RF62 User Guide Table of Contents Table of Contents ................1 About this Document ................ 2 Declaration of conformity ..............3 Compliance to FCC US/CAN .............. 4 Overview ................... 5 Interface ................... 6 Mechanical specification ..............6 Power supply input ................6 External Power Supply &...
Crolles, December 5th, 2008 VINCENT Hervé / Quality manager Download of the user guide Thank you for having chosen the ADEUNIS RF products. User guides can be uploaded directly on our web site www.adeunis-rf.com Index Products Paragraph Bluetooth®...
-- Consult the dealer or an experienced radio/TV technician for help. CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY ADEUNIS RF COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. RF Exposure Warning: During operation, the user may keep a minimum separation distance of 20 cm with the RF devices.
RF62 User Guide Overview RF62 ® The A Bluetooth class 1 dongle enables Bluetooth compliant duplex communications over a 150-meter range in the worldwide 2.45 GHz frequency band. RF62 ® The A dongle fully complies with the V2 Bluetooth standard and air data rate goes up to 723 kbps.
Mechanical specification 65 x 40 x 25 mm Power supply input ARF62 dongles may be supplied using an external power supply through µJack plug (default) or through RI pin / DB connector. Selection is done with an internal onboard jumper:...
RF62 User Guide NOTE : ARF62 external power supply is done through a female ∅3.5 mm DC µJack (Positive on inner pin ∅1.3 mm) Signal description ARF750X Bluetooth Dongles pinout. Interface Interface Interface Description Name ARF7501 ARF7502 ARF7503 Fem DB9...
RF62 User Guide SPP wiring and configuration ® SPP (Serial Port Profile) is the standard Bluetooth profile. ARF62 ARF62 Bluetooth Bluetooth Dongle Dongle (DTE (DTE) Master Slave DCDRI SPP configuration guideline : in the following example, the Master is configured to performed an auto-connection on reset.
AT&L command). DUN wiring and configuration DUN (Dial up Network) profile is above the SPP profile. This profile manages the 4 lines DTR, DSR, DCD and RI and is dedicated to PSTN or GSM modems. ARF62 ARF62 Modem (DTE)
RF62 User Guide activated master. When the link is established data can be exchanged using the serial link. Caution the BT connection establishment can takes several seconds (you can check this establishment either in command mode using the AT&L command or by checking report of a remote signal).
When data are received on the radio link, these data are sent on the serial link. Remote control configuration SPP_CONFIG mode is used to remotely configure the slave dongle through the master dongle serial link. ARF62 ARF62 Bluetooth Bluetooth DCE Dongle...
RF62 User Guide AT Commands Description AT commands are interpreted only when the dongle is in Command mode. Commands : are used to read and update the dongle parameters A command starts with the 2 ASCII ‘AT’ characters. ‘AT’ means ‘Attention’ follow with one or several characters or other data.
Page 15
-80 > RSSI > -90 dBm : Poor receipt RSSI < -90 dBm : Bad receipt Miscelleanous Software version display. The response has the following format: Adeunis RF : 7456 Vxx.yy<cr><lf> ATC0 Exit SPP Config mode ATC1 Enter SPP Config mode Test modes Ref.
RF62 User Guide AT&T0=xxxx,yyyyy, Continuous transmission at xxxx (2402<=xxxx<=2480) MHz, with zzzzz a designated output power yy (0<=yyyy<=65530) and designated tone modulation frequency zzzzz (0<=zzzzz<=65535). Example : AT&T0=2450,65530,0 AT&T1=xxxx, yyyyy Enables the transmitter at xxxx (2402<=xxxx<=2480) MHz, with a designated output power yy (0<= yyyyy <=65530). Payload is PRBS9 data.
Page 17
RF62 User Guide Type Register Function Description Default value Link disconnection if register value change Bluetooth management S200 Local Bluetooth Local Bluetooth address address of the dongle The local BT address is read only. S201 Local device Device name “Serial Port name must be lower or Device”...
Page 18
RF62 User Guide Type Register Function Description Default Link disconnection value if register value change S210 Baudrate Serial link rate in bits/s IMPORTANT see Note 1 (See Note 1) ‘4’: 9 600 ‘5’: 19 200 ‘6’: 38 400 ‘7’: 57 600 ‘8’: 115 200 S211 Data length...
Page 19
RF62 User Guide S232 Sniff see Note 2. parameter 0..1342 Min interval Sniff offset (Dsniff) – multiply 625us Dsniff must be lower or equal to Tsniff-2 S233 Sniff 0..672 parameter Number of slots listen by slave Attempt during wake-up Sniff parameter attempt must be lower than Tsniff/2 S234 Sniff...
RF62 User Guide Annex 1 : Firmware and document updates Firmware Updates ARF745XXB-V1.06 Firmware default data rate is now 9600 bps. Default data rate is 9600 bps and “Restore register default value – AT&F” gives data rate back to 9600 bps ARF745XXA-V1.05 Original version.