Download Print this page

Kenwood TS-440S Serivce Manual page 90

Hf transceiver
Hide thumbs Also See for TS-440S:

Advertisement

TS-440 S
16. Directional Couple r
17. Power suppl y
PS-43 0
18. Microphon e
MC-60A or MC-42S
ADJUSTMENT
<REFERENCE >
Japanese "SG"
American "SG "
– 6 dB
0 .25µ V
0 dB
0 .5µV
6 dB
1µ V
12 dB
2µ V
OUTPUT
24 dB
8µ V
30 dB
1 5 .8µ V
1N60
T
loop
Q GND
40 dB
50µV
1 5
50 dB
8µ V
60 dB
500µ V
70 dB
1 .58m V
80 dB
5m V
90 dB
15 .8m V
100 dB
50mV
120 dB
0 .5V
14 . Spectrum Analyzer (SPE-ANA )
1) Frequency range : 100kHz to 110MHz or greate r
2) Bandwidth : 1 kHz to 3MH z
15 . Detecto r
1) For adjustment of PLL/VC0 BPF
0
2 .
3 .
4 .
5 .
6 .
90