HCW PASHW030 Installation Instructions Manual

HCW PASHW030 Installation Instructions Manual

50 000 / 80 000 btu swimming pool heat pump no reversible

Advertisement

HCW SWIMMING POOL HEAT PUMP
NO REVERSIBLE
PASHW030 - 50 000 btu
PASHW045 - 80 000 btu
Installation & Instruction Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PASHW030 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HCW PASHW030

  • Page 1 HCW SWIMMING POOL HEAT PUMP NO REVERSIBLE PASHW030 - 50 000 btu PASHW045 - 80 000 btu Installation & Instruction Manual...
  • Page 2: Table Of Contents

    CONTENTS …………………………………………………………… 1 1. Preface ……………………………..……………………… 2 2. Specifications 2.1 Performance Data of Swimming Pool Heat Pump Unit 2.2 ………………… 2 .. 3 2.2 Dimensions for Swimming Pool Heat Pump Unit …………………………... 3. Installation and Connection …………………………………………..4 3.1 Installation of system ………………………………………………... 4 3.2 Swimming Pool Heat Pump Location ………………………………...
  • Page 3: Preface

    1. PREFACE  In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacture of this product will not be held responsible if someone is injured or the unit is damaged, as a result of improper installation, debugging, or unnecessary maintenance.
  • Page 4: Specifications

    2. SPECIFICATION 2.1 Performance data of Swimming Pool Heat Pump Unit **** REFRIGERANT: R410A UNIT PASHW030-P PASHW045-P 14.7 23.4 Heating Capacity Btu/h 50 000 80 000 Heating Power Input Running Current 10.2 Power Supply 208-230V-/60Hz 208-230V-60Hz Compressor Quantity Compressor Rotary...
  • Page 5: Dimensions For Swimming Pool Heat Pump Unit

    2. SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit PASHW030-P Unit : inch PASHW045-P Unit : inch...
  • Page 6: Installation And Connection

    3. INSTALLATION AND CONNECTION 3.1 Installation illustration Installation items: The factory only provides the main unit and the water unit; the other items in the illustration are necessary spare parts for the water system, that provided by users or installer. ATTENTION : Please follow these steps when using for the first time: 1- Open valve and charge water...
  • Page 7: Swimming Pool Heat Pump Location

    3. INSTALLATION AND CONNECTION 3.2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided that the following three factors are presented: 1. Fresh - 2. Electricity - 3. Pool filter piping The unit may be installed virtually anywhere outdoor. For indoor pools please consult the supplier.
  • Page 8: Swimming Pool Heat Pump Plumbing

    3. INSTALLATION AND CONNECTION 3.2 Swimming Pool Heat Pumps Plumbing The Swimming Pool Heat Pump exclusive rated flow titanium heat exchanger requires no special plumbing arrangements except bypass (please set the flow rate according to the nameplate). The water pressure drop in less than 10 kPa at max. Flow rate. Since there is no residual heat or flame Temperature, The unit does not need copper heat sink piping.
  • Page 9: Swimming Pool Heat Pump Electrical Wiring

    3. INSTALLATION AND CONNECTION 3.5 Swimming Pool Heat Pumps Electrical Wiring NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit, it simply prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect you against short circuits inside the unit.
  • Page 10: Usage And Operation

    4. USAGE AND OPERATION 4.1 Function of wire controller Key Name Key function ON/OFF Pressure this key to turn on/off the unit MODE Mode Press this key to change the working mode CLOCK Timer Press this key to set system time ˚C/˚F Choose key Press this key to choose the Celsius degree or Fahrenheit degree...
  • Page 11: Usage Of The Controller

    4. USAGE AND OPERATION 4.2 Usage of wire controller 4.2.1 Turn ON/OFF the unit When the unit is off, press the key " " 0.5s to turned on the unit When the unit is on, press the key " " 0.5s to show down the unit 4.2.2 Mode switch You can choose unit mode (The function is only available for heating &...
  • Page 12 4. USAGE AND OPERATION 4.2.4 Setting temperature In main interface, press ‘’ ‘’ or ‘’ ‘’ and the current mode target-temprature flashes, then press ‘’ ‘’ to increase the temp. Value, or press ‘’ ‘’ to decrease it. Press ‘’MODE’’ can save setting parameter and back to the main interface. Press "...
  • Page 13 4. USAGE AND OPERATION 4.2.5 Clock setting In the main interface, press ‘’CLOCK’’ twice. Hours start to flashing, and press ‘’ ‘’ to increase value or press ‘’ ‘’ to decrease value, and press ‘’CLOCK’’ to setting. At the same time, minute start to flashing, press ‘’ ‘’...
  • Page 14 4. USAGE AND OPERATION 4.2.6 Timer setting (1) You can set the timer of the unit on In the on or off state, press ‘’TIMER ON’’ to enter timer-on interface. Press ‘’TIMER ON’’ And time-hour-bit flashing. Press ‘’ ‘’ or ‘’ ‘’...
  • Page 15 OFF’’, the other operation is the same as timer-on). For example : Hour Minute 4. USAGE AND OPERATION (2) The setting of cancelling the timer If there is no need to set timer on or timer off, the timer setting can be cancelled. At unit on or off state, press ‘’TIMER ON’’...
  • Page 16 4.2.6 Keyboard Lock To avoid mis-operation, please lock the controller after parameter setting. At the main interface, pressing " " for 5 seconds, when hearing one sound, the keyboard is locked. When the keyboard is locked, pressin " " for 5 seconds, when hearing one sound, the keyboard lock is open.
  • Page 17: Parameter Table

    4.3 Parameter table Digit meaning Range Default Adjust (yes/no) Return water temp. 81˚F Adjustable Setting (cooling model) Return water temp. 81˚F Adjustable Setting (heatin model) Return water temp. 81˚F Adjustable Setting (auto mode) Inlet water temp. True testing figure Outlet water temp. True testing figure Pipe temp.
  • Page 18: Appendix

     The operation pressure of the refrigerant system should only be serviced by a certified technician.  Check the power supply and cable connection often. Should the unit begin to operate abnormally switch it off and contact the qualified technician. ...
  • Page 19 Connections explanation : Symbol Meaning OUT1 Compressor of system 1 (220-230VAC) OUT2 Water pump (220-230VAC) OUT3 4way valve (220-230VAC) OUT4 High speed of fan motor (220-230VAC) OUT5 Low speed of fan motor (220-230VAC) AC-N Neutral wire NET GND 12V Wire controller DI01 GND On/Off Switch (input) (no use) DI02 GND...
  • Page 20: Appendix 3

    Earth line (AWG) (AWG) No more than 13A 13-18A 18-25A 25-30A 30-40A 40-55A 55-70A 2. Recommend circuit breaker to use UNIT BREAKER PASHW030-P-JI PASHW045-P-JI When the unit be installed at outdoor, please use the cable which can against UV. 6. APPENDIX...
  • Page 21 Appendix 3: Explosive view of the unit MODEL : PASHW030-P Code Parts name Code Parts name 32012-210246 Chassis 20000-360005 Water flow switch 32012-210245 Front panel 2000-2111 Water-proof box 20000-220188 Fan protection net 20000-220243 Handle 3500-2701 Axial fan 95005-310188 LED200 20000-330124...
  • Page 22 Appendix 3: Explosive view of the unit MODEL : PASHW045-P Code Parts name Code Parts name 20000-110038 Compressor 2001-3906 Three-seat connector 20000-140353 Needle valve 2000-3510 Compressor capacitor 3500-1401 Liquid-gas separator 2000-3524 Compressor capacitor 2004-1445 Filter 32009-210118 Cover of electrical box 2000-3603 Pressure switch 95005-310145 Main controller...
  • Page 23 Appendix 5: Circuit diagram of the unit PASHW030-P 6. APPENDIX...
  • Page 24 Appendix 6: Circuit diagram of the unit PASHW045-P...