INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
NOTE: Instructions must be posted in a prominent location. These instructions are for the user to follow
in the event that he/she detects the smell of gas. The information is also available from your local gas
company.
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing or serving this equipment.
Adequate clearances must be provided in front, rear and at sides of appliance for servicing. The
appliance area must be kept free and clear from combustibles. Remove any material or obstacles that
may obstruct the flow of combustion and ventilation air.
P/N 2412800000 REV. C 6/2011
Jade Range LLC, A Middleby Company
2650 Orbiter Ave.
Brea, CA 92821
Telephone (714) 961-2400
FAX (714) 961-2550
MODELS: JSR & JBR
FOR YOUR SAFETY
Do not store or use gasoline
or other flammable vapors or
liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
Open windows
Do not touch electric switches
Extinguish any open flame
Immediately call your gas
company
WARNING
RETAIN THIS MANUAL FOR FUTURE REFERENCE
Page 1

Advertisement

loading

Summary of Contents for Jade JSR

  • Page 1 Jade Range LLC, A Middleby Company 2650 Orbiter Ave. Brea, CA 92821 Telephone (714) 961-2400 FAX (714) 961-2550 SUPREME RANGE SERIES MODELS: JSR & JBR INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS NOTE: Instructions must be posted in a prominent location. These instructions are for the user to follow in the event that he/she detects the smell of gas.
  • Page 2 INSTALLATION AND GAS PIPING A qualified installer, service agency or gas supplier must perform installation and service. If equipped, the appliance is supplied with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 3 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig (3.45 kPa). Provisions shall be incorporated in the design of the kitchen to ensure an adequate supply of fresh air for proper combustion.
  • Page 4 The convection oven has a pilot re-ignition safety feature. This feature runs on 120V system using the pilot, thermocouple and Baso safety valve. To operate the pilot re-igniter, the master electric switch (toggle switch) located at the control panel must remain in “ON” position. If the pilot flame and oven burner flames are extinguished by drafts or temporary loss of gas (less than 5 seconds) the pilot will attempt to re-ignite by sparking.
  • Page 5: Service And Maintenance

    toggle switch to “MANUAL”. This will allow blower to operate and disperse excess heat rapidly from oven cavity (usually seconds). When ready, place new product in oven, close door and flip blower switch back in the “AUTO” position. When the blower toggle switch is in the “AUTO” position, the blower will operate only with oven door closed.
  • Page 6: Repair Guidelines

    It is strongly suggested that a trained gas appliance service company examine the appliance at least yearly. REPAIR GUIDELINES All repair work must be completed by a licensed, trained service person experienced in commercial gas food service equipment. During any service function, the satisfactory operation of the automatic gas ignition system (pilot safety) should be verified.
  • Page 7 CAUTION: In the event of prolonged power failure, DO NOT attempt to operate appliance. This appliance is serviceable to the front. It is suggested to provide at least 36 inches to the front of the appliance for servicing and for proper operation. When the appliance is equipped with casters, the installation shall be made with a connector that complies with the standard for Connectors for Movable Gas Appliances, ANSIZ21.69-1987, and Addenda, Z21.691989, and a quick-disconnect device that complies with the Standard for...