Dometic RM 3662 Installation And Operating Instructions Manual page 6

Refrigerator for lp-gas and electric operation
Table of Contents

Advertisement

'96
TIS
FSDF
CERTIFIED INSTALLATION
Certified installations require one roof vent and one
lower side vent.
For "Certified Vent System Kits" see page 15.
For further information contact your dealer or distributor.
upper
NOTE: The
vent should be
centered over the condenser coil
at the beck of the refrigerator.
Minimum
ventilation ,
FIG.
9
METHODS OF INSTALLATION
The
method of installation is shown in FlG. 9. It is
essential that all maximum or minimum dimensions are
strictly maintained as the performance of the refrigerator
is dependent on adequate flow of air over the rear of the
refrigerator,
VENTILATION HEIGHTS
Installation with roof
vent and tower side vent
Refrigerator
RM3662, RM 3663
RM 3662; RM 3963
46 141 238393
Minimum ventilation
heights in
Inches
mm
57-3/4
1465
1620
HO
CLEARANCE%
Minimum clearances In inches to combustible materials
are:
G: Top
0
K:
Slde
0
L: Bottom 0
M: Rear 0
N:
See NOTE: Clearance "N" below.
NOTE: Clearance " M" is between the rearmost part of
the refrigerator and the wall behind the refrigerator.
NOTE: Clearance "N" is the distance between the bot-
tom of the lower vent to the roof material. For ventilation
height, see table VENTILATION HEIGHTS
See Figures 9, and 10.
Strip
NOTE: Wood
MUST be in place.