Trouble Shooting - Buffalo CD963 Instruction Manual

Gas griddle
Table of Contents

Advertisement

Trouble shooting

This section provides an easy reference guide to the more common problems that may occur during the
operation of your equipment. The fault finding guide in this section is intended to help you correct, or at
least accurately diagnose problems with your equipment.
Although this section covers the most common problems reported, you may encounter a problem not
covered in this section. In such instances, please contact your local authorised service agent who will
make every effort to help you identify and resolve the problem. Please note that the service agent will
require the following information:
• The Model Trade Name and the Serial Number of the Appliance. (Both of them can be
found on the Rating label located on the appliance.
Fault
Pilot won‟t light.
Pilot goes out when gas control
knob released.
Main burner will not light.
NOTE: Components having adjustments protected by the manufacturer, are only allowed to be adjusted by
an authorised service agent. They are not to be adjusted by an unqualified service person.
Possible Cause
No gas supply.
Blocked pilot injector.
Releasing knob before the
thermocouple has heated.
Pilot flame too small.
- Gas pressure too low.
- Partially blocked pilot injector.
Thermocouple faulty.
Incorrect supply pressure.
Faulty gas control.
12
Remedy
Ensure gas isolation valve is
turned on, and that bottles are
not empty.
Call service provider.
Hold knob in for at least 20
seconds following ignition of
pilot.
Call service provider.
Call service provider.
Call service provider.
Call service provider.

Advertisement