KEETEC TS MOTO User Manual

Motor cycle alarm system

Advertisement

User Manual
MOTOR CYCLE ALARM SYSTEM
KEETEC TS MOTO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS MOTO and is the answer not in the manual?

Questions and answers

Summary of Contents for KEETEC TS MOTO

  • Page 1 User Manual MOTOR CYCLE ALARM SYSTEM KEETEC TS MOTO...
  • Page 2 Press and hold button 1 & Ignition ON within 5 Enter function selection 4 for 2 sec seconds press button 2 & Ignition ON within 5 Enter/exit VALET mode together seconds Press button 4 Enter car finder mode Arming BUTTON TRANSMITTER Version1.2 TS MOTO...
  • Page 3 30 seconds. Trigger defence area In arming mode,if the defence area was triggered, siren will chirp 30 sec., parking light will flash 30 seconds. Note: up to 8 times to alarm per arming cycle. Version1.2 TS MOTO...
  • Page 4: Arming And Bypass Tilt Sensor

    10 sec, Press button1or2 to stop sounding and parking lights will flash for 10 seconds. AR FINDER The system is armed. Press button 4: siren will chirp once, parking lights will flash 10 times. Press button 2 to stop car finder and disarm. Version1.2 TS MOTO...
  • Page 5: Emergency Override

    NUMBER will be input, and turn ignition OFF, LED start to blink again;  When LED blink the same number as the 3rd digit of PIN NUMBER, turn ignition ON, 3rd PIN NUMBER will be input, and turn ignition OFF, LED start to blink again, Version1.2 TS MOTO...
  • Page 6: Enter Valet Mode

    This applies to all states of the system including arm, disarm, and valet mode. IGH FREQUENCY Your system transmits and receives at 433 MHz; this provides a cleaner spectrum with less interference and a more stable signal. Version1.2 TS MOTO...
  • Page 7: Function Selection

    (CHIRP ONCE) AUTO REARMING ANTI MOTORCYCLE- JACKING 1,2,3,4,5,7,9, Tilt SENSOR sensitivity 3(°) adjustment 11,15,30(°) Silent/chirp mode Silent Chirp mode Positive/Negative siren Negative siren Positive(constant) output output(pulse) Flash lamp arm/disarm Enable Disable Reset back to Factory DEFAULT setting Version1.2 TS MOTO...
  • Page 8: Power Saving Mode

    If any other input is activated when in sleep mode, the system will wake up, the siren will chirp 10 times. APPENDIX 1. E LECTRICAL CONFIGURATIONS DC Supply voltage DC Tolerance voltage 9V-16V ≤6mA Current (Static) ≤4mA Current (Sleep) Siren volume 105dB Version1.2 TS MOTO...
  • Page 9 2. I NSTALLATION GUIDE FUSE 15A LAMP Version1.2 TS MOTO...
  • Page 10 3. S MART NITE SIZE Version1.2 TS MOTO...
  • Page 11 4. S IREN SIZE Version1.2 TS MOTO...
  • Page 12 5. F INISHED GOOD Version1.2 TS MOTO...

Table of Contents