Celair  Profile Series Owner's Manual

Celair Profile Series Owner's Manual

Domestic ducted evaporative air conditioning

Advertisement

Owner's Manual
Using your
Domestic Ducted Evaporative Air Conditioning
with the
Climate Control
Celair Profile Series
Operating, Setup & Maintenance
www.celair.com.au
Please keep this important manual in a safe place. It is the owner's responsibility to ensure that
regular maintenance is carried out on this Evaporative Air Conditioner. Failure to do so will void all
guarantees beyond statutory and legal requirements.
TEK600 SERIES CONTROL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Celair Profile Series and is the answer not in the manual?

Questions and answers

Allan
February 3, 2025

how do I gain access to the unit via pads area

1 comments:
Mr. Anderson
February 10, 2025

The manual does not provide specific instructions on accessing the Celair Profile Series unit via the pads area.

This answer is automatically generated

Summary of Contents for Celair Celair Profile Series

  • Page 1 Using your Domestic Ducted Evaporative Air Conditioning with the Climate Control Celair Profile Series Operating, Setup & Maintenance www.celair.com.au Please keep this important manual in a safe place. It is the owner’s responsibility to ensure that regular maintenance is carried out on this Evaporative Air Conditioner. Failure to do so will void all guarantees beyond statutory and legal requirements.
  • Page 2: Table Of Contents

    ’ ROFILE ERIES WNER ANUAL Contents ......................4 NTRODUCTION ..............5 UCTED VAPORATIVE ONDITIONER ........................5 NTRODUCTION Exhaust ............................5 Dialflo .............................. 6 Optional Dump Valve ........................6 ..................7 PERATING THE ONTROLS Manual Operation..........................7 Fan Only............................7 Fan & Pump ..........................7 Turning off Unit..........................
  • Page 3 ’ ROFILE ERIES WNER ANUAL Contents Setting the dump delay ......................... 15 Setting the Pre-cool........................16 Setting the Dump Interval Cycles....................16 Setting the Pre-fill (2 + 4 hour light on and the Auto light flashing)..........16 Reviewing Programmed Settings....................17 Setting the Thermostat Control Minimum / Maximum speed settings.
  • Page 4: Introduction

    ’ ROFILE ERIES WNER ANUAL Introduction INTRODUCTION ONGRATULATIONS ON YOUR CHOICE We are delighted you have chosen an air conditioning product from Climate Technologies to cool your home. It’s an air conditioner we’re very proud of. Designed and made in Australia by Climate Technologies, 100% Australian owned company, it contains the latest advances in Fresh Air Conditioning technology in a stylish, attractive cabinet.
  • Page 5: Ducted Evaporative Air Conditioner

    ’ ROFILE ERIES WNER ANUAL Ducted Evaporative Air Conditioner DUCTED EVAPOR AT IVE AIR COND ITIONER NTRODUCTION The Ducted Evaporative Air Conditioner is engineered to meet the rigors of our harsh Australian environment. Operated and maintained in accordance with this manual, it will provide you with years of quiet, cool and environmentally friendly operation.
  • Page 6: Dialflo

    ’ ROFILE ERIES WNER ANUAL Ducted Evaporative Air Conditioner Dialflo BLEED OFF All evaporative air conditioners need some water bleed-off to prevent build-up of mineral deposits in the system. correct setting of the bleed rate will ultimately govern the life of the unit.
  • Page 7: Operating The Controls

    ’ ROFILE ERIES WNER ANUAL Controls Operation OPER ATIN G TH E CONTR OL S Your ducted evaporative air conditioner has been supplied with the 4-button Climate control. The Climate controller has two modes of operation, MANUAL or AUTOMATIC. In addition it has a TIMER, which will operate in either mode.
  • Page 8: Timer Function

    ’ ROFILE ERIES WNER ANUAL Controls Operation Timer Function The timer function operates either in Automatic or Manual modes and is designed to switch the unit ON or OFF in a pre-set period (two, four or eight hours). Note: Once the time function has activated or deactivated the unit, it will remain in this mode until another selection has been made at the wall control.
  • Page 9: Unit Maintenance

    ’ ROFILE ERIES WNER ANUAL Unit Maintenance UNIT M AINT EN ANCE Warning: Before commencing any maintenance work on your unit, isolate the power at the supply (Fuse Box). Note: It is essential that your evaporative air conditioner be maintained in accordance with this manual.
  • Page 10: Water Distribution

    ’ ROFILE ERIES WNER ANUAL Unit Maintenance ATER ISTRIBUTION Check the water distribution system for blockage. Check the delivery tube for kinks or holes. Check that the clamps are secure and in place. ROBLEM OLVING PROBLEM PROBABLE CAUSE REMEDY Black - out Wait Tripped Circuit Breaker Reset...
  • Page 11: C S & C

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning CONTROL SETUP & COMM ISSIONING Your evaporative air conditioner has been supplied with the Climate Low voltage control featuring basic control options and thermostat, timed delayed starting and stopping, and dump valve features. This low voltage controls are connected to the air conditioner control box via a 20-metre low voltage loom.
  • Page 12: Control Location

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning ONTROL OCATION Climate wall control: • Locate the wall switch on an internal wall of a conditioned room of the home, approximately 1.5M above the floor level, in an easily accessible location as agreed with the customer.
  • Page 13: Tek 600 Wiring Diagram

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning TEK 600 W IRING IAGRAM TEK600 S Page 13 ERIES ONTROL...
  • Page 14: Climate Control - Setup Options

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning – S LIMATE ONTROL ETUP PTIONS This controller has a number of options for the installer to set before commissioning the unit. Options OPERATION FUNCTION This mode controls the dump valve. (If fitted). The dump delay is used to set the dump valve to dump 40 seconds DUMP after the pump is turned off or can be set to dump one hour after the...
  • Page 15: Parameter Settings Table

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning Parameter Settings Table The below table is a parameter chart for setting the unit. This chart is also printed on the back of the wall switch. Setting Installer Parameters. Press and hold the FAN+TIMER buttons for 10 seconds, release, and press the TIMER button once Parameters Dump delay...
  • Page 16: Setting The Pre-Cool

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning Setting the Pre-cool. (4 hour light on and Auto light flashing). 1. To disable the Pre-cool feature rotate the dial fully to the minimum position and the auto light will flash once every two seconds. 2.
  • Page 17: Reviewing Programmed Settings

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning Reviewing Programmed Settings. To review the settings entered into the Climate control, enter the parameter setting mode as explained from steps one to four on Page 15. Once entering the parameter setting mode DO NOT ROTATE THE ADJUSTABLE DIAL. Read the number of flashes from the AUTO light in with the two-hour light on.
  • Page 18: Setting The Thermostat Control Minimum / Maximum Speed Settings

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning Setting the Thermostat Control Minimum / Maximum speed settings. 1. Start with the wall switch in the off mode. 2. Press and hold the auto and timer buttons for ten seconds then release, after releasing these two buttons press and release the timer button once.
  • Page 19: Commissioning Check List

    ’ ROFILE ERIES WNER ANUAL Controls Setup & Commissioning OMMISSIONING HECK General Areas of high water pressure All equipment ordered by the customer (Exceeding 500Kpa) a water pressure is installed. limiting valve must be fitted in The unit is level and secure. accordance with AS3500.
  • Page 20: Warranty

    ’ ROFILE ERIES WNER ANUAL Warranty – Australia ONLY W ARRANT Y IMPORTANT: Please read this warranty information and complete the Dealer/Product information on the following page. KEEP this with your original purchase documents for any claim under warranty. Firstly refer to your owners manual to ensure you have followed the correct operating procedures of your product, and refer to the trouble shooting guide to assist solving any problems you may have.
  • Page 21 ’ ROFILE ERIES WNER ANUAL Warranty – Australia ONLY Exclusions to Warranty. • Consumable items subject to wear and tear such as filter pads drive belts and bearings are not covered by this warranty. • Components used as part of the installation such as grilles, filters, ducting, fittings, zone motors and consumer services pipe work are warranted from your place of purchase and not covered by this warranty.
  • Page 22 ’ ROFILE ERIES WNER ANUAL Warranty – Australia ONLY PERIODS OF WARRANTY – YEARS BY PRODUCT AND APPLICATION: Ducted Evaporative Air Conditioning - Domestic Unit Components RESIDENTIAL COMMERCIAL Parts Labour Parts Labour Corrosion on Cabinet Structural Guarantee ** All other components ** Filter pads are a consumable and are therefore not covered by this warranty 2 Year Extended Warranty Where a 2 year extended warranty has been sold / provided, a validation service must be conducted...
  • Page 23: Service

    ’ ROFILE ERIES WNER ANUAL Warranty – AUSTRALIA ONLY SER VIC E SERVICE CENTRES: Only qualified service personnel should conduct any service work carried out on your ducted air conditioning system. It is important that periodical service is carried out on your product to ensure your will receive the efficiency benefits the product provides.
  • Page 24 Manufactured by Climate Technologies ABN 13 001 418 042 26 Nylex Avenue Salisbury, SA 5108 Australia www.celair.com.au 6062203B...

Table of Contents

Save PDF