• control based on water volume flow EUV xx AI • scale change control EUV xx T, a TI Note.: Types EUV 15 Dom to EUV 25 Dom have only visual green LED diode signal marked “DESCALING” b) acoustic signal – type EUV xx MI, TI a AI •...
Page 3
Electronic scale eliminator ANTICA treatment and is rendered useless. However the installation of the device in open water circuits downstream of the reservoir or holding tank is beneficial. In closed water circuits the installation of the device upstream of the holding tank is highly recommended.
Page 4
Electronic scale eliminator ANTICA • For devices EUV xx AI connect to water volume measuring device. 2. From supplied power cable (red), wind on vertical or horizontal straight pipe 2 coils with the number of turns indicated in Table 1 and the distance between them indicated in Table 2. Please note that both windings must run in the same direction as shown on the installation diagrams for each type of the device.
Page 5
Electronic scale eliminator ANTICA Considerable effort should be made to monitor the system where the AntiCa device is installed. On older systems where scaling took place before the AntiCa device installation, the treated water softens the scaling and in time may restore the system to its original state. Depending on the severity of system scaling, the loose scale in piping systems with reduced flow velocity can settle in any place and invoke system blockage.
Page 7
Electronic scale eliminator ANTICA Technical data of EUV xx D. Water Flow Max. pipe Device dimensions diameter outs Input Type inside [VA] /hour [USGPM] [mm- [mm] [in] inch] EUV 10 D 0.1 - 0.45 1.6 - 4.75 10 (3/8") 160x96x67 EUV 15 D 0.3 - 1 4.75 -15.85...
Page 8
Electronic scale eliminator ANTICA Techical data of EUV xx T. Water flow Max. pipe Device dimensions diameter Input Internal Type [VA] /hour Ext. [USGAL] [mm- [mm] [in] [mm] inch] I. 0,.4 -1.4 15.85 - 22.19 EUV 32 T 32 (5/4") 215x130x82 8 II.
Page 9
Electronic scale eliminator ANTICA Technical dada of EUV xx MI, TI and AI. Max. pipe Device dimensions Water Flow diameter Type Input Internal Ext. MI, TI, AI [VA] /hr] [USGPM] [mm- [mm] [in] inch] EUV 50 0.2–11 3.17 -174.35 50 (2") 275x220x140 EUV 65 0.3–18...
Page 10
Electronic scale eliminator ANTICA Installation of EUV xx TI. L – distance between coil windings ( see. page.4) Installation of EUV xx AI. L – distance between coil windings (see. page.4)
Page 11
Electronic scale eliminator ANTICA Timer TM-6331 (Daily and weekly programming). Button functions: CLOCK Indication and time setting Day setting HOUR Clock setting Minutes setting TIMER Selection of individual time duration On/Off MANUAL Manual operation On/Off Accepts all settings and starts the program Installation: Take out the screw located on front panel in right corner.
Page 12
Electronic scale eliminator ANTICA Specifications of timers model TM 6331. Power 120VACV ,50 – 60 Hz 16 A / 250 V alternate. Cosφ=1 Max. current 20 A / 125 V alternate. Cosφ=1 Back-up Battery CR2032 Ambient temperatures -10 to + 50°C non-corrosive atmosphere Number of contacts 16 (8 NO and 8 NC) Programming...
Page 13
Electronic scale eliminator ANTICA Technical data for digital Volume measurement devices EUV xx AI. (OPTO OD 01, OD 02.) Sensor IR – reflection ray in accordance with DIN 19234 Specification 8,2 V DC ( z EUV xx Feeder voltage AI ) Reflection currant <...
Page 14
Electronic scale eliminator ANTICA Technical data of AntiCa devices Power 120 VACV, 50-60 Hz Room temperature +1 to + 50°C Pipe surface temperature EUV xx Dom max. 70 °C Other types max.150 °C Length of power coil cable max 1,5 m (red) Length of power cord EUV xx Dom...