Diversified Power International Accusense Charge Series Instruction Manual

Diversified Power International Accusense Charge Series Instruction Manual

Fully automatic battery charger

Advertisement

ACCUSENSE CHARGE SERIES
FULLY AUTOMATIC BATTERY CHARGER

SPECIFICATIONS:

Part Number: 1-48C017CXX-XXXX
Input:
Output:
Safety Timer:
IMPORTANT: READ AND SAVE THIS SAFETY
KEEP IT WITH OR NEAR CHARGER AT ALL TIMES
Diversified Power International
(423) 538-9002 (423) 538-9202 (fax)
120Vac, 10Aac,
48Vdc,
17/14 Adc
17 Hours
INSTRUCTION MANUAL.
414 Century Court
Piney Flats, TN 37686
www.DPIpower.com
Mode-1
Use for US Battery
Mode-2
Use for Trojan T875
Mode-3
Use for Trojan T105
Mode-4
Use for 36v
60Hz
1

Advertisement

Table of Contents
loading

Summary of Contents for Diversified Power International Accusense Charge Series

  • Page 1: Specifications

    Diversified Power International 414 Century Court Piney Flats, TN 37686 (423) 538-9002 (423) 538-9202 (fax) www.DPIpower.com ACCUSENSE CHARGE SERIES FULLY AUTOMATIC BATTERY CHARGER SPECIFICATIONS: Part Number: 1-48C017CXX-XXXX Mode-1 Use for US Battery Mode-2 Use for Trojan T875 Mode-3 Use for Trojan T105...
  • Page 2: Table Of Contents

    After completion of charge, charger will monitor battery voltage levels • 2. Introduction The Diversified Power International (DPI) battery charger is designed to recharge deep-cycle, lead-acid batteries. It is factory preset to operate in one of 3 different charge modes; refer to Section 6 for further details.
  • Page 3: User Safety

    3. User Safety Operations Guide WARNING - RISK OF EXPLOSIVE GASES. WORKING WITH LEAD-ACID BATTERY IS DANGEROUS. EXPLOSIVE GASES DEVELOP DURING NORMAL BATTERY OPERATION. READ THIS MANUAL EACH TIME AND MAKE CERTAIN YOU FULLY UNDERSTAND IT AND FOLLOW THE SAFETY AND OPERATING INSTRUCTIONS AT ALL TIMES.
  • Page 4: Installation

    NEVER charge a frozen battery. Thaw it out for safer and more • efficient charging. 4. Installation The AC line, to which the charger is to be connected, must be capable of supplying 10 amperes to this charger. CAUTION: TO REDUCE THE RISK OF FIRE, USE THIS CHARGER ONLY ON CIRCUITS PROVIDED WITH A MAXIMUM OF 20 AMPERE BRANCH CIRCUIT PROTECTION (CIRCUIT BREAKER OR FUSE), IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,...
  • Page 5: Grounding

    5. Grounding Instructions This battery charger must be grounded to reduce the risk of electric shock. This charger is equipped with an AC cord set having an equipment-grounding conductor. This AC cord set must be connected to an appropriate receptacle that is properly installed and grounded in accordance with the National Electrical Code and all local codes and ordinances.
  • Page 6 DANGER: RISK OF ELECTRIC SHOCK! DO NOT TOUCH ANY UNINSULATED PARTS OF THE CHARGER OUTPUT CONNECTOR, BATTERY CONNECTOR, OR BATTERY TERMINALS. DANGER: VISUALLY AND MANUALLY INSPECT TO VERIFY THAT THE DC OUTPUT CORD SET, PLUG AND BATTERY CHARGING RECEPTACLE ARE IN GOOD WORKING CONDITION BEFORE EACH AND EVERY USE AND DO NOT USE THE CHARGER IF: The DC charging receptacle does not grip the DC cord set plug tightly, •...
  • Page 7: 5-Stage Charge

    WARNING: WHENEVER REMOVING AC OR DC CORD SET PLUGS FROM RECEPTACLES, PULL FROM THE PLUGS’ BODY AND NOT FROM THEIR RESPECTIVE CORDS. 7. 5-STAGE CHARGE • If the charger’s AC cord set is first connected to AC power, while the charger’s DC cord set is left unconnected, the L.E.D.s will remain off and no power is delivered to the charger’s internal circuitry due to an internal relay, which remains in the ‘OFF’...
  • Page 8 7.3. STAGE THREE - CONSTANT VOLTAGE CHARGE (Absorption Charge) 7.3.1. Yellow L.E.D. remains illuminated continuously, but the charger now regulates voltage and not current. While the charger maintains a constant voltage, the charge current gradually decreases. 7.3.2. When the charger has determined the battery pack has reached 80-90% capacity, the Yellow and Green L.E.D.s both illuminate.
  • Page 9: E.d. Display

    8. L.E.D. DISPLAY Under normal charge circumstances, the L.E.D.s operate as follows: Power On (Red) Illuminates continuously when AC power power is present. Refer to the section ‘TROUBLESHOOTING’ if Flashing. Abnormal Shutdown (Red) Normally not illuminated. Refer to ‘TROUBLESHOOTING’ if Flashing. Detection Error (Red) Normally not illuminated.
  • Page 10 WARNING: DO NOT OPERATE THE CHARGER IF IT IS MALFUNCTIONING. PERSONAL INJURY OR PROPERTY DAMAGE COULD RESULT. If any of the three red L.E.D.s flash, the charge cycle has terminated prematurely. An abnormal charging condition was detected and charging stopped due to a Charge Error Condition. Refer to the following Charge Error Table for a description of the possible failure or condition.
  • Page 11 Excessive Overload. In the unlikely event that a heavy load is placed • across the battery pack while the charger is trying to charge the battery, and the charger cannot keep up with supplying energy to both the battery and the load, then the battery voltage will decrease. Further charging is terminated.
  • Page 12: Wiring Diagram

    10. Schematic Drawing 11. Parts List The items listed below refer to the Exploded View Drawing, following the list. If replacement items are needed, please reference the P/N and Model. ITEM P/N DESCRIPTION IPC021 AC Cord Set HDS009 AC Cord Set Strain Relief HDS056 Bumper Foot HDW069...
  • Page 14: Limited Warranty

    12. LIMITED WARRANTY Diversified Power International LLC (DPI) warrants exclusively to the original purchaser that this product will be replaced or repaired, at DPI’s option, if it fails during the first 2 years after date of purchase due to a defect in material or workmanship.

This manual is also suitable for:

Accusense charge 1-48c017c series

Table of Contents