Heating Element - Waiwela MiniTank WM-1.0 Installation And Operating Instruction Manual

Electric mini tank – water heaters
Table of Contents

Advertisement

Resetting the high limit switch :
For various reasons the high limit safety shut off switch will occasionally shut the water heater down. This
shut down will occur when water temperatures exceed 190°F. Power is automatically turned off to the
heating element. The shut off device may activate as a result of a power outage or an electrical storm.
Note
: Do not attempt to reset the high limit switch without first allowing the water heater to cool down the
high temperature water inside the heater.
Warning
: Do not tamper with the reset button to override overheating shut down.
1. Turn off the power switch and unplug the water heater from the electric outlet.
2. Drain and remove the water heater. (see page 12)
3. Remove six screws retaining the bottom panel of the water heater and remove the panel.
Locate the high limit reset button.
4. Depress the small red button in the center of the junction box, replace the bottom panel and
place the water heater back into service.
Note
: A lower temperature setting saves energy and reduces the risk of scalding.
Caution
: Call a technician if the high limit needs to be reset frequently.
Page 14
High Limit Reset Button

Heating Element

Advertisement

Table of Contents
loading

Table of Contents