SENDO ECONOMY Instruction Manual

Digital blood pressure monitor

Advertisement

Quick Links

TM
E C O N O M Y
Digital blood pressure monitor
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECONOMY and is the answer not in the manual?

Questions and answers

Summary of Contents for SENDO ECONOMY

  • Page 1 E C O N O M Y Digital blood pressure monitor INSTRUCTION MANUAL...
  • Page 2 Introduction Thank you for purchasing a state-of-the-art Sendo blood pressure monitor. Sendo will give you years of accurate measurements, if it is used properly. We are always ready to provide help on our telephone lines for your country. 5 years guarantee Please read carefully the instructions before using this blood pressure monitor.
  • Page 3: Installing / Changing The Batteries

    Installing / Changing the Batteries Remove the battery cover. Remove the used battery and insert new battery into the battery compartment as shown, taking care that the polarities (+) and (-) are correct. Replace the battery cover. Use only R6P, LR6 or AA batteries. Connecting the Air Hose Insert the air connector plug into the air socket rmly.
  • Page 4 Measurement Sit comfortably in a chair with your feet at on the oor. Place your left arm on a table at a slight angle. Wrap the cu around the upper Arm Cu arm, about 2 - 3 cm above the elbow, as shown.
  • Page 5 START button Pres the START button. The average blood pressures and last data number are displayed brie y. When ashing and the mark , is displayed the device is ready for measurement. Note: If the mark , is displayed , the cu has air trapped in it.
  • Page 6 When the measurement is complete, the buzzer sounds and the mark is displayed. The systolic and diastolic pressure readings and pulse rate are displayed and stored. Press the exhaust valve button to completely release air from the cu . Press the START button to turn the power o . Automatic power-o function: If the device START button is left on after a measurement, it will turn o...
  • Page 7: How To Take Proper Measurements

    How to Take Proper Measurements For the most accurate blood pressure measurement:  Sit down in a comfortable position. Place the arm to be used for the measure- ment on a table or other support so that the center of the cu will be at the same height as your heart.
  • Page 8: About Memory

    About Memory The device automatically stores up to thirty blood pressure and pulse measure- ments in memory. Data stored in memory are assigned a data number in the order of the newest to the oldest. The oldest data displays as "n01". The M symbol in the upper left corner of the display indicates that you are viewing previous data stored in memory.
  • Page 9: What Is An Irregular Heartbeat

    *Arm size: The circumference at the biceps. What is an irregular heartbeat Sendo Economy provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is de ned as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement.
  • Page 10 Symbols Function / Meaning Recommended Action Standby and Turn the device on. Battery installation guide Direct current Serial number Type BF: Device, cu and tubing are designed to provide special protection against electrical shocks. The indicator that appears while measurement is in Measurement is in progress.
  • Page 11 WHO Classi cation Indicator Each six segments of the bar indicator correspond to the WHO blood pressure classi cation described on the next page. WHO Classi cation Indicator Severe hypertension Moderate hypertension Mild hypertnsion High normal Normal Optimal Example: Moderate Mild High hypertension...
  • Page 12: Blood Pressure Variations

    What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts. Diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg). One's natural blood pressure is represented by the fundamental pressure, which is measured rst thing in the morning while one is still at rest and before eating.
  • Page 13: Troubleshooting

    Troubleshooting Problem Possible Reason Recommended Action Nothing appears Batteries are drained. Replace all batteries with new ones. on the display, even when the Battery terminals are not in Reinstall the batteries with negative power is turned on. the correct position. and positive terminals matching those indicated on the battery compartment.
  • Page 14: Technical Data

    Storage condition Dimensions Approx. 81 mm (width) x 54 mm (height) x 105 (depth) mm Weight Approx. 260 g, excluding the batteries Note: Speci cations are subject to change without prior notice. EMC Table information is listed on our website: www.unicoms.com/sendo-emc...
  • Page 15 Guarantee As long as the instructions are followed your Sendo device should last for long years. In the event your Sendo monitor fails to operate due to manufacturing or materials related defects, we will repair it free of charge for the period of the guarantee.

Table of Contents