Hide thumbs Also See for VPL-EW130:

Advertisement

Quick Links

DATA PROJECTOR
VPL-EW130
VPL-SX125
VPL-SW125
PROTOCOL MANUAL
1st Edition (Revised 1)

Advertisement

Table of Contents
loading

Summary of Contents for Sony VPL-EW130

  • Page 1 DATA PROJECTOR VPL-EW130 VPL-SX125 VPL-SW125 PROTOCOL MANUAL 1st Edition (Revised 1)
  • Page 2 électrique, d’incendie ou de blessure n’effectuer que les réparations indiquées dans le mode d’emploi à moins d’être qualifi é pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. VPL-EW130...
  • Page 3: Table Of Contents

    AMX Device Discovery ........... 10 4. Ethernet 4-1. Service ................11 4-1-1. Advertisement ............11 4-1-2. PJ Talk ..............12 4-2. Communication Procedure ..........13 4-3. Protocols ................14 4-3-1. SDAP ..............14 4-3-2. SDCP............... 15 4-3-3. PJLink ..............24 1 (T) VPL-EW130...
  • Page 5: Introduction

    Table 1-2 Common Portions in Protocol Stack Layer Name Description Sub Command Value is assigned for projector’s functions. Refer to the section 2-1 for detail description. Simplifi ed Command Packet format for sending/receiving “Sub Command”. Refer to the section 3-6-1 for detail description. VPL-EW130...
  • Page 6 Because of traditional portions for Ethernet general layer, “TCP/IP”, “UDP/IP” and “HTTP” are out of scope in this document. SDCP specifi c command is described in the section 4-3-2. SDAP and SDCP (PJ Talk) are SONY original protocol stack, which are described in the sections 4-3-1 and 4-3-3 respectively. VPL-EW130...
  • Page 7: Common Commands

    Set/Get STANDARD 0001h PRESENTATION 0002h GAME 0003h LIVING 0004h CINEMA 0005h CONTRAST VALUE 0000h-0064h(0-100) BRIGHTNESS VALUE 0000h-0064h(0-100) COLOR VALUE 0000h-0064h(0-100) VALUE 0000h-0064h(0-100) SHARPNESS VALUE 0000h-0064h(0-100) VOLUME VALUE 0000h-0064h(0-100) COLOR TEMP HIGH 0000h 0001h 0002h 0000h PROGRESSIVE 0001h FILM 0002h VPL-EW130...
  • Page 8 *1: For using this item number, the simulation of the infrared remote controller is enable. Select the corresponding code in the table of Section 2-1-2 and use it as the lower byte of the item number. Other value (the upper byte) is assigned depending for category. VPL-EW130...
  • Page 9 Get only LAMP ERROR FAN ERROR COVER ERROR TEMP ERROR STATUS POWER STANDBY STARTUP LAMP POWER ON COOLING1 COOLING2 SAVING COOLING1 SAVING COOLING2 SAVING STANDBY LAMP TIMER VALUE SUB ROM VERSION VALUE MAIN ROM VERSION VALUE STATUS SECURITY DISABLE ENABLE VPL-EW130...
  • Page 10: Infrared Remote Command Code

    VPL-EW130...
  • Page 11: Reply

    1 START Bit + 8 DATA Bits + 1 PARITY Bit + 1 STOP Bit START PARITY STOP (LSB) (MSB) (EVEN) EVEN Parity ...Total number of “1”s from D0 to D7 is an even number. 8 0 ...Total number of “1”s from D0 to D7 is an odd number. 8 1 VPL-EW130...
  • Page 12: Communication Procedure

    . For POWER ON/OFF/TOGGLE of the SIRCS direct command, send the command twice when this unit is in standby mode (Low) state. 3-5. Approximate Return Waiting Times The await-return time is approx. 30 to 1000 msec. This is the case, unless the communications are interfered anyway. VPL-EW130...
  • Page 13: Command Block Format

    END CODE *1: CHECK SUM: B1 to B5 are calculated by OR. Refer to the example below. <Example of Calculation> 0xA9 1010 1001 0xA9 1010 1001 0xA9 1010 1001 0x9A 1001 1010 Answer 1010 1001 Answer 1011 1011 0xA9 0xBB VPL-EW130...
  • Page 14: Packet Examples

    DATA = 0000h CHECK SUM = 7Fh END CODE = 9Ah 3-8. AMX Device Discovery This model is equipped with the protocol that conforms to the Device Discovery stipulated by AMX. Con- tact AMX for details about the Device Discovery. VPL-EW130...
  • Page 15: Ethernet

    Broadcast interval Once every 30 seconds (Factory-shipments value) [Setup Items] The items that can be set for the advertisement service are described below. Setup items Description Port No. Port number Interval Broadcast interval Broadcast Address Adding the transmission place. VPL-EW130...
  • Page 16: Pj Talk

    Transport Port number 53484 (Factory-shipments value) TCP connection timeout 30 seconds (Factory-shipments value) [Setup Items] Setup item Description Port No. Port number Timeout TCP connection timeout time Host Address PC address that is able to connect Community Header community VPL-EW130...
  • Page 17: Communication Procedure

    It is prohibited that CONTROLLER send another command before receiving the response to the previous command. Since PROJECTOR executes the command before sending the return data, CONTROLLER must wait a while before receiving the response. The waiting time depends on not only the commands but also network traffi c. VPL-EW130...
  • Page 18: Protocols

    SERIAL NO. Serial number is entered. POWER STATUS Power supply status of the equipment is entered. LOCATION Information of installation location (Maximum twenty four characters) In case, less than twenty four characters, 00h is entered in the blank space. VPL-EW130...
  • Page 19: Sdcp

    COMMUNITY fi eld should be consist of four alphanumeric characters (case sensitive). All display equipment has the default value “SONY” when shipped at the factory. COMMUNITY fi eld should be fi lled with four characters. Three characters or less are not allowed.
  • Page 20 3) DATA LENGTH sub fi eld This sub fi eld shows the length in byte of the DATA fi eld in the SDCP packet. The maximum data length is 128 bytes. If there is no data to be sent, its value should be 0h. VPL-EW130...
  • Page 21 3) DATA LENGTH sub fi eld This sub fi eld shows the length in byte of the DATA fi eld in the SDCP packet. The maximum data length is 128 bytes. If there is no data to be sent, its value should be 0h. VPL-EW130...
  • Page 22 This is for acquiring information of PROJECTOR. While the higher byte is fi xed as 80h shown in the table above, the lower byte is defi ned as follows. Lower byte Contents Category Code Model name Serial number Installation location 0x8000 Category code 1 byte VPL-EW130...
  • Page 23 MAC Address IP Address Subnet Mask Default Gateway DHCP 0x9000 Mac Address 6 bytes 0x9001 IP Address 4 bytes 0x9002 Subnet Mask 4 bytes 0x9003 Default Gateway 4 bytes 0x9004 DHCP 1 byte DHCP disable: 0 DHCP enable: 1 VPL-EW130...
  • Page 24 Invalid Category Invalid Request Short Header Short Community Short Command Network Error (20**h) Timeout Comm Error (F0**h) Timeout Check Sum Error Framing Error Parity Error Over Run Error Other Comm Error Unknown Response NVRAM Error (F1**h) Read Error Write Error VPL-EW130...
  • Page 25 An item that is not valid at present is specifi ed. Example: The item to switch the display is specifi ed when the main power is off. (2) Community Error This error occurs when community is different. Example: “ABCD” is specifi ed when “SONY” is set. VPL-EW130...
  • Page 26 The received data is in the range of two to fi ve bytes. Short Command The received data is in the range of six to nine bytes. (4) Network Error There is something wrong with TCP/IP. Timeout Communication was interrupted. VPL-EW130...
  • Page 27 8. Packet Examples For setting the picture mode to dynamic, the packet should be as follows. HEADER (VERSION, CATEGORY) = (02h, 0Ah) COMMUNITY = “SONY” = (534F4E59h) COMMAND (REQUEST, ITEM NO, DATA LENGTH) = (00h, 0002h, 02h) DATA = 0000h The same result can be obtained by using ENCAPSULATION mode as well.
  • Page 28: Pjlink

    Sets the projector’s video + audio muting. AVMT ? The following values are returned: 11 : Projector video muting ON 21 : Projector audio muting ON 30 : Projector video + audio muting OFF 31 : Projector video + audio muting ON VPL-EW130...
  • Page 29 . Maximum number of controllers simultaneously connected 1 unit . Authentication setting Can be set on the Web screen. The default settings are as follows: Authentication setting : Enabled Password : JBMIAProjectorLink When the authentication setting is changed, the connected controller will be disconnected. VPL-EW130...
  • Page 30 When processed properly : Returns “OK”. When parameter is out of range : Returns “ERR2”. Unacceptable period (when the power status is other than Standby or Power ON) : Returns “ERR3”. Projector error occurring (including warning) : Returns “ERR4”. VPL-EW130...
  • Page 31 The projector responds as follows: When processed properly : Returns “OK”. When inexistent input is specifi ed : Returns “ERR2”. Unacceptable period (when the power status is other than Power ON) : Returns “ERR3”. Projector error occurring (including warning) : Returns “ERR4”. VPL-EW130...
  • Page 32 When the projector video + audio muting is ON : Returns “31”. When the projector video + audio muting is OFF : Returns “30”. Unacceptable period (when the power status is other than Power ON) : Returns “ERR3”. Projector error occurring (including warning) : Returns “ERR4”. VPL-EW130...
  • Page 33 40 1 Unlit 40 0 40 1 20 1 Unlit 40 1 20 0 Unlit 40 0 20 1 Unlit Unlit 40 0 20 0 Projector error occurring (including warning) : Returns “ERR4”. VPL-EW130...
  • Page 34 (11) [Manufacturer name inquiry] INF1? This command obtains the manufacturer name. The projector responds as follows: When normal : Returns a manufacturer name (SONY). Projector error occurring (including warning) : Returns “ERR4”. (12) [Model name inquiry] INF2? This command obtains the model name.
  • Page 35 Returns a space. Projector error occurring (including warning) : Returns “ERR4”. (14) [Class information inquiry] CLSS? This command obtains the class information. The projector responds as follows: When normal : Returns “1”. Projector error occurring (including warning) : Returns “ERR4”. VPL-EW130...
  • Page 37 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 38 VPL-EW130 (CN) VPL-EW130 (SY) VPL-SX125 (CN) VPL-SX125 (SY) VPL-SW125 (CN) Printed in Japan Sony Corporation VPL-SW125 (SY) E 2011. 6 32 9-968-822-02 ©2011...

This manual is also suitable for:

Vpl-sx125Vpl-sw125

Table of Contents