
— Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
User's Information Guide
Condensing Gas Furnaces
Fan Assisted Combustion System
Upfl ow/ Horizontal and Downfl ow/ Horizontal
Available in French Canadian (FC)
Contents
Safety Section
General Information
To Start the Furnace
Proper Maintenance
The Problem Solver
Regular Dealer Maintenance
Warranty
WARNING
!
EXPLOSION HAZARD
DO NOT USE THIS UNIT IF ANY PART HAS BEEN UN-
DER WATER. A FLOOD DAMAGED UNIT IS EXTREME-
LY DANGEROUS. ATTEMPTS TO USE THE FURNACE
CAN RESULT IN FIRE OR EXPLOSION. A QUALIFIED
SERVICE AGENCY SHOULD BE CONTACTED TO IN-
SPECT THE FURNACE AND TO REPLACE ALL GAS
CONTROLS, CONTROL SYSTEM PARTS, ELECTRICAL
PARTS THAT HAVE BEEN WET OR THE FURNACE IF
DEEMED NECESSARY.
FAILURE TO FOLLOW THIS WARNING COULD RESULT
IN PROPERTY DAMAGE, PERSONAL INJURY OR
DEATH.
WARNING
!
EXPLOSION HAZARD
IN THE EVENT THAT ELECTRICAL, FUEL OR MECHANI-
CAL FAILURES OCCUR, THE OWNER SHOULD IMME-
DIATELY TURN OFF THE GAS SUPPLY AT THE MANU-
AL GAS SHUT OFF VALVE LOCATED ON THE SUPPLY
GAS PIPING COMING INTO THE FURNACE, TURN OFF
THE ELECTRICAL POWER TO THE FURNACE, AND
CONTACT SERVICER.
FAILURE TO FOLLOW THIS WARNING COULD RE-
SULT IN PROPERTY DAMAGE, PERSONAL INJURY OR
DEATH.
32- 5035- 08
1
3
4
6
8
9
11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Condensing Gas Furnaces and is the answer not in the manual?

Questions and answers

Summary of Contents for Residential Systems Condensing Gas Furnaces

  • Page 1 32- 5035- 08 Available in French Canadian (FC) User’s Information Guide Condensing Gas Furnaces Fan Assisted Combustion System Upfl ow/ Horizontal and Downfl ow/ Horizontal IMPORTANT: Users MUST read all instructions in the manual. All manuals MUST be kept for future reference.
  • Page 2 User’s Information ▲ ▲ WARNING WARNING SAFETY HAZARD EXPLOSION HAZARD IMPROPER INSTALLATION, ADJUSTMENT, ALTERA- SHOULD OVERHEATING OCCUR, OR THE GAS SUP- TION, SERVICE OR MAINTENANCE CAN CAUSE PLY FAIL TO SHUT OFF, SHUT OFF THE MANUAL GAS INJURY OR PROPERTY DAMAGE. FOR ASSISTANCE VALVE TO THE FURNACE BEFORE SHUTTING OFF THE OR ADDITIONAL INFORMATION CONSULT A QUALI- ELECTRICAL SUPPLY.
  • Page 3 User’s Information IMPORTANT FACTS ▲ WARNING The fl ow of combustion and ventilating air must not ELECTRIC SHOCK HAZARD be obstructed from reaching the furnace. Air openings THESE SERVICING INSTRUCTIONS ARE FOR USE provided in the casing of the furnace must be kept free BY QUALIFIED PERSONNEL ONLY.
  • Page 4: To Start The Furnace

    User’s Information To Start the Furnace Lighting instructions. 5. Turn the external main gas shutoff valve and the Your furnace does not use a continuously burning pilot toggle switch located on the main gas valve inside fl ame. Therefore, manually lighting your furnace is not the unit to the “ON”...
  • Page 5 User’s Information NOTE THE LOCATION OF THE MANUAL MAIN GAS SHUTOFF VALVE FOR YOUR FURNACE. Have your installer or servicer show you the location if you have any questions. UPFLOW FURNACE Manual Main Gas Shut-off Valve May Be Located on the Left or Right Side HORIZONTAL FURNACE Manual Main Gas Shut-off Valve May Be Located on the Top or Bottom Side MAIN MANUAL SHUTOFF...
  • Page 6: Proper Maintenance

    User’s Information Proper Maintenance AIR FILTERS return air inlet. The fi lter may be secured with fi lter NOTE: Filters are NOT included with all Furnaces, how- retaining brackets (as shown) or a fi lter rack. ever; the Furnace should never be run without a fi lter. To clean or replace fi...
  • Page 7 User’s Information REQUIRED FILTERS - BOTTOM CABINET WIDTH FILTER QUANTITY & SIZE 17-1/2" 1 - 17" X 25" X 1" 21" 1 - 20" X 25" X 1" 24-1/2" 1 - 24" X 25" X 1" REQUIRED FILTERS - SIDE ** CABINET WIDTH FILTER QUANTITY &...
  • Page 8: The Problem Solver

    User’s Information REQUIRED FILTERS - DOWNFLOW CABINET WIDTH FILTER QUANTITY & SIZE 17-1/2" 2 - 14" X 20" X 1" 21" 2 - 16" X 20" X 1" 24-1/2" 2 - 16" X 20" X 1" DOWNFLOW/HORIZONTAL FILTER DOWNFLOW (Vertical) FILTER TABLE The Problem Solver ▲...
  • Page 9: Regular Dealer Maintenance

    User’s Information Regular Dealer Maintenance ▲ Regular maintenance to be performed by a qualifi ed CAUTION service professional ONLY. Do NOT touch igniter. It is extremely hot. The following warning complies with State of California law, Proposition 65. ▲ ▲ WARNING WARNING HAZARDOUS GASES!
  • Page 10 User’s Information NOTE: On LP (propane) units, some light yellow tipping of the outer mantle is normal. Inner mantle should be bright blue. Natural gas units should not have any yel- low tipped fl ames. This condition indicates that a ser- vice call is required.
  • Page 11 User’s Information Limited Warranty High Efficiency Condensing Gas Furnace UH3, DH3, UX2, DX2, UH2, DH2, UX1, DX1, UX1-H, DX1-H, UX, DX, UY and DY (First letter may be preceded by an “A” or “T”) (Parts Only) Models Less Than 20 Tons for Residential Use* This limited warranty is extended by the manufacturer to the original purchaser and to any succeeding owner of the real property to which the gas furnace is originally affixed and applies to products purchased and retained for use within the U.S.A.
  • Page 12: Limited Warranty

    * This warranty is for commercial usage of said equipment and not applicable when the equipment is used for a residential application. Com- mercial use is any application where the end purchaser uses the product for other than personal, family or household purposes. As an ENERGY STAR Partner, Trane has determined that this product meets the ENERGY STAR guidelines for energy effi...

This manual is also suitable for:

Uh3Dh3Ux2Dx2Uh2Dh2 ... Show all