Diagnostic Fault Code Storage And Retrieval - York GY8S Series User's Information, Maintenance And Service Manual

Upg high efficiency tubular heat exchanger series (single stage upflow / horizontal / lownox)
Hide thumbs Also See for GY8S Series:
Table of Contents

Advertisement

268893-UUM-A-0407
DIAGNOSTIC FAULT CODE STORAGE AND
RETRIEVAL
The control in this furnace is equipped with memory that will store up to
five error codes to allow a service technician to diagnose problems
more easily. This memory will be retained even if power to the furnace
is lost. This feature should only be used by a qualified service tech-
nician.
The control stores up to five separate error codes. If more than five
error codes have occurred since the last reset, only the five most recent
will be retained. The furnace control board has a button, labeled "LAST
ERROR" that is used to retrieve error codes. This function will only work
if there are no active thermostat signals. So any call for heating, cooling
or continuous fan must be terminated before attempting to retrieve error
codes.
(Seconds)
THERMOSTAT
INDUCER
IGNITOR
MAIN VALVE
HUMIDIFIER
ELECTRONIC
AIR CLEANER
CIRCULATING
BLOWER
FIGURE 10: Furnace Control Event Schedule
8
Thermostat Calling for Heat
0 2
17
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
To retrieve the error codes, push the LAST ERROR button. The LED on
the control will then flash the error codes that are in memory, starting
with the most recent. There will be a two-second pause between each
flash code. After the error codes have all been displayed, the LED will
resume the normal slow green flash after a five second pause. To
repeat the series of error codes, push the button again.
If there are no error codes in memory, the LED will flash two green
flashes. To clear the memory, push the LAST ERROR button and hold it
for more than five seconds. The LED will flash three green flashes when
the memory has been cleared, then will resume the normal slow green
flash after a five-second pause.
22
52
Fan on Delay
30 Seconds
OFF
ON
OFF
ON
OFF
ON
OFF
Thermostat Satisfied
0
OFF
OFF
15 Sec.
Post
Purge
OFF
OFF
OFF
OFF
OFF
60, 90, 120, 180 SEC.
Selectable Fan Off Delay
Unitary Products Group

Advertisement

Table of Contents
loading

Table of Contents