  • Page 1 Heat Pump / Air Conditioner With supplemental heat – 208v/230v INSTALLATION AND USER MANUAL BEFORE INSTALLING AND USING THIS AIR CONDITIONER PLEASE READ ALL INSTRUCTIONS CAREFULLY. Version 20110711.BL...
  • Page 2: Table Of Contents

    1.1 INTRODUCTION 1.2 IMPORTANT SAFETY INSTRUCTIONS 1.3 RECEIVING THE GOODS 1.4 HANDLING 1.5 LIST OF ACCESSORIES 1.6 TECHNICAL FEATURES 2.1 POSITIONING THE AIR CONDITIONER 2.2 PAPER TEMPLATE 2.3 DRILLING THE WALL 2.4 MOISTURE PROTECTING WALL 2.5 FASTENING THE BRACKET 2.6 FITTING THE GRATINGS 2.7 CONNECTING DRAIN PIPE 2.8 FITTING THE AIR CONDITIONER ON THE BRACKET 2.9 POWER CORD CONNECTION...
  • Page 3: Introduction

    1.1 INTRODUCTION Return the air conditioner to an authorized service centre for examination and repair to avoid a hazard. Please note: Do not dispose of any packaging until the installation of the air conditioner is completed. Do not attempt to repair or adjust any electrical or mechanical functions on this air conditioner as this After having removed the packing, check that all the may void the warranty.
  • Page 4: Receiving The Goods

    1.3 R E C EIV IN G T H E G O OD S The air conditioner is delivered in protective packaging and is accompanied by an instruction manual. When the air conditioner is unpacked, please check that the air conditioner and accessory package are complete and undamaged.
  • Page 5: Technical Features

    1.6 T EC H N IC AL F EA T U RE (P 1, P2 ) Model iWARM 2.3 Cooling capacity* (BTU/h) 7800 Heating capacity* (BTU/h) 6900 Heater* BTU 1500 Rated voltage (V) 208-230 Absorbed power in cooling* (W) Absorbed current in cooling* (A) 4.35 Absorbed power in heating* (W) Absorbed current in heating* (A)
  • Page 6: Positioning The Air Conditioner

    2.1 P O SIT IO N IN G T H E A IR 2.2 PA P E R T E M PLA T E (P4 ) CO N D ITIO N E R (P 3) Fasten the template to the wall once the following guidelines have been thoroughly checked.
  • Page 8: Drilling The Wall

    2.3 D R ILL IN G T H E WA LL (P6, 7, 8, DRA IN A GE H OL E (P8 ) This air conditioner has a system to drain the Please note: If you are drilling the hole above condensate moisture automatically.
  • Page 9: Moisture Protecting Wall

    2.4 M O IS T UR E PR O T E C TIN G W ALL SOLID WALL PROTECTION (P13, 14) EMPTY WALL PROTECTION (P10, 11, 12) If the wall is built of full brick or stone, for this kind of solid wall, it is recommended to use a If the wall is built with empty brick as shown in waterproof paint on the hole surface to protect the...
  • Page 10: Fitting The Gratings

    2.6 F IT T IN G T HE GR AT IN G S After drilling the holes, the plastic gratings supplied with air conditioner need to be fitted on the wall. 1. When gratings have easy accessibility, you may fix the gratings from outside. It is recommended to fasten them to the wall with wall plugs and screws with a diameter of .24 inches, keeping the fins in vertical position.
  • Page 11: Connecting Drain Pipe

    The black silicon gel is just for reference, white or 2.7 C O N N E C TIN G DR A INA G E P IP E transparent color gel may also be used to fix the outdoor grille.(P22) Connect the drain pipe to the back side of the air conditioner after unplugging the black rubber cup (see P24).
  • Page 12: Fitting The Air Conditioner On The Bracket

    2. When the machine is installed in a very cold environment, it would be preferable to connect the drainage pipe inside the wall. (P26) 2.8 F IT T IN G T HE A IR The appliance shall be installed in accordance CO N D ITI O NE R O N T H E B RA C K ET with national wiring regulations.
  • Page 13: Power Cord Connection

    2.9 POWER CORD CONNECTION 1. With every unit, there is a power cord on the left side (P32). Connect the plug to the socket, and operate the unit.
  • Page 14: Introduction Of Lcd Icons

    Super Heating Mode 5°...
  • Page 16: Super Heating Mode

    5°C.
  • Page 22: Front Panel Function

    3.12 F R O NT PA N E L F U N C T IO N (P33 ) When the unit starts working, the front panel and flap opens completely. 15 seconds later, the indoor fan and compressor work according to mode setting.
  • Page 23: Maintenance

    3.14 M A IN TE N A NC E (P3 5, 3 6, 3 7) FILTERS CLEANING: The filter should be cleaned regularly to keep the air conditioner running efficiently. Clean the filter every two weeks. How to proceed: -- Disconnect the air conditioner from the electrical supply.
  • Page 24: Problem Solving

    3.15 P R OB L E M S OL VIN G The maximum operating temperatures for the air conditioner: (max cooling: outdoor DB43 P O S SI BL E CA U S E WB26 , indoor DB32 /WB23 ; min heating: outdoor DB-5 /WB-6 ,indoor Db20 ) -The air conditioner does not work.